Yoshitake PG-2 Product Manual Download Page 4

 

EPDT-299a

 

 

 

          Caution 

1.  Install the product so that scale plate is vertical. 

* If not vertical, accidental error can be made. 

2.    In  case  of  liquid  measurement,  if  there  is  head  difference  between  pressure  pick-up  port  and 

pressure  gauge,  accuracy  is  influenced.  For  example,  to  measure  water  pressure,  if  installing 
pressure  gauge  of  pressure  range  0  to  0.1  MPa  on  the  place  of  1  m  higher  than  pressure  pick-up 
port, reading is the value of actual pressure minus 0.01 MPa. This difference is equivalent to 10% of 
all scale range (Fig. 4). Conversely, if installing pressure gauge of pressure range 0 to 0.1 MPa on 
the place of 1 m lower than pressure pick-up port, reading is the value of actual pressure plus 10% 
(Fig. 5). 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
           

 

 
3.    Avoid using the product at place where it is exposed to high temperature. If necessary, prevent the 

product from being exposed to heat directly by using closure plate, etc. 

4.    If the fluid temperature to measure exceeds the max. temperature, mount a siphon tube to the product 

to reduce the fluid temperature. Be sure to inject water to the siphon tube to protect the product.

 

5.    Avoid using the product at place where much vibration occurs. 
6.    If fluid has pulsation, use dampener to install the product. To adjust dampener, close it fully at once, 

then adjust it by opening little by little. In this case, do not tighten the product enough to stop pointer 
swinging completely. Adjust to the extent that pointer swing remains slightly. 

7.    To  install  the  product,  be  sure  to  apply  appropriate  tool  such  as  spanner  to  hexagonal  part  and 

tighten it. Be sure to avoid screwing the product with holding the product case. 

8.    Before  installing  the  product,  be  sure  to  remove  foreign  substances  and  scale  from  the  piping. 

During  installation,  prevent  foreign  substances  flowing  into  the  piping,  such  as  packing,  seal  tape, 
liquid seal agent, etc. 
* Commingling of foreign substance or scale into the product prevents the product from functioning 
properly.   

 
 

Fig. 4 

Fig. 5 

Main pipe 

Main pipe 

H

e

a

d

 d

if

fe

re

n

c

e

 

H

e

a

d

 

d

if

fe

re

n

c

e

 

Pock-up port 

Pick-up port 