Young 85000 Instructions Manual Download Page 9

 Page 6

85000-90

The  default  value  is  4.  When  set  to  00,  no  damping  is  applied. 

Higher damping factors slow the rate at which the sensor indicates 

wind changes.

6.4.10  SET10nnn SET OUTPUT DELAY

Sets the amount of time between measurements in increments of 

8.192 milliseconds. The default value is 122 ( 0.9994 seconds). Lower 

values (less delay) increase power consumption when continuous 

measurements are taken.

6.4.11  SET11nn SET DIRECTION VOUT

Sets wind direction voltage output scale to  0-360 or 0-540 degrees.  

Use the 0-540 scale if possible. When set to 0-360, wind directions 

fluctuating about north cause voltage output swings between zero 

and full scale. Data loggers or display systems may sample during 

these transitions causing erroneous readings. A 0-540 scale elimi-

nates output transitions with northerly wind.

Data in 0-540 form may be re-scaled to 0-360 by subtracting 360 

degrees from any value greater than or equal to 360. The default 

parameter  setting  is  0-360  for  systems  that  cannot  re-scale  the 

0-540 output.

6.4.12  SET12nn SET SAMPLE COUNT

All measurements are calculated from the median of 3 to 31 sample  

sets.  More  samples  consume  more  power.  More  samples  are 

required  at  higher  wind  speeds  or  in  conditions  where  adequate 

samples  are difficult to acquire.  If SAMPLE COUNT is set to 00, 

the sensor automatically uses the minimum number of sample sets 

needed to produce valid data.  However, when powered up for the 

first time or when polling at intervals longer than a few seconds, the 

sensor may require more than one measurement cycle to determine 

the optimum number of sample sets.

In applications where power consumption is not an issue or where 

the sensor must acquire results on the first measurement cycle, the 

SAMPLE COUNT may be set manually to the highest anticipated 

wind speed (m/s) up to 31 which is the maximum SAMPLE COUNT 

value. Wind speeds above 31 m/s will use 31 sample sets.

6.4.13  SET13nn SET ASCII and Vout FORMAT

Serial ASCII and ASCII POLLED formats may be set to provide wind 

data in either Polar (speed and direction) or Cartesian (UV) form. This 

setting also determines the whether voltage outputs are in Polar or 

Cartesian format.

00= Polar, 01=Cartesian (UV).

6.4.14  SET14n SET VOLTAGE OUTPUT STATUS 

Serial ASCII and ASCII POLLED formats report a STATUS CODE 

where non-zero values indicate insufficient samples or measurement 

error. SET14n determines how the STATUS CODE is handled in the 

voltage output.

1 = None (ignore STATUS CODE)

2 = Set Vouts to 0V when STATUS is non-zero

3 = Set Vouts to 5V full scale when STATUS is non-zero

6.4.15 CALnn FORCE VOUT

This command forces both voltage outputs channel to either 0mV 

or 5000 mV. This may be used to calibrate or check the operation of 

external data acquisition devices. 00=0 mV, 01=5000 mV

6.4.16 XX, RPT, and ??

XX 

Returns the sensor to OPERATE MODE.

RPT 

Reports the latest parameter settings.

?? 

Prints a list of commands.

7.0 EXAMPLE SETTINGS

Use the 2DSETUP program for the following suggested settings. Not 

all possible setting combinations are shown. 

 When heaters are enabled the OUTPUT DELAY is forced to 0 and 

SAMPLE COUNT is forced to 31. 

7.1 VOLTAGE OUTPUT ONLY, MINIMUM POWER

 

Serial Output Format: ASCII

 

RS-232 

Disabled

 

RS-485 

Disabled

 

Voltage Output: 

Enabled

 

Output Delay: 

122

 

Sample Count: 

0

7.2 RS-232 ONLY, CONT ASCII OUTPUT, MINIMUM POWER

 

Serial Output Format: ASCII

 

RS-232 

Enabled

 

RS-485 

Disabled

 

Voltage Output: 

Disabled

 

Output Delay: 

122

 

Sample Count: 

0

7.3 RS-232 ONLY, POLLED ASCII OUTPUT, MINIMUM POWER

 

Serial Output Format: ASCII POLLED

 

RS-232 

Enabled

 

RS-485 

Disabled

 

Voltage Output: 

Disabled

 

Sample Count: 

0

7.4 RS-232 ONLY, POLLED ASCII OUTPUT

 

Serial Output Format: ASCII POLLED

 

RS-232 

Enabled

 

RS-485 

Disabled

 

Voltage Output: 

Disabled

 

Sample Count: 

Set to 0 if polling frequently. Set to 

 

 

highest anticipated wind speed (m/s) up 

 

 

to 31 if polling infrequently. Average

 

 

current consumption is a function of

 

 

polling rate and sample count.

7.5 SDI-12 CONTINUOUS

 

Serial Output Format: SDI-12 CONT

 

Output Delay: 

0

 

Sample Count: 

0

7.6 SDI-12 STANDBY

 

Serial Output Format: SDI-12 STANDBY

 

Output Delay: 

0

 

Damping Factor: 

0

 

Sample Count: 

Set to 0 if polling frequently. Set to 

 

 

highest anticipated wind speed (m/s) up 

 

 

to 31 if polling infrequently. Average

 

 

current consumption is a function of

 

 

polling rate and sample count.

Summary of Contents for 85000

Page 1: ...AL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com PN 85000 90 REV J110410 ULTRASONIC ANEMOMETER...

Page 2: ...peration 4 6 0 SETTING SERIAL OUTPUTS AND OPERATING PARAMETERS 6 1 Setup using Young the 2DSETUP program 4 6 2 Setup using terminal Program 4 6 3 Command Overview 4 6 4 Command Details 5 7 0 EXAMPLE S...

Page 3: ......

Page 4: ...data using RS 232 RS 485 or SDI 12 connections Continuous output or polled operation may be used Serial formats may be selected for direct connection to YOUNG Wind Tracker displays marine NMEA systems...

Page 5: ...the mounting post band clamp to secure the position DO NOT OVER TIGHTEN 4 2 4 Slide the orientation ring up so its guide pin is fully engaged in the sensor mounting post notch Tighten the orientation...

Page 6: ...Wind Tracker or other NMEA capable device NMEA FORMAT WIMWV ddd R www w N A cc CR LF where ddd Wind direction degrees www w Wind speed knots Asterisk ASCII 42 cc Checksum CR LF Carriage return line f...

Page 7: ...AM If desired a serial communications program like HyperTerminal may be used Parameters are set using simple commands A limited number of parameters may also be set using SDI 12 commands For serial co...

Page 8: ...tomatically changed as listed below FORMAT ADDITIONAL CODE PARAMETERS CHANGED 01 RMYT BAUD 9600 OUTPUT MODE 07 THRESHOLD 25 cm s OUTPUT DELAY 01 SAMPLE COUNT 31 02 ASCII 03 ASCII POLLED None 04 NMEA B...

Page 9: ...d direction or Cartesian UV form This setting also determines the whether voltage outputs are in Polar or Cartesian format 00 Polar 01 Cartesian UV 6 4 14 SET14n SET VOLTAGE OUTPUT STATUS Serial ASCII...

Page 10: ...oduct has been tested and shown to comply with European CE requirements for the EMC Directive Please note that shielded cable must be used Declaration of Conformity R M Young Company 2801 Aero Park Dr...

Page 11: ...Page 8 85000 90 APPENDIX A WIRING CONNECTIONS...

Page 12: ...Page 9 85000 90 APPENDIX A WIRING CONNECTIONS...

Page 13: ...Page 10 85000 90 APPENDIX A WIRING CONNECTIONS...

Page 14: ...Page 11 85000 90 APPENDIX A WIRING CONNECTIONS...

Page 15: ...Page 12 85000 90 APPENDIX A WIRING CONNECTIONS...

Page 16: ...TION U V U WIND FROM EAST V WIND FROM NORTH EXAMPLE WIND AT 45 OPTIONAL 85052 BIRD WIRE ASSY WHEN PROPERLY ALIGNED JUNCTION BOX FACES SOUTH INSTALL VERTICALLY AS SHOWN TO AVOID MOISTURE DAMAGE TO CIRC...

Reviews: