background image

     -7-                     

EPDT-147b

 

8.Maintenance Procedure 

8.1

 Troubleshooting 

Trouble condition

 

Cause of trouble 

Countermeasure and 

remedy 

No fluid flows. 

1.

Screen

  is clogged up. 

 

2.

Stop valves at inlet and/or 

outlet side are shut. 

1.

Disassemble and 

clean the screen

2.

Open stops valves. 

Pressure loss is 
excessive. 

1.

Screen

  is clogged up. 

 

2.

Pressure gauge is damaged. 

1.

Disassemble and 

clean the screen

2.

Renew the Pressure 

gauge 

Outer leakage 
accure 

1.

Gasket have deterioration. 

1.

Replace the gasket. 

 

8.2

 Precautions during maintenance and inspection 

 

Warning 

(1)

 

Completely discharge internal pressure from the strainer, lines, and equipment, 

and cool the strainer down to a level where you can touch it with bare hands 
before disassembly and inspection. 

Failure to do so may result in injury or burns due to residual pressure or 

spillage around the product. 

(2)

 

In case the high temperature of fluid is applied, keep the bare hand off the 

strainer. 

It may cause the personnel being scalded. 

(3)

 

Since the screen is heavy in weight, when extracting the screen from the body, 

make sure to secure it properly with lifting devices. 

The screen fallen down may cause the injury. 

 

8.3

 Disassembly Procedure 

(1)After confirming that the remaining pressure is relieved from the strainer, remove 

the bolts

  from the cover

and the gasket

, and remove the cover

  from 

the body

. Extract the screen

  from the body

  and clean it with compressed 

air or cleanser. 

 
 
 
 
 
 

 

Summary of Contents for SY-20-10

Page 1: ...ly injury Caution Indicates that mishandling this product might cause bodily injury or material damage Table of Contents 1 Overview 1 2 Specifications 1 3 Dimensions and Weights 1 4 Operation 2 5 Pres...

Page 2: ...minal Size Application Steam Cold and hot w Oil Other non dangerous fluids Maximum Pressure MPa MPa Maximum Temperature Material Body Screen Screen Perforated plate holes Element mesh Mesh Screen are...

Page 3: ...3 4 18 3 100A 362 280 114 187 0 100 R 3 4 34 2 125A 420 330 140 224 5 125 R 3 4 46 3 150A 520 386 184 308 5 150 R 3 4 75 1 mm Size Screen Plug Weight kg 15A 160 104 25 56 5 15 R 3 8 3 2 20A 160 113 30...

Page 4: ...tallation cost among others Smaller diameter of pipe makes the lower piping cost but the pressure loss will be increased and there are possibilities of abrasion of pipe noise and vibration due to turb...

Page 5: ...4 EPDT 147b 5 3 Pressure loss diagram Fluid Water Screen Perforated plate 6 0 1 80holes cm2 Element 80mesh...

Page 6: ...nd inspection cleaning of the screen 4 Do not apply excessive load torque or vibration to the valve The fluid may leak from strainer 5 Carry out the connection with pipes properly Improper piping conn...

Page 7: ...ill be a danger of personnel being scalded The fluid flowed out of pipe end may cause some material damages Do not tighten the cap and the cover after flowing the fluids to the valve The gasket will b...

Page 8: ...ent and cool the strainer down to a level where you can touch it with bare hands before disassembly and inspection Failure to do so may result in injury or burns due to residual pressure or spillage a...

Page 9: ...akage may cause being scalded 1 When tighten the nut Please confirm That apicalpart of stud bolt will Come out from flange and nut 8 5 Assembly Clean the gasket contacting surface of the body and cap...

Page 10: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...

Reviews: