seconds. It indicates the detector is under normal operation.  When Smoke 
Detector senses smoke and simultaneously sounds an audible alarm, the red 
LED will flash frequently, once 0.67 seconds.    If the detector does not sound 
when testing, the battery must be replaced.   

 

WARNING:

 Never use an open flame to test your detector.    You may set fire to 

damage the detector, as well as your home. 
 

WARNING

: When you are not testing the unit and the alarm horn sounds a loud 

continuous sound, this means the detector has sensed smoke or combustion 
particles in the air.  Be sure that the alarm horn is a warning of a possible 
serious situation, which requires your immediate attention. 

 
Programming 

 

1. Z-Wave’s Group (Association Command Class Version 2)

 

 
The Smoke Detector supports one association group with five nodes.    This has 
the effect that when the detector is triggered, all devices associated with the 
detector will receive the relevant reports.    There are two main kinds of reports: 
ALARM_REPORT and SENSOR_ALARM_REPORT.  Please refer to the 
sections below for more details on the reports that the detector will emit when 
event occurs.   
 
1.1 POWER_APPLIED command 
 
The Smoke Detector will send ALARM_REPORT command to the nodes of 
Grouping 1 to inform the devices that the detector is powered up. 
   

ALARM_REPORT Command: 

[Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01] 

 
1.2 Smoke Event Report 
 
Once the detector has been triggered by smoke, the detector will send 
SENSOR_ALARM_REPORT (Sensor State = 0xFF) to the nodes of Grouping 1 
to inform them there is a smoke event; wait till the smoke is discharged, 
SENSOR_ALARM_REPORT (Sensor State = 0x00) will be sent to the 
associated devices. 
 

SENSOR_ALARM_REPORT 
 
Event Present: 

[Command Class Sensor Alarm, Sensor Alarm Report, Sensor Type 
Smoke Alarm State = 255 (0 x FF), Seconds = 0x00] 

 
Event Clear: 

[Command Class Sensor Alarm, Sensor Alarm Report, Sensor Type 
Smoke Alarm State = 0, Seconds = 0x00] 

 
1.3 Tamper Trigger Report 
 
When the tamper is triggered (that is, the detector is opened with tamper switch 
being released), the detector will emit ALARM_REPORT command to the 
nodes of Grouping 1. 
   

ALARM_REPORT Command: 

[Command Class Alarm, Alarm Type = 0x01, Alarm Level = 17(0x11)] 

 
Note:

 If you press test button under low battery status while tamper switch is 

released, the status LED will flash once. 
 
1.4 Low Battery Report 
 
When the battery level of the detector drops to an unacceptable level, the 
detector will sound once every 30 seconds and send BATTERY_REPORT 
command to the nodes of Grouping 1 once per hour. 
 

BATTERY_REPORT Command: 

[Command Class Alarm, Alarm Type = 0x01, Alarm Level = 255(0xFF)] 

 
The users can also enquire the battery status of the detector by sending 
BATTERY_ GET command via controller, however, this procedure can only be 
done during 5-second time allowance after the tamper switch/detector being 
triggered or 10 minutes wakeup time when power is first applied.  Once the 
detector receives the command, it will return BATTERY_REPORT command. 
 

BATTERY_REPORT Command: 

[Command Class Battery, Battery Report, Battery Level = 20%-100%] 

 
If it displays with a message of “Battery Level = 255 (0xFF)”, it implies that the 
detector is at low battery status. Please replace the batteries as soon as 
possible. 

Summary of Contents for SF812

Page 1: ...power is applied its LED flashes on and off alternately and repeatedly for 4 minutes which implies that it has not been assigned a node ID and cannot work with Z Wave enabled devices Please get famil...

Page 2: ...e for complete fire detection systems for places where many people live or work such as hotels or motels The same is true of dormitories hospitals nursing homes or group homes of any kind even if they...

Page 3: ...ticles in normal air flow paths is graphically shown in FIGURE 6 which indicates the correct and incorrect smoke detector locations concerning this problem 4 In damp or very humid areas or near bathro...

Page 4: ...plaster dust on it when you drill holes for mounting 6 Using the two screws and plastic wall plugs all supplied attach the bracket to the wall 7 Line up the slot of the bracket and the detector Push...

Page 5: ...of Grouping 1 to inform them there is a smoke event wait till the smoke is discharged SENSOR_ALARM_REPORT Sensor State 0x00 will be sent to the associated devices SENSOR_ALARM_REPORT Event Present Co...

Page 6: ...meters line of sight indoor ZDK Version V5 02 Specifications are subject to change without notice A501111353R01 Federal Communication Commission Interference Statement This equipment has been tested a...

Page 7: ...ing the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health...

Reviews: