Charging Pile Instructions-V2.0
8
modulated (RS)
9
Radio-frequency continuous conducted (CS)
Pass
10
Power-frequency magnetic fields
Pass
11
Fast transients (EFT)
Pass
12
Surge
Pass
13
Electrostatic discharges (ESD)
Pass
14
Voltage dips and interruptions
Pass
Note
:
Add accessories to pass EMC test
5.5 Safety features
No.
Item
Technical
requirements
Unit
Remark
1
Impulse
withstand
voltage
Input-Earth
≤10
mA
2.8kVDC
Output-Earth
≤10
mA
3.5kVDC
Input -Output
≤10
mA
3.5kVDC
2
Insulation
resistance
Input-Earth
≥
10
MΩ
500VDC
Output-Earth
≥
10
MΩ
1000VDC
Input -Output
≥
10
MΩ
1000VDC
3
Dielectric
strength
Input-Earth
No breakdown
and insulation
damage
-
Thunder electric wave
±
6KV
Output-Earth
Input -Output
4
Grounding
impedance
The maximum resistance is under
1000 mΩ between the charging
machine and the site.
mΩ
5
≥
14
mm
6
Creepage
distance
≥
16
mm
7
Touch current
≤
3.5
mA
8
RCD
YES
-