SPTM-5V series 

 

4.  Connection – Power 

4.1 

Safety 
When installing a unit, please ensure to read and follow safety instructions.   

  When  installing  in  hazardous  and  explosive  gas  area,  conduit  tube  or  pressure-proof 

packing union must be used.   

  Please use ring-type rug to protect against vibration or any other external impact. 

  Please  use  twisted  cable  with  conductor  section  are  1.25mm

2

  and  that  is  suitable  for 

600V (complying to the conductor table of NEC Article 310.)  The outer diameter of the 
cable  should  be  between  6.35  ~  10mm.  Use  shield  wire  to  protect  against  electro-
magnetic field and noise.   

  Please  do  not  install  the  cable  near  high  noise  equipments,  such  as  high-capacity 

transformer or motor. 

4.2 

 

 
 
 

Summary of Contents for SPTM-5VL

Page 1: ...Smart Position Transmitter PRODUCT MANUAL SPTM 5V SERIES VERSION 1 01...

Page 2: ...tions 4 2 3 Label Description 4 2 4 Product Number 5 2 5 Product Specification 5 2 6 Parts and Assembly 6 2 7 Dimension SPTM 5VL 7 2 8 Dimension SPTM 5VR 7 3 Installation 8 3 1 Safety 8 3 2 SPTM 5VL I...

Page 3: ...ponsible for any damages caused by user s negligence Manufacturer will not be responsible for any damages or accidents as a result of any alteration or modification of the product and its parts If any...

Page 4: ...uilt micro processor which transmits DC 4 20mA signal according to changes in valve or damper position 2 2 Main Features and Functions Designed to be Ex ia IIC T6 explosion proof grades Economical pri...

Page 5: ...0 3 0 Output Signal 4 20mA DC Load Resistance Max 600 28V DC Supply Voltage 9 28V DC Noise Range 50mV p p Conduit Entry PF 1 2 G 1 2 Enclosure IP 67 Explosion Proof Ex ia IIC T6 KCs Ambient Temp Opera...

Page 6: ...6 SPTM 5V series 2 6 Parts and Assembly...

Page 7: ...7 SPTM 5V series 2 7 Dimension SPTM 5VL 2 8 Dimension SPTM 5VR...

Page 8: ...f the valve stroke Feedback lever connection with the pin of the actuator clamp should be installed in such a way that the valve stroke length coincides with the corresponding figure of mm marked on t...

Page 9: ...he connection pin at the number on the feedback lever which corresponds to the desired valve stroke To adjust mover the bracket or the connection pin or both 9 After installing the SPTM 5v operate the...

Page 10: ...ing type rug to protect against vibration or any other external impact Please use twisted cable with conductor section are 1 25mm2 and that is suitable for 600V complying to the conductor table of NEC...

Page 11: ...to output 12mA signal when the feedback lever is at 50 position In case of dislocation of the potentiometer please follow below procedure to re set the potentiometer Power must be turned off before ad...

Page 12: ...talled improperly please refer to the positioner s manual and re install the positioner C Set the positioner s zero and span Inaccurate zero and span setting can lower the accuracy and linearity D Che...

Reviews: