Young 06201 Instructions Manual Download Page 4

Page 3

06201-90

BRIGHTNESS

Adjust display brightness by holding the BRIGHT key.

MAXIMUM/WIND DIRECTION DIGITAL DISPLAY

The right display window can show either MAXIMUM WIND SPEED 

or Numerical WIND DIRECTION. This selection is made in the setup 

mode under Display (dSP).

REMOTE  DISPLAYS

The  Wind Tracker  can  be  used  as  a  remote  display  by  selecting 

"InP  SEr"  during  SETUP.  Remote  displays  are  connected  to  the 

main display using the RS-485 terminals. Connect like terminals as 

shown in wiring diagrams. Remote displays show exactly the same 

information as the main unit. MAX RESET and SETUP features are 

controlled at the main unit only. Brightness can be adjusted at each 

display independently. Up to 16 remote displays can be connected 

to one main display.  

VOLTAGE OUTPUTS

The  Wind  Tracker  offers  calibrated  voltage  outputs  for  both  wind 

speed and wind direction. This feature allows the use of recorders 

and other devices. Full scale voltage for each channel is 5.00 VDC.

4-20 mA INPUTS

The Wind Tracker accepts 4-20 mA (Line Driver) inputs. The Line 

Driver circuit must provide 0 - 50 M/S Wind Speed scaling ("M" suffix). 

Connect cable as indicated on page 4. Switch on back must be UP at 

power up for correct 4-20 mA operation. Set INPUT to "LDI" in SETUP. 

Note: 24 VDC power is required for line driver applications.

ERROR  MESSAGES

The Wind Tracker detects and indicates two errors. Once corrected, 

the error indication disappears.

DISPLAY 

 

LDi 

Err

 

4-20 mA (line driver) signal is missing or out-

side of acceptable range. Verify proper switch 

position or signal.

SEr 

Err

 

Unit is set to receive RS-485 serial signal, (inP 

SEr) but no serial data is coming in. Verify  

that the serial source is operating. Check 

cables for proper connection.

WARRANTY

The Wind Tracker is warranted to be free of defects in materials and 

construction for a period of 12 months from date of purchase. Cover-

age is limited to repair or replacement of defective unit.

SPECIFICATIONS

Size:  144 mm (5.65 in) x 144 mm (5.65 in) x  

 

 

 

 

36 mm (1.4 in)

Panel Cutout:  138 mm (5.43 in) x 138 mm (5.43 in)

Compatible Sensors: 

 

 

Wind Monitor

 

 

Wind Monitor-SE

 

 

Wind Monitor-MA

 

 

Wind Monitor-AQ

 

 

Wind Monitor-JR 

 

 

Wind Sentry

Other Inputs:  RS-485, 4-20 mA

Accuracy:   

±0.6% F.S.

Display Resolution:

 

 

Wind Direction: 

10° circular pattern (36 points)

 

 

 

 

 

 

1° digital w/ 

dSP dIr 

selected

 

 

Wind Speed & 

 

 

       Maximum: 

1 Knot, 1 MPH, 1 KM/H, 0.1 M/S

Voltage Outputs:

 

 

Wind Direction Range:

 

 

 

0-5 VDC   

 0-360°

 

 

Wind Speed Range:  (dependent on units selected) 

 

 

 

0-5 VDC   

0-100 Knots

 

 

 

   

 

0-100 MPH

 

 

 

   

 

0-200 KM/H

 

 

 

   

 

0-50  M/S

Alarm Relays:   Non-latching 

 

 

Normally Open contacts for WS and WD.    

 

 

 

Contact rating 5A resistive, 

 

 

2A inductive @ 24 VAC, 30 VDC.

Input Power:  12-30 VDC, 4.5 W

Weight:  1.0 lb (0.45 kg) without AC adapter

CE COMPLIANCE

This product has been tested and shown to comply with European CE 

requirements for the EMC Directive. Please note that shielded cable 

must be used.

Declaration of Conformity

R. M. Young Company

2801 Aero Park Drive

Traverse City, MI 49686 USA

Model  06201 WIND TRACKER

The undersigned hereby declares on behalf of R. M.

Young Company that the above-referenced product, to

which this declaration relates, is in conformity with the

provisions of:

Council Directive 2004/108/EC (December 15, 2004)

on Electromagnetic Compatibility

David Poinsett

R&D Manager

Reviews: