Battery CC(V1)
The Battery Get request can be used to get the status of the battery.
When battery level is low a battery warning is sent to the controller.
Door Lock(V4)
- Door Lock Operation is used to lock and unlock this product.
1) To Lock : Sending command class = COMMAND_CLASS_DOOR_LOCK, command =
DOOR_LOCK_OPERATION_SET, mode = 0xFF (DOOR_SECURED) or BASIC_SET value 0xFF will lock
the door. Notification Type Access Control, Event 0x03 (RF lock operation) is sent to the Lifeline
and then one second later, a Door Lock Operation Report is sent to the Lifeline.
2) To Unlock: Sending command class = COMMAND_CLASS_DOOR_LOCK, command =
DOOR_LOCK_OPERATION_SET, mode = 0x00 (DOOR_UNSECURED) or BASIC_SET value 0x00 will
unlock the door. Notification Type Access Control, Event 0x04 (RF unlock operation) is sent to the
Lifeline and then one second later, a Door Lock Operation Report is sent to the Lifeline.
- See table to see how the Door Lock Mode parameter affects the lock.
Secured
Unsecured
Door Lock Mode
0xFF
0x00
In a Door Lock Operation Report the GKBC-3100Z will report.
Door Status
Unlocked
Locked
Door Lock Mode
0x00
0xFF
Handles
0x00
0x00
Door Condition
Bit 0 : Door
0 : Open, 1 : Close
Bit 1 : Deadbolt
0 : Locked, 1 : Unlocked
Lock Timeout Minutes
0xFE
Lock Timeout Seconds
0xFE
Firmware Update Meta Data(V5)
The GKBC-3100Z supports firmware update of the Z-Wave module over the air.
The firmware upgrade takes ~20 min with S0 and ~20 min with S2
Firmware ID = 0x0102.
Firmware 0 ID = 0x0101.