CLM920_NC3_LTE Module hardware manual
Shanghai Yuge Information Technology co., LTD
- 68 -
normal
High
temperature
work
Temperature: 85
℃
Working mode: normal work
Test duration: 24 h
JESD22-A
108-C
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Temperature
cycle
High temperature: 85
℃
Low temperature:
–
40
℃
Working mode: normal work
Test duration: 30
Cycles;1 h+1h /cycle
JESD22-A
105-B
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Alternating
hot and
humid
High temperature: 55
℃
Low temperature: 25
℃
Humidity: 95%
±
3%
Working mode: normal work
Test duration: 6
Cycles;12 h+12
h/cycle
JESD22-A
101-B
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Temperature
shock
High temperature: 85
℃
Low temperature:
–
40oC
Temperature change time: < 30s
Working mode: no packaging, no
Power on, do not boot
Test duration: 100
Cycles;15 min+15
Min/cycle
JESD22-A
106-B
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Drop test
Height 0.8 m, 6 sides each time,
dropped to the horizontal marble
platform
Working mode: no packaging, no
Power on, do not boot
IEC60068
-2-32
Visual inspection: normal
Function check: normal
RF indicator check:
normal
Low
temperature
storage
Temperature:
–
40
℃
Working mode: no packaging, no
power, no boot
Test duration: 24 h
JESD22-A
119-C
Visual inspection: normal
Function check: normal
RF indicator check:
normal