Page 3
06201-90
BRIGHTNESS
Adjust display brightness by holding the BRIGHT key.
MAXIMUM/WIND DIRECTION DIGITAL DISPLAY
The right display window can show either MAXIMUM WIND SPEED
or Numerical WIND DIRECTION. This selection is made in the setup
mode under Display (dSP).
REMOTE DISPLAYS
The Wind Tracker can be used as a remote display by selecting
"InP SEr" during SETUP. Remote displays are connected to the
main display using the RS-485 terminals. Connect like terminals as
shown in wiring diagrams. Remote displays show exactly the same
information as the main unit. MAX RESET and SETUP features are
controlled at the main unit only. Brightness can be adjusted at each
display independently. Up to 16 remote displays can be connected
to one main display.
VOLTAGE OUTPUTS
The Wind Tracker offers calibrated voltage outputs for both wind
speed and wind direction. This feature allows the use of recorders
and other devices. Full scale voltage for each channel is 5.00 VDC.
4-20 mA INPUTS
The Wind Tracker accepts 4-20 mA (Line Driver) inputs. The Line
Driver circuit must provide 0 - 50 M/S Wind Speed scaling ("M" suffix).
Connect cable as indicated on page 4. Switch on back must be UP at
power up for correct 4-20 mA operation. Set INPUT to "LDI" in SETUP.
Note: 24 VDC power is required for line driver applications.
ERROR MESSAGES
The Wind Tracker detects and indicates two errors. Once corrected,
the error indication disappears.
DISPLAY
LDi
Err
4-20 mA (line driver) signal is missing or out-
side of acceptable range. Verify proper switch
position or signal.
SEr
Err
Unit is set to receive RS-485 serial signal, (inP
SEr) but no serial data is coming in. Verify
that the serial source is operating. Check
cables for proper connection.
WARRANTY
The Wind Tracker is warranted to be free of defects in materials and
construction for a period of 12 months from date of purchase. Cover-
age is limited to repair or replacement of defective unit.
SPECIFICATIONS
Size: 144 mm (5.65 in) x 144 mm (5.65 in) x
36 mm (1.4 in)
Panel Cutout: 138 mm (5.43 in) x 138 mm (5.43 in)
Compatible Sensors:
Wind Monitor
Wind Monitor-SE
Wind Monitor-MA
Wind Monitor-AQ
Wind Monitor-JR
Wind Sentry
Other Inputs: RS-485, 4-20 mA
Accuracy:
±0.6% F.S.
Display Resolution:
Wind Direction:
10° circular pattern (36 points)
1° digital w/
dSP dIr
selected
Wind Speed &
Maximum:
1 Knot, 1 MPH, 1 KM/H, 0.1 M/S
Voltage Outputs:
Wind Direction Range:
0-5 VDC
0-360°
Wind Speed Range: (dependent on units selected)
0-5 VDC
0-100 Knots
0-100 MPH
0-200 KM/H
0-50 M/S
Alarm Relays: Non-latching
Normally Open contacts for WS and WD.
Contact rating 5A resistive,
2A inductive @ 24 VAC, 30 VDC.
Input Power: 12-30 VDC, 4.5 W
Weight: 1.0 lb (0.45 kg) without AC adapter
CE COMPLIANCE
This product has been tested and shown to comply with European CE
requirements for the EMC Directive. Please note that shielded cable
must be used.
Declaration of Conformity
R. M. Young Company
2801 Aero Park Drive
Traverse City, MI 49686 USA
Model 06201 WIND TRACKER
The undersigned hereby declares on behalf of R. M.
Young Company that the above-referenced product, to
which this declaration relates, is in conformity with the
provisions of:
Council Directive 2004/108/EC (December 15, 2004)
on Electromagnetic Compatibility
David Poinsett