Z-Wave SD-100Z User Manual Download Page 2

 

7.  If several windows need to be protected, adopt the wire according to the 

specifications as mentioned below. This should be wired to the terminal block 

provided in the battery compartment in series connection. The wired contact 

should be connected using two core (24AWG) wire of maximum length 4m. 

 

A cable entry cut-out is available and adjacent to the terminal block.

 

 

 

 

 

 

 

 

 

 

 

Internal connection   

External wired connection 

 

Choose either the internal or external wired connection, both of which types cannot 

be in existence at the same time. 

Note: 

After removing batteries, wait for 5 seconds to refit batteries. 

 

Operation 

1.  With the tamper switch not being pressed, the unit enters test mode, which 

allows the user to make a test. Detach the magnet from the Sensor, the red 

indicator LED on the Sensor will illuminate and the load or the lamp plugged into 

the On/Off Module HSS-A10, Lamp Module HSS-A20 will turn ON. It implies that 

the unit is working properly. 

Close the door/window by replacing the magnet to the Sensor will turn OFF the 

load or the lamp plugged into the On/Off Module HSS-A10, Lamp Module 

HSS-A20 and the red indicator LED on the connected load or lamp will be off too.   

2.  When the tamper switch is pressed, the unit enters normal mode. Open the 

door/window to detach the magnet from the Sensor will turn ON the load or the 

lamp plugged into the On/Off Module HSS-A10, Lamp Module HSS-A20.   

Close the door/window by replacing the magnet to the Sensor will turn OFF the 

load or the lamp plugged into the On/Off Module HSS-A10, Lamp Module 

HSS-A20.   

In normal mode with the tamper switch being pressed, the red indicator LED on 

the Sensor will not illuminate to conserve battery life when the sensor is triggered, 

(unless the battery is low).   

3.  By pressing the tamper switch for more than 5 seconds, and then release it. The 

Sensor will send an alarm command 

(ALARM_REPORT, Alarm Type == 0x01, 

Alarm Level == 0x11) 

to the module, of which load or the lamp plugged into the 

On/Off Module HSS-A10 or Lamp Module HSS-A20 will flash for 10 seconds.   

 

Advanced Operation 

 

The following information is for someone that has some experience setting up a 

Z-Wave system or someone that has computer software running a Z-Wave 

controller.   

Enabling/Disabling Power Saving Function (for testing) 

When the magnet is parted or closed from the Sensor for 10 seconds, the SD-100Z 

will enter the power saving mode. It can be disabled or enabled power saving 

function by setting Configuration Parameter # 3. 

This parameter can be configured with the value of 0 through 127, where 0 means 

power saving being enabled and others mean power saving being disabled. 

PS: As long as the batteries have been refitted, the Sensor will enable the power 

saving function automatically. 

Configuring the OFF Delay 

The Configuration parameter that can be used to adjust the amount of delay before 

the OFF command is transmitted is Configuration Parameter # 2. This parameter can 