Young 86000-SDI Instructions Download Page 4

86000-SDI-90(G)

Page 3

HEATER ENABLE (aXHn!)   

This enables, disables, or tests the heater control circuit. Disabling 

the heaters removes power from the control circuit. If the Test option 

is used, limited power is continuously sent to each heater zone to 

test heater function at room temperature
SAMPLE COUNT (aXSnnn!)   

This command sets the number of internal samples used to 

calculate the median measurement result. More internal samples 

consume more power while providing greater immunity to conditions 

like turbulent high-speed wind. Fewer samples consume less 

power while providing less immunity to disruptive conditions.  

Default setting is 100.
THRESHOLD (aXTnnn!) 

 

Threshold sets the minimum wind speed needed before a new polar 

wind direction is calculated. The default value is 25 cm/s (0.25 m/s). A 

greater-than-zero threshold can help provide more meaningful scalar 

wind direction averages. The threshold for Cartesian (u-v) output 

format is automatically zero regardless of this setting.
WIND SPEED MULTIPLIER (aXMnnnnn!) 

 

All wind speed measurements are multiplied by this parameter. The 

default value is 10000 for a multiplier of 1.0000.
WIND DIRECTION OFFSET (aXO±nnnn!) 

 

Use this parameter to add or subtract a wind direction offset. Value 

is degrees x 10 and may be positive or negative. Wind direction is 

always re-scaled to a 0-360 range after offset is applied. The default 

value is 00000.

4.4   LOW  POWER OPERATION 

 

With default settings and a 2-second sampling period, the average 

current consumption is less than 4 mA. Average current consumption 

may be reduced further by making fewer measurements (one every 

5 or 10 seconds, for example) or lowering the Sample Count to 

fewer than 16. Lowering the Sample Count below 16 may limit 

measurement accuracy in winds greater than 30 m/s.

4.5   TROUBLESHOOTING 

Symptom: After using setup program, SDI-12 mode is disabled. 

(Note: Setup program is only for RS232 mode.)

Cause: 

Saving parameters in setup program disables SDI-12 

mode.

Solution:  While in RS232 command mode, send the following 

commands via the “Communications” tab in the setup 

software or via a terminal program to re-enable   

SDI-12 mode. (“>” is the command prompt): 

 >SET025 

 

 >SET77 

 

Power cycle the sensor. 

 

Sensor will be in SDI-12 mode.

WIRING DIAGRAM

Use shielded cable.  Connect cable shield to earth ground as shown.

Model 86000-SDI

Ultrasonic Anemometer

5.0  EMC COMPLIANCE

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: (1) this device may not cause harmful 

interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits 

for a Class A digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmful interference when the equipment is operated in a commercial 

environment. This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with 

the instruction manual, may cause harmful interference to radio 

communications.  Operation of this equipment in a residential area 

is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense.
This ISM device complies with Canadian ICES-001.

Cet appareil ISM est conforme à Ia norme NMB-001 du Canada.
EN55011/CISPR 11, Group 1, Class B device.

Class B equipment is suitable for use in domestic establishments and 

in establishments directly connected to a low voltage power supply 

network which supplies buildings used for domestic purposes.

6.0  WARRANTY

This product is warranted to be free of defects in materials and construction 

for a period of 12 months from date of initial purchase. Liability is limited 

to repair or replacement of defective item. A copy of the warranty policy 

may be obtained from R. M. Young Company.

7.0  CE COMPLIANCE

This product has been tested and complies with European  

CE requirements for the EMC Directive.  Please note that shielded 

cable must be used.