Yoshitake TA-2 Instruction Manual Download Page 4

 

EPDT-198

 

5. Operation 

 

(1) Before water flowing, the float [7] is in low position and the floating valve [2] is opened.

Fig. 4-1

 

(2) When water starts to flow into the valve, air inside piping is pushed by water and exhausted out through 

quick exhaust hole.

Fig. 4-2

 

(3) The float [7] is pushed up by water flowing into the product, and the valve [3] connected with the float is 

closed.

Fig. 4-3

 

(4) When air flows into the product, the float [7] is lowered immediately, and at the same time the valve [3] is 

lowered, and therefore air is exhausted out through quick air vent hole.

Fig. 4-4

 

 

    ■

Operation 

 

 

 
 
 
 
 
 
 
 
 

 

 
 
 

 

                                                                   

 

 
 
 
 
 
 
 
 
 
 
 

    ■

Structure 

No. 

Parts name 

Valve seat 

Floating valve 

Valve 

Valve guide 

Hanger 

Cover 

Float 

Body 

 
 
 
 
 
 

 
 
 

Air bubble 

Air 

Fig. 4-2

 

Fig. 4-1

 

Fig. 4-3

 

Fig. 4-4

 

Air 

Before water flowing

 

During water flowing

 

Water flowing is completed

 

Air 

commingling

 

Normal  exhaust  hole 

Quick  exhaust  hole 