YUSHI LM-100 Operating Manual Download Page 6

No.

Code

Model

Special

Support Ring

Sketch

Remark

1

03-03.7

Z10-15

Measure outside the cylindrical
surface R10~R15

2

03-03.8

Z14.5-30

Measure outside the cylindrical
surface R14.5~R30

3

03-03.9

Z25-50

Measure outside the cylindrical
surface R25~R50

4

03-03.10

HZ11-13

Measure inside the cylindrical
surface R11~R13

5

03-03.11

HZ12.5-17

Measure inside the cylindrical
surface R12.5~R17

6

03-03.12

HZ16.5-30

Measure inside the cylindrical
surface R16.5~R30

7

03-03.13

K10-15

Measure outside the spherical
surface SR10~SR15

8

03-03.14

K14.5-30

Measure outside the spherical
surface SR14.5~SR30

9

03-03.15

HK11-13

Measure inside the spherical
surface SR11~SR13

10

03-03.16

HK12.5-17

Measure outside the spherical
surface SR12.5~SR17

11

03-03.17

HK16.5-30

Measure outside the spherical
surface SR16.5~SR30

12

03-03.18

UN

Measure outside the cylindrical
surface

adjustable radius R10~

Table 2.2

3. Functions and Applications

3.1 Technical Specifications

Measuring Method: Leeb Hardness Testing method
Hardness Scale: HL, HB, HRB,HRC,HV,HS, σ

b.

Measuring Range : HLD (200-960), HRC

19.8-68.5

, HB

30-651

, HV

80-976

, HS

26.4-99.5

HRB

13.5-100 ), σ

b

(375-2639).

Impact Device: D type

impact device

(Standard); Optional

C/G/DC/DL/D+15
Accuracy: ±6HLD (HLD=800), Repeatability 6HLD (HLD=800)
Measuring Direction: Vertically downward, inclined downward, Level,
inclined upward, vertically upward
Material : Steel & Cast Steel, Stainless Steel, GC IRON, NC IRON, Cast
Aluminum Alloy, Copper-Zinc Alloy, Copper-Tin Alloy, Brass,

Forging Steel.

Resolution: 1HL, 1HV, 1HB, 0.1HRB, 0.1HRC, 0.1HS
Display: High Contrast Segment Liquid Crystal Display (LED Backlight)
Memory: 100 groups ( impact times 1-7 )
Communication Port : USB 2.0 (Standard), and Bluetooth (Optional)
Printer: Thermal Printer with bluetooth (Optional)
Power: 2 AA batteries,1.5V
Working Temperature: -10

~ +50

Size: 153 × 76×37 (mm) (H×W×D)
Weight: 280g ( include battery)
Standard: GB/T 17394-2014, ASTM A956

3.2 Applications

Installed machinery and Permanent assembly parts
Mould cavity
Heavy workpieces
Failure analysis of pressure vessel, turbine and other equipments
Small test area
The production line of Bearings and other parts
Distinguish the material of the metal material warehouse

4 .Pre-Treatment of Workpiece

4.1 Workpiece Requirements

4.1.1 Surface Roughness requirements

Surface roughness is an important requirement for the surface of the test
piece, it should be smooth and no oil, or will cause measurement errors.
The surface roughness of the test piece should not exceed the value in the
bellowing table:

7

8

8

Summary of Contents for LM-100

Page 1: ...Leeb Hardness Tester LM100 Operating Manual YUSHI INSTRUMENTS...

Page 2: ...ss Requirements 9 4 1 3 Surface Hardened Layer Thickness 9 4 1 4 Curved Surface Requirement 9 4 2 Support of Test Piece 10 5 Operation 10 5 1 Display 10 5 2 Keyboard 11 5 3 Turn on the Instrument 11 5...

Page 3: ...uce directly proportional voltage with the impact velocity The Leeb hardness values are calculated by the following formula HL 1000 Vb Va In Which HL Leeb hardness values Vb the voltage produced durin...

Page 4: ...7 2g 7 8g 3 0g 20 0g 5 5g Test Tip Hardness 1600HV 1600HV 1600HV 1600HV 5000HV Test Tip Diameter 3mm 3mm 3mm 5mm 3mm Test Tip Material Tungsten Carbide Tungsten Carbide Tungsten Carbide Tungsten Carbi...

Page 5: ...7 m 10 m Impact Device Applicable Scope DC Used for very confined spaces such as holes cylinders internal measurement DL Used for extremely confined spaces D 15 Used for measuring in grooves recessed...

Page 6: ...D type impact device Standard Optional C G DC DL D 15 Accuracy 6HLD HLD 800 Repeatability 6HLD HLD 800 Measuring Direction Vertically downward inclined downward Level inclined upward vertically upwar...

Page 7: ...ce to be tested is smaller than 30mm D DC D 15 C E and DL type of impact device and smaller than 50mm G type of impact device the small support ring or the special support rings should be selected 4 2...

Page 8: ...e button to select the probes 5 4 4 Impact Direction Press DIR button to select impact direction Figure 5 4 5 4 5 Impact Times Press TIME button to set the impact times from 1 7 which will calculate t...

Page 9: ...7 Data Save and Read Setting 5 7 1 Storage Testing Result Press MEM storage button to set the saving function the S symbol will be shown on the display The tester will save the testing results automat...

Page 10: ...is will cause the measuring error so we design a calibration procedure of using the standard testing block to calibrate Press up and down button at the same time after the power on then the tester wil...

Reviews: