YSD KZ55 User Manual Download Page 3

四 Troubleshooting guide

4.1 Introduction

Governor failure is usually caused by mechanical failure

of the installation or position control valve. Before adjusting

the position control valve or controller, carefully check all

electrical connections, power supplies, and valve flexibility.

Manually move the handle on the dial side of the position

control valve manually, from 0 ° to 75 ° without jamming. If a

stagnation occurs at a certain point, it will cause the engine

speed to be unstable when it is near this air supply position.

五 Position control valve parameters

Power supply 20 VDC

32 VDC (24 VDC nominal)

Output torque up to 5Nm
Output current 4A continuous; 10A peak, last 30 seconds
Operating temperature range

40

℃ ~ +

100

Storage temperature range

55

℃ ~ +

125

GJB150.16-1986 Environmental test method for military

equipment (shock test)
Vibration GJB150.16-1986 Environmental test method for

military equipment (vibration test)
Humidity at 38 ° C, 95%
Protection class