MAINTENANCE

 

(cont) 

 
CLEANING THE GLASS 

 
The glass may be cleaned with damp paper towels. Ceramic glass cook top cleaner may also be 
used. The inside of the glass may also need cleaning from time to time (refer page 11 for glass 
door removal information). 

Note: Never clean the glass when it is hot. Do not use abrasive cleaners on the glass. 
 

CLEANING THE CHASSIS 

 

The enamelled chassis may need cleaning from time to time to remove a white film (refer page 
11 for glass door removal information). The chassis is enamelled so a wipe over with a damp 
cloth, when the chassis is cool, will be sufficient. 

 

 

REPLACING THE DOOR ROPE (GASKET) 

                                                                                          
The YUNCA 

LEEDZ

 (Fuzzy Logic control) has a 10mm fibreglass gasket (1608LF) surrounding 

the front and side glass. Should it ever need replacement, use only the replacement gasket that 
is available from your YUNCA dealer.  

 
Procedure: 

1. Remove the front door as described on previous page. 
 
2. Remove the existing gasket and clean the channel of all loose material. 
  
3. Lay a thin bed of gasket cement (PVA glue) around the length of the channel 
 
4. Lay the gasket in the channel ensuring the gasket is not stretched. 
 
5. Replace the door carefully to avoid dislodging the gasket. 
 
 

BATTERY BACK UP REPLACEMENT 

 
Your 

YUNCA GAS LEEDZ

 (Fuzzy Logic control) will operate (WITHOUT FAN BOOST) if power 

is not available for any reason.  
 
Two “D” size batteries are located on the right side plinth panel. Unclip the cover from the top, (it 
is hinged at the base), and remove the batteries, replacing with fresh ones. The cover shows the 
polarity of the batteries. 
 
Take care when working near an operating heater, it will be hot!  
 
Batteries will operate the back up system for about 200 hours. Fan boost cannot run on battery 
back up.  
 

Always  ensure  the  batteries  are  fresh

,  and  consider  changing  these  once a  year  (end  of 

summer daylight saving time, when you change your smoke alarm batteries, is a good routine. 
You will have fresh batteries for the coming winter). Batteries left too long may leak and damage 
the contacts, so take note of the recommendation to change them annually. 
 

Summary of Contents for LEEDZ

Page 1: ...Fuzzy Feb 2010 Page 1 of 19 LEEDZ FUZZY LOGIC control FREESTANDING GAS HEATER FEBRUARY 2010 INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION These instructions should be stored in a convenient...

Page 2: ...CONTROL AUTO TIMER 8 10 MANUAL CONTROL OPERATION 11 MAINTENANCE DOOR REMOVAL GLASS REPLACEMENT 11 GLASS CLEANING DOOR ROPE REPLACEMENT 12 BATTERY BACK UP 12 SERVICE INSPECTION AND CLEANING 13 GAS CON...

Page 3: ...k controls for added peace of mind We highly recommend the use of the two speed fan boost on the fire for greater heating efficiency Should power not be available for any reason battery back up throug...

Page 4: ...fitted When the appropriate position has been selected the unit must be bolted to the floor to ensure that the unit remains upright in the event of an earthquake or similar Fig 1 below If the heater...

Page 5: ...case the length of the flue shall not be less than 3 metres from the top of the appliance flue spigot 2 When loose fill insulation is used in the adjacent ceiling space maintain clearance between the...

Page 6: ...below Fig 3 and comply with NZS 5261 AG601 This is to ensure adequate air circulation around the heater and avoid heat damage to wall coverings Note If walled surface is non combustible i e brick or...

Page 7: ...d be tested for leaks before operating the heater TO CHECK GAS PRESSURE 1 Remove the front plinth cover two screws at top of cover 2 Test point can be seen on the left side of the control box 3 Slacke...

Page 8: ...Revised 04 08 10 YUNCA Leedz FS Fuzzy Feb 2010 Page 8 of 19 LEEDZ INFRA RED REMOTE CONTROL with AUTO TIMER N B DO NOT LEAVE THE REMOTE CONTROL ON TOP OF YOUR FIRE...

Page 9: ...our Yunca Fuzzy Logic control fire HINT The two speed fan is designed to quickly transfer heat around the room and ensures the most economic gas use The three position switch HIGH OFF LOW is located o...

Page 10: ...ou will see the AUTO symbol display on the LCD screen of the remote control unit IMPORTANT Press AUTO SET button again to cancel the auto feature or the fire will continue to operate to the automatic...

Page 11: ...ove the front door as described above and place front down on a soft surface 2 Remove the two side glass retainers by taking out the three bolts in each one 3 Remove the bottom front glass retainer by...

Page 12: ...page 2 Remove the existing gasket and clean the channel of all loose material 3 Lay a thin bed of gasket cement PVA glue around the length of the channel 4 Lay the gasket in the channel ensuring the...

Page 13: ...g it up and out Brush it gently over a newspaper and carefully place it out of the way 3 The bark tray can be removed by lifting its feet over the bottom gasket retainer and pulling it straight out wi...

Page 14: ...1 Remove front cover 2 Disconnect the wiring from switch 3 The earth wire must be unplugged and the plastic conduit adaptor removed from its retaining bracket 4 Disconnect earth wire from control valv...

Page 15: ...to replace Pilot Set or drill the injector Nozzle diameter LPG 0 35 mm NG 0 55 mm Replace POSSIBLE CAUSE AC Power IS unplugged or loose or the fuse has a short Battery power is too low when using DC p...

Page 16: ...he terminals have loosened Valve M has a failure or Nozzle of Valve M is blocked Front Control Board has a failure Remote Control Unit has a failure The wire set has a failure or the terminals have lo...

Page 17: ...ition rocker switch 6699 Fan only unwired QLZ06 1200 A49 6624G Fan assembly complete 6611G Otago Bay Log Set assembly 6611C Logset twig 88 LFzR Right side panel State Colour 88 LFzL Left side panel St...

Page 18: ...r any other indirect incidental cause are not covered by this warranty This warranty is void if the recommended service schedule is not implemented and carried out by a suitably qualified person as su...

Page 19: ...urchased Installed By Date Designed and Manufactured by Yunca Gas Dunedin PO Box 500 DUNEDIN 9054 Telephone 03 488 4342 Email dunedin yunca co nz Cut along here This section must be completed and retu...

Reviews: