background image

■ EP D T-048■  

3. Operation

 

 
 
 

No. 

Parts Name 

Body 

Cap (15A-50A) 

Cover (65A-150A) 

Screen 

Gasket 

Plug 

 
 
 
 

Dust, scale, and other foreign substances which flow into the inlet side of the strainer are removed by 
the screen [3]. 

 

4. Nominal Size Selection

 

To make the best use of the strainer and satisfy the operating requirements to the maximum, 
take notice of the following. 

 

4.1 Selection of nominal size 

Select a strainer of the same nominal size as that of the pipe (nominal size of piping = nominal size 
of strainer). Note that using a strainer of a smaller nominal size increases the pressure loss of the 
strainer and may result in the pressure fallen below the specified level at the inlet side of the 
equipment. 

 
4.2 Selection of nominal pipe size 

When selecting an appropriate nominal pipe size, it is necessary to consider fluid type, maximum 
flow rate, permissible pressure loss, costs of piping and equipment, etc. 
If the nominal pipe size is smaller, the costs of piping and equipment decreases while the pressure 
loss through the pipe increases to generate disturbances, possibly resulting in pipe wear, noise 
and/or vibration. If the nominal pipe size is too large, not only the costs of piping and equipment but 
also the thermal loss increases. 
As a reference, the standard flow velocity is specified in the Japanese Industrial Standards (JIS) as 
a guide to select an appropriate nominal pipe size. See the following table. 

 

<<Standard flow velocity>> 

Fluid 

Remarks 

Standard flow 

velocity 

Saturated steam 

Auxiliary piping for vacuum or small-
diameter piping 

15 m/s [10-20] 

Large-diameter piping 

30 m/s [20-40] 

Superheated steam 

Piping diameter: approx. 

Φ

75 –

Φ

250 

40 m/s [30-50] 

Piping of high-grade material 

70 m/s [65-80] 

Inlet of steam coil 

0.3-0.7 MPa 

30 m/s [25-30] 

Air 

Higher pressure: 1.0 MPa or more 

20 m/s [20-25] 

Lower pressure 

15 m/s [5-15] 

Extremely low pressure: 0.1 MPa or less 

10 m/s [3-10] 

Water, Oil 

             

2 m/s [2- 4] 

* The above table is based on the requirements in JIS F 7101 “Shipbuilding - Pipes 

of machinery - standard velocity of flow”. 

 

15A - 50A 

65A - 150A 

Summary of Contents for SY-8

Page 1: ...t in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents 1 Sp...

Page 2: ...FF flanged If the temperature is over 150 C another material is used for the gasket Please contact us Available with JIS 20K Flanged Up to 50A Available with 20 to 100 mesh screens 2 Dimensions mm No...

Page 3: ...nominal pipe size is smaller the costs of piping and equipment decreases while the pressure loss through the pipe increases to generate disturbances possibly resulting in pipe wear noise and or vibra...

Page 4: ...3 EPD T 048 4 3 Pressure Loss Chart Screen 15A to 100A 2 5 7 21 holes cm2 Mesh 80 mesh 125A to 150A 6 2 05 holes cm2 Mesh 80 mesh Nominal size P Pressure loss MPa V Flow rate L min...

Page 5: ...shall be installed with its cap or cover faced downward If drainage or similar problem occurs in a steam line incline the product to the position at which the cap or cover is kept horizontally 3 If t...

Page 6: ...ssure gauge to make certain there is no pressure inside the body 1 remove the cap or cover 2 and screen 3 Clean up the screen 3 by compressed air or water 6 2 Precaution for reassembly Caution 1 Clean...

Page 7: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...

Reviews: