INSTRUCTIONS FOR INSTALLING
FIELD CONTROLS TYPE R-C
BAROMETRIC DRAFT CONTROL
DO NOT ATTACH DRAFT CONTROL TO TOP OR BOTTOM OF THE
FLUE PIPE, NOR IN A ROOM SEPARATED FROM THE FURNACE.
BEST LOCATION IS AS CLOSE TO FURNACE AS POSSIBLE.
PRE-MOUNTING SET UP INSTRUCTIONS
MAKE THE FOLLOWING ALTERATIONS BEFORE
MOUNTING CONTROL ON THE TEE
VERTICAL FLUE:
Adjustment weight must be in RIGHT HAND SLOT
(Marked “V”) in bracket on gate. See Fig. 7
The arrow on flap at bottom of gate must line up
with letter “V” on lower right part of gate. If it does
not, remove flap, turn over and snap on to gate
again.
Flap can be removed by inserting small screw
driver at the back side of the gate between the gate
and the flap, then pulling downward on flap.
HORIZONTAL FLUE:
Adjustment weight must be in LEFT HAND SLOT
(Marked “H”) in bracket on gate. See Fig. 8
The arrow on flap at bottom of gate must line up
with letter “H” on lower left part of gate. If it does
not, remove flap, turn over and snap on to gate
again.
Weight on “V”
side of bracket
Weight on “H”
side of bracket
IMPORTANT
A MANOMETER MUST BE USED TO
ACCURATELY ADJUST FLUE DRAFT
Installation
FIG. 7
FIG. 8
WARNING
NO DAMPER, HEAT SAVER, OR
AUTOMATIC VENT DAMPER DEVICE
SHOULD BE INSTALLED IN OR ON
SMOKE PIPE EXCEPT THE
BAROMETRIC DRAFT REGULATOR
Summary of Contents for SUPER JACK SJ125
Page 9: ...Furnace Features SJ125 3 1 2 4 5 6 7 8 9...
Page 11: ...Furnace Features BJ90 1 2 3 4 5 6 7 11...
Page 41: ...Notes...
Page 42: ...Exploded Views Parts List SUPER JACK SJ125 42...
Page 44: ...Exploded Views Parts List BIG JACK BJ90 44...
Page 48: ...Notes...
Page 49: ...Notes...
Page 50: ...Notes...
Page 51: ...Notes...