External Control Device Setup
39
EN
OK Acknowledgement
* The Monitor transmits ACK(acknowledgement) based on
this format when receiving normal data. At this time, if
the data is data read mode, it indicates present status
data. If the data is data write mode, it returns the data of
the PC computer.
[F7][Command][SetID][Data][CS][7F]
Error Acknowledgment
* The Monitor transmits ACK(acknowledgement) based
on this format when receiving abnormal data from non-
viable function or communication errors.
[F7][Command][SetID][FF][CS][7F]
Transmission
* [F6]
: Start of Communication
* [Command]
: Command set
* [Set ID]
: You can adjust the set ID to choose
desired monitor ID number in SETUP
menu.
See previous page. Adjustment range
is 1~99.
When selecting set ID '0', every
* [DATA]
: To transmit command data.
Transmit 'FF' data to read status of
command.
* [CS] :
Check
Sum
ASCII code ‘0x0D’
* [6F]
: End of Communication
[F6][Command][SetID][Data][CS][6F]
Transmission / Receiving Protocol
01. Power
G
To control Power On/Off of the set
Transmission
Data 0 : Power Off
1 : Power On
[F6][01][SetID][Data][CS][6F]
OK Acknowledgement
[F7][01][SetID][Data][CS][7F]
G
To show Power On/Off
Transmission
[F6][01][SetID][FF][CS][6F]
[F7][01][SetID][Data][CS][7F]
OK Acknowledgement
Data 0 : Off
1 : On
* In like manner, if other functions transmit 'FF' data based on this
format, Acknowledgement data feed back presents status about
each function.
02. Volume Mute
G
To control volume mute On/Off of the set
Transmission
Data 0 : Volume Mute Off (Volume On)
1 : Volume Mute On (Volume Off)
[F6][02][SetID][Data][CS][6F]
OK Acknowledgement
[F7][02][SetID][Data][CS][7F]
Summary of Contents for LC-40IEB3