SAY HELLO TO YOUR RED LIGHT

660nm of red light.

This light can be seen by the eyes and targets skin cells.

850nm of near infrared light.

This light cannot  be seen by the eyes and targets deep tissue.

-1-

THIS PACKAGE INCLUDES

1* Red light device

1* Power cable

1* eye protection

1* door hook

2* rope clip hanger

1* User manual

TIME CONTROLLER EXPLANATION

Thank you for purchasing our red light therapy, we hope you can get benefits from our device .

Before starting your first session, please make sure to read this manual as it may explain important operating

procedures. The red light devices use red 660nm and Infrared 850nm leds which is chosen to give the ideal

wavelengths found in the scientific research of the last three decades .

SPECIFICATION

Product Name

>110 mW/cm² @6inch

265*220*70mm
10.43"x8.66"x2.76"

Power

Actual Power

Input Voltage

LED QTY

Bean Angle

Irradiance

Spectrum

Material

Dimensions(mm)

Lifespan

Net Weight (kg)

YL-IRP-001

500W

150W

AC110-240V

100pcs 3W(default) / 5W

30° or customized

850:660 1:1 or customize

lron

50,000

2.50kg

>120 mW/cm² @6inch

480*220*70mm
18.90"x8.66"x2.76"

YL-IRP-002

1000W

300W

AC110-240V

200pcs 3W(default) / 5W

30° or customized

850:660 1:1 or customize

lron

50,000

5.10kg

-2-

Increase Button

Set Button

Decrease Button

PV time1

SV time2

Restart Button

RED-LIGHT-THERAPY FOR HUMAN

>130 mW/cm² @6inch

690*220*70mm
27.17"x8.66"x2.76"

YL-IRP-003

1500W

450W

AC110-240V

300pcs 3W(default) / 5W

30° or customized

850:660 1:1 or customize

lron

50,000

6.90kg

>135 mW/cm² @6inch

920*220*70mm
36.22"x8.66"x2.76"

YL-IRP-004

2000W

600W

AC110-240V

400pcs 3W(default) / 5W

30° or customized

850:660 1:1 or customize

lron

50,000

8.90kg

OPERATION GUIDE

1. Turn on the power switch, the time controller is on. Long press the "set" button, the       is "P0",

and press the increase/decrease button to select the type of timing unit: 0,1,2; Our products

is "1",that means the timing unit  is minute.

PV

SV

Code

Item

Vlue

Introduction

Remark

P0

Timing unit

0

1

2

Second

Minute

Hour

Time range: 0-999s

Time range: 0-999min

Time range: 0-999h

The PV setting is "P0"

SV setting is timing unit

0 means the timing unit is second

1 means the timing unit is minute

0 means the timing unit is hour

Our products  the timing unit  is minute, so PV is "P0" / "SV" is "1"

After P0 is set, wait for 3 seconds. The device automatically saves the Settings and rolls back display.

2. After setting the timing unit, long press the set button, the PV is "P0", then press the set again,

the PV change to "P1", and press the increase / decrease button to select the type of operating
mode: 0,1,2,3,4,5; Our products SV is "2", that means timed off after timing on.

The PV setting is "P1"

SV setting is "2"