Yudo ACT-D800 Instruction Manual Download Page 9

b. For the delay time, it count down and displays it in DEL display panel, and just after 

DEL time, it opens for OPEN time and it counts down from the OPEN set time and 
displays it in OPEN display panel.

把延迟的

DEL

时间倒数计秒

标在

DEL

表示窗口

DEL

时间完成后开始

OPEN

时间期间

,OPEN

间从设定值开始倒数计秒

并标示在

OPEN

显示窗口。

c. In case injection signal is off before delay time passed, it resets to set time. 

如在延迟时间或

OPEN

时间结束之前

注塑信号先结束

就开始设定时间初始化。

d. In case injection signal is off before open time passed, it resets to set time. 

OPEN

时间终止前注塑信号终止时往设定时间初始化

.

e. When injection signal is off, delay set time and open set time will be displayed                  

DEL display panel and OPEN display panel respectively.

注塑信号结束

,

延迟设定时间和

OPEN 

设定时间

就标示在

DEL 

显示窗口和

OPEN

显示窗口。

6

3

MODE   C       

模式

C     

INJECTION
SIGNAL

Del

1

Open

1

t1  

Signal On                                                       

t2  

Signal Off

MODE 

C

动作

Open

2

Del

2

T

Example 

a. In case injection signal=10sec, DEL time Del1=2sec, OPEN time Open1=4sec, and   

Del2=1sec and Open2=4Sec. then when injection signal comes on, after DEL time, it 
opens for OPEN time (4sec).

注塑时间

:10

, Del1

时间

: 2

, Open1

时间

: 3

秒,

Del2

时间

: 1

, Open2

时间

:4

秒。按到注塑信号

2

秒后

, GATE 

OPEN 

状态维持

3

秒输出动作自动关闭,然后保压

1

秒钟后,

GATE 

OPEN   

状态维持

4

秒钟后输出动作将自动关闭。

b. For the delay time, it count down and displays it in DEL display panel, and just after 

DEL1 time, it opens for OPEN1 time and it counts down from the OPEN1 set time and 
displays it in OPEN display panel.

把延迟的

DEL1

时间倒数计秒

标在

DEL

表示窗口

DEL1

时间完成后开始

OPEN1

时间

,OPEN1

间从设定值开始倒数计秒并标示在

OPEN

窗口输出动作。在

Open

时间完成后开始

Del2

时间,

Del2

时间从设定值开始倒数计秒,标在

DEL

表示窗口。在

DEL2

时间完成后开始

OPEN2

时间,

OPEN2

时间开始倒数,标在

OPEN

窗口并输出动作。

USER’S MANUAL

Summary of Contents for ACT-D800

Page 1: ...INSTRUCTION MANUAL TYPE ACT D800 Sequence Injection Controller Version 5 5 Sequence Injection Controller...

Page 2: ...splay 3 6 Output 3 7 Start to Run 4 8 Menu Setting 5 9 Mode Specification 7 10 System Application 8 11 Wiring Specification 9 Before using the product please read this instruction manual carefully to...

Page 3: ...lay unit Switch PCB 3 Central Processing Unit 1 S M P S To transform input AC220V to DC24V 1A DC5V 1A S M P S AC220V DC24V 1A DC5V 1A 2 M P U To control input output and display 3 RELAY Solenoid Valve...

Page 4: ...e gate selected GATE a To turn On Off time ON OFF 5 Display 1 Display delay time and open time of each gate in display panel GATE OPEN 2 Display LED on while each gate opens GATE OPEN LED 3 Display MO...

Page 5: ...nd open time value at each display panel GATE OPEN GATE 4 Switch between MODE A MODE B and gate off mode A mode B off A Press for 4 seconds a Buzzer rings and mode LED blinks MODE LED b MODE LED of 1s...

Page 6: ...a Buzzer rings and MODE LED Blinks MODE LED b Unl displays in DEL panel and 999 or 99 9 9 99 display in OPEN panel GATE LED Unl OPEN 999 99 9 9 99 c Switch units using d Move gate using GATE e Hit to...

Page 7: ...d Hit to save or keep idle for 4 seconds to automatic save 4 8 Set OPEN time OPEN Move using to get gate and its OPEN panel to confirm GATE OPEN a Right digit in OPEN panel blinks GATE OPEN b Set tim...

Page 8: ...passed injection signal is keeping on it opens and it counts up the open time and displays it in OPEN display panel OPEN e When injection signal is off delay set time will be display in DEL display pa...

Page 9: ...play panel and OPEN display panel respectively OPEN DEL OPEN 6 3 MODE C C INJECTION SIGNAL Del1 Open1 t1 Signal On t2 Signal Off MODE C Open2 Del2 T Example a In case injection signal 10sec DEL time D...

Page 10: ...ltage DC24V or AC220V in compliance with Solenoid valve DC24V AC220V b Display output voltage in DC24V LED or AC220V LED DC24V AC220V B Input ON OFF Indicator ON OFF a When input is on SIGNAL LED is o...

Page 11: ...ay Time t2 Injection time Gate Open Time T t 1 t 2 T t 1 t 2 Mode C Selecting mode C After the injection signal has been received the gate is closed during the DEL time t1 After the DEL time t1 has el...

Page 12: ...uct Open the gate A to fill the major portion of the molded part and then open the gate B to fill the short molded area of the component A B Application for Mode B In case that there is a wide differe...

Page 13: ...Connect AC220V using AC220V Solenoid Valve and DC24V Solenoid Valve to DC24V ACST600 3 JUMPER SETTING AC220V AC220V DC24V DC24V 11 Wiring Specification 10 SEQUENCE INJECTION CONTROLLER Input Output Ra...

Page 14: ...7 MENO 10...

Page 15: ...86 769 85394466 FAX 852 769 85394455 E MAIL yudo changan net YUDO WANCO SHUZHOU CO LTD TEL 86 512 65048882 FAX 86 512 65046886 E MAIL suzhou yudowanco com YUDO WANCO SHANGHAI OFFICE TEL 86 21 5059381...

Reviews: