四 Troubleshooting guide
4.1 Introduction
Governor failure is usually caused by mechanical failure
of the installation or position control valve. Before adjusting
the position control valve or controller, carefully check all
electrical connections, power supplies, and valve flexibility.
Manually move the handle on the dial side of the position
control valve manually, from 0 ° to 75 ° without jamming. If a
stagnation occurs at a certain point, it will cause the engine
speed to be unstable when it is near this air supply position.
五 Position control valve parameters
Power supply 20 VDC
~
32 VDC (24 VDC nominal)
Output torque up to 5Nm
Output current 4A continuous; 10A peak, last 30 seconds
Operating temperature range
-
40
℃ ~ +
100
℃
Storage temperature range
-
55
℃ ~ +
125
℃
GJB150.16-1986 Environmental test method for military
equipment (shock test)
Vibration GJB150.16-1986 Environmental test method for
military equipment (vibration test)
Humidity at 38 ° C, 95%
Protection class