Dimensions (L*W*H) 

80 x 80 x 40.5 mm 

*Specification is subjective to change without prior notice. 

Regulatory Compliance 

CE Caution 

Electromagnetic compatibility and Radio spectrum Matters (ERM); Short 
Range Devices (SRD); Radio equipment to be used in the 25 MHz to 1,000 
MHz frequency range with power levels ranging up to 500 mW; Part 2: 
Harmonized EN covering essential requirements under article 3.2 of the 
R&TTE Directive. 

FCC Caution 

This device complies with Part 15 of the FCC rules standard. Operation is 
subject to the following two conditions: 
1.

 

This device may not cause harmful interference, and  

2.

 

This  device  must  accept  any  interference  received,  including 
interference that may cause undesired operation. 

Any  changes  or  modifications  not  expressly  approved  by  the  party 
responsible for compliance could void the authority to operate equipment. 
This  device  and  its  antenna  must  not  be  co-located  or  operating  in 
conjunction  with  any  other  antenna  or  transmitter.  This  equipment 
complies with FCC radiation exposure limits set forth for an uncontrolled 
environment.  This  equipment  should  be  installed  and  operated  with 
minimum  distance  20cm  between  the  radiator  &  your  body.  This 
equipment has been tested and found to comply with the limits for a Class 
B  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are 
designed to provide reasonable protection against harmful interference in 
a residential  installation. This equipment generates, uses and can radiate 
radio frequency energy and,  if not installed and  used in accordance with 
the instructions, may cause harmful interference to radio communications. 
However,  there  is  no  guarantee  that  interference  will  not  occur  in  a 
particular installation. If this equipment does cause harmful interference to 
radio  or  television  reception,  which  can  be  determined  by  turning  the 
equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the 
interference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to 
which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

WEEE Information 

For  EU  (European  Union)  member  users:  According  to  the  WEEE  (Waste 
electrical  and  electronic  equipment)  Directive,  do  not  dispose  of  this 
product  as  household  waste  or  commercial  waste.  Waste  electrical  and 
electronic  equipment  should  be  appropriately  collected  and  recycled  as 
required by practices established for your country. 
For  information  on  recycling  of  this  product,  please  contact  your  local 
authorities, your household waste disposal service or the shop where you 
purchased the product 

Z-Wave Plus 

This  product  can  be  included  and  operated  in  any  Z-Wave  network  with 
other  Z-Wave  certified  devices  from  other  manufacturers  and/or  other 
applications. All non-battery operated nodes within the network will act as 
repeaters regardless of vendor to increase reliability of the network. 
This  device  must  be  used  in  conjunction  with  a  Security  Enabled  Z-Wave 
Controller in order to fully utilize all implemented functions. 
This  device  is  a  security  enabled  Z-Wave  Plus  product  that  is  able  to  use 
encrypted  Z-Wave  Plus  messages  to  communicate  to  other  security 
enabled  Z-Wave  Plus  products.  Note:  A  "Security  Enable  Z-Wave 
Controller" must be used in order to fully utilize this function. 

Security S2 

Security  S2  is  supported  with  the  Authenticated  and  UnAuthenticated 
levels  of  security.  The  Authenticated  level  requires  the  user  to  enter  the 
PIN  code  or  QR  code  printed  on  the  box  of  the  in  wall  switch.  The 
UnAuthenticated level does not require the PIN code. Both security levels 
will encrypt nearly all communication using AES-128 encryption to ensure 
reliable and secure communication. 

SmartStart  

SmartStart  enabled  products  can  be  added  into  a  Z-Wave  network  by 
scanning  the  Z-Wave  QR  Code  present  on  the  product  with  a  controller 
providing  SmartStart  inclusion.  No  further  action  is  required  and  the 
SmartStart product will be added automatically within 10 minutes of being 
switched on in the network vicinity. The pin code is printed on the back of 
device along with the QR code. Simply enter the PIN code or scan the QR 
code with a compatible device. Each QR code  is  unique for every device. 
SmartStart uses the latest Security S2 encryption technology for all  radio 
communication.  It  is  completely  backwards  compatible  with  non-
SmartStart systems if your home automation system doesn’t support it yet. 
About Pin code or QR code example: 

 

 
Please save the QR code or PIN code carefully.  
If both the DSK representation on the product and any DSK provided in the 
product packaging were to fade, rub off, or be lost, the device would not 
be able to be added to a Z-Wave network. 
 

 

 
 