MANUAL FOR OUTDOOR PASSIVE INFRARED DETECTOR
2.Installation setting
3.Connecting
power
4.The
significance
of
indicator
5.Setting the working states
Let
the
indicator
side
up
,
the
bottom
flat
against
the
wall
,
fix
the
back
slide
board
with
screws
,
keep
the
distance
between
detector
and
floor
about
2
.
0
~
2
.
5m
.
If
the
detector
needs
to
adjust
angle
,
you
can
choose
SKY
-
U
full
-
direction
bracket
.
Notes
:
I.the detection range will change with the detection angle
and height
II
.
the connected line should come out from the bottom of
the detector
.
The wiring hole port needs
to
put
waterproof
ring
.
The
detector
enter
into
normal
working
status
,
after
30
seconds
self
-
test
.
Detector
detects
intruder
.
The
red
LED
lights
for
3
seconds
.
The
detector
alarms
.
alarms
after
dusk
.
When
the
button
points
to
NIGHT
mode
,
it
means
the
detector
alarms
in
the
evening
.
6.Setting infrared pulse count jumper
I. The two sets of infrared sensitivity jumper 1&2
generally is set the same pulse count.
when
jumper
connects
the
2
position
,
the
pulse
count
is
2
.(
defaulted
2
)
II. Setting relay jumper
The
defaulted
setting
is
3s
.
When
the
relay
jumper
is
set
to
3s
,
detector
alarms
,
relay’movement keeps
3
seconds;When
the
relay
jumper
is
set
to
20s
,
detector
alarms
,
relay’movement
When
the
LED
jumper
connects
and
alarm
,
red
LED
indicator
lights;When
the
LED
jumper disconnects
and
does
not
alarm
,
red
LED
indicator
does
not
light
.
7.Wiring diagram
In the strong EMI environment
,
increase the number of
pulse
counts and decrease the detection sensitivity
.
The surface of installation needs to be strong
,
and stable
,
without
rocking
.
I.Setting infrared sensitivity jumper
The
two
sets
of
infrared
sensitivity
jumper
1
&
2
generally
is
set
in
the
same
location
.(
the defaulted
setting
is
6
-~
12m
)
Jumper
connects
9
-
18M
position
.
The
detector’s
sensitivity
is
9
-
18M
.
Jumper
connects
6
-
12M
position
.
The
detector’s
sensitivity
is
6
-
12M
.
Jumper
connects
5
-
9M
position
.
The
detector’s
sensitivity
is
5
-
9M
.
Jumper
connects 3
-
6M
position
.
The
detector’s
sensitivity
is3
-
6M
.
II. Adjust the detection mode
When
the
button
points
to
DAY
mode
,
it
means
all
-
day
alarm
mode
When
the
button
points
to
NORMAL
mode
,
it
means
the
detector
when
jumper
connects
the
1
position
,
the
pulse
count
is
1
.
connect
disconnect
keeps
20 seconds
Intrusion
alarm off
General electomagnetlc relay output
Electronic solid-state relay output
Intrusion
alarm
Intrusion alarm
connected
Tamper
alarm
Tamper
alarm