http://www.shooterready.com/mildot.swf
TECHNICAL INSPECTION
It is recommended to inspect the riflescope before every use. Make sure to check for the
following:
•
Visually inspect the unit is free from any physical damage; cracks, dents or signs of
corrosion disqualify it from proper use.
•
Check the sturdiness and proper fit of the mounting system.
•
Ensure the condition of the objective lens, eyepiece and the IR illuminator are free of
cracks, grease spots, dirt, water stains and other residue before use.
•
Visually inspect the condition of the battery and the battery compartment; the battery
should be free of electrolyte and oxidation residue, especially where the battery makes
contact with metal.
•
Verify the proper function of the following; selector switch (3), reticle brightness knob
(4), reticle selector button and the instant power-on button (11).
•
Verify the smoothness of the objective lens focusing mechanism (6), diopter focusing
knob (7) and the IR illuminator knob (8).
TECHNICAL MAINTENANCE
Technical maintenance should be done no less than twice a year, and is comprised in the
following steps:
•
Clean the outside metallic and plastic surfaces from dust, dirt and moisture; wipe the scope
with a soft cotton tissue, lightly coating it with gun oil or petroleum jelly.
•
Clean the battery compartment's electric contact points using an oil-free solvent.
•
Inspect the eyepiece lens, the objective lens and the IR illuminator and gently blow off any
dust and sand, and clean using lens cleaner and a soft cloth; see section entitled
“GUIDELINES FOR OPERATION”.
USING THE DIGITAL CAMERA ADAPTER
In order to conduct photo- and video recording please purchase a digital camera adapter accessory
(#29023). Secure your Phantom to the included Weaver rail, refer to the manual for the camera
adapter for further operation.
USING THE NVRS 2.5X50 ATTACHMENT
The NVRS 2.5x50 attachment (#29091) increases the magnification power of the 50mm
PHANTOM 1.7 times.
The attachment screws into the internal groove of the riflescope's objective lens; refer to the
instruction manual for the NVRS 2.5x50 when installing. A possible shift of the aiming point may
occur and, in that case, it is important to sight in the scope as previously described.
USING THE ADDITIONAL WEAVER RAIL
The scope has a built-in additional weaver rail mount (14) housed on the left portion of the body.
This will allow the mount of additional devices, such as:
•
The Yukon IR illuminator, with mount (#29072)
•
The Yukon NVRS directional microphone with adapter (#27022)
•
The Yukon laser sighting device (#27012)