Vane alignment is most easily done with two people; one to adjust the 

instrument position and the other to observe the indicating device. 

When anemometer and vane are mounted on the same cross arm 

(Model 03002), the azimuth potentiometer has been aligned at the 

factory such that the mounting cross arm should be oriented North-

South with the vane on the North end.
To install the Wind Sentry, follow these steps:
1.  MOUNT WIND SENTRY

  a)  Connect sensor cable to Wind Sentry junction box.

  b)  Place Wind Sentry on mounting post. Do Not tighten band 

clamp yet.

  c)  Connect sensor cable to indicator.
2.  ALIGN VANE

  a)  Select a known azimuth reference point on the horizon.

  b)  Sighting  down  vane  center  line,  point  counterweight  at 

reference point on horizon.

  c)  While holding vane in position, slowly turn base until indicator 

displays proper value.

  d)  Tighten mounting post band clamp.

CALIBRATION

The  Wind  Sentry  is  fully  calibrated  before  shipment  and  should 

require no adjustments. Recalibration may be necessary after some 

maintenance operations. Periodic calibration checks are desirable 

and may be necessary where the instrument is used in programs 

which require auditing of sensor performance.
For wind direction calibration, the following method can yield an 

accuracy of ±5° or better if carefully done. Begin by connecting 

the  instrument  to  a  signal  conditioning  circuit  which  indicates 

wind  direction  value.  This  may  be  an  indicator  which  displays 

wind  direction  values  in  angular  degrees  or  simply  a  voltmeter 

monitoring the output. Hold or mount the instrument so the vane 

center of rotation is over the center of a sheet of paper which has 

30° or 45° cross markings. Position the instrument so the mounting 

cross arm is oriented north-south with the vane on the north and the 

anemometer on the south. With the counterweight pointing directly 

at the anemometer the azimuth signal should correspond to 180° 

or due south. Looking from above, visually align the vane with each 

of the cross markings and observe the indicator display. It should 

correspond to vane position within 5°. If not, it may be necessary 

to adjust the relative position of the vane skirt and shaft. See step 

3 in the MAINTENANCE section under potentiometer replacement.
It is important to note that while the sensor mechanically rotates 

through  360°,  full  scale  wind  direction  signal  from  the  signal 

conditioning  occurs  at  352°.  The  signal  conditioning  electronics 

must  be  adjusted  accordingly.  For  example,  in  a  circuit  where 

0 to 1 VDC represents 0° to 360°, the output must be adjusted 

for  0.978  VDC  when  the  instrument  is  at  352°  full  scale. 

(352°/360° X 1.000 VDC) = 0.978 VDC)
Wind speed calibration is determined by the cup wheel turning factor 

and  the  output  characteristics  of  the  transducer. The  calibration 

formula  relating  cup  wheel  rpm  to  wind  speed  is  shown  below. 

Standard accuracy is ±0.3 m/s (0.6 mph). For greater accuracy, the 

sensor must be individually calibrated in comparison with a wind 

speed standard. Contact the factory or your supplier to schedule a 

NIST (National Institute of Standards & Technology) traceable wind 

tunnel calibration in our facility.
To calibrate wind system electronics, temporarily remove the cup 

wheel and connect a Model 18802 Anemometer Drive to the cup 

wheel shaft. Apply the calibration formula to the motor rpm and adjust 

the signal conditioning electronics for proper value. For example, 

with the cup wheel shaft turning at 1800 rpm, adjust the indicator to 

display 22.7 meters per second. (0.01250 X 1800 + 0.2 = 22.7 m/s)

CALIBRATION FORMULAS

Model 03002V Wind Sentry Anemometer

 

WIND SPEED  vs 

CUP WHEEL RPM

 

m/s 

(0.01250 x rpm) + 0.2

 

knots 

(0.02427 x rpm) + 0.4

 

mph 

(0.02795 x rpm) + 0.4

 

km/h 

(0.04499 x rpm) + 0.7

 

WIND SPEED  vs 

0-1 VDC OUTPUT

 

m/s 

mV x 0.0500

 

knots 

mV x 0.0972

 

mph 

mV x 0.1118

 

km/h 

mV x 0.1800

 

WIND DIRECTION    vs 

mA OUTPUT

 

  DEGREES  = 

mV x 0.36

MAINTENANCE

Given  proper  care,  the  Wind  Sentry  should  provide  years  of 

service. Because of its durable, corrosion resistant construction, 

the instrument requires little maintenance. The only components 

likely to require replacement due to normal wear are the precision 

ball bearings and the azimuth potentiometer.  Replacement of these 

components should only be performed by a qualified instrument 

technician. If service facilities are not available, return the instrument 

to  the  factory.  Refer  to  the  accompanying  drawings  to  become 

familiar with part names and locations. Maximum torque on all set 

screws is 80 oz-in.

POTENTIOMETER REPLACEMENT

The potentiometer has a life expectancy of fifty million revolutions. 

As it becomes worn, the element may produce noisy signals or 

become non-linear. When the signal noise or non-linearity become 

unacceptable, replace the potentiometer as follows:

1.  REMOVE  POTENTIOMETER

 

a)  Remove  three  screws  which  secure  upper  and  lower 

sections of main housing.

 

b)  Carefully  remove  upper  housing  exposing  wiring 

connections to circuit board.

 

c)  Unsolder  potentiometer  wires  from  circuit  board.   

Note color coding.

 

d)  Using  a  knife  blade  or  similar  instrument,  loosen 

potentiometer assembly from upper housing and slide 

it out.

 

2.  INSTALL  NEW  POTENTIOMETER

 

a)  Slide  new  potentiometer  cell  into  upper  housing.  Be 

sure to engage cell key into housing notch.

 

b)  Solder  potentiometer  wires  to  circuit  board.   

Observe color code.

 

c)  Join two sections of main housing.  Secure with screws 

removed in step 1a.

3.  ALIGN  VANE

 

a)  Connect  excitation  voltage  and  signal  conditioning 

electronics to instrument according to wiring diagram.

 

b)  Loosen set screw in side of vane hub.

 

c)  Position instrument so cross arm is oriented north-south 

with vane on north side. Orient vane to a known angular 

reference. (See CALIBRATION section.)

 

d)  While  holding  vane  in  reference  position,  slowly  turn 

vane    skirt  until  signal  conditioning  system  indicates 

proper value.

 

e)  Tighten  set  screw  on  side  of  vane  hub.  

Do not exceed 80 oz-in torque.