4. Installation and operation 

4.1 Precautions for installation 

 Caution 

(1) The noiseless heater should be mounted 300mm or more from the tank’s walls and 

bottom. (Refer to 4.2 Example of piping) 

*

 

Vibration may occur in a tank by the flow of a liquid. 

(2) Use it within the maximum warning sound temperature limit. 

*

 

Vibration in a tank and piping occurs. 

(1) In order to obtain a result as planned, please fully utilize the nominal size selection 

chart. 

(2) There are various methods in attachment and please take into consideration the 

blow-off position with the size of a tank etc. (Refer to 4.2 Example of piping) 

(3) Submerge the product in the tank. If it is unavoidable, keep it as close to the water 

surface as possible. (Refer to 4.2 Example of piping) 

When using the method shown in Fig. 3, make the L dimension as short as 
possible. 

(4) VB-7 vacuum relief valve is recommended in the piping in order to prevent a back-

flow condition when the steam is stopped. 

 

4.2 Example of piping 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig.1 

Fig.2 