![Yoshitake CF-90 Product Manual Download Page 5](http://html1.mh-extra.com/html/yoshitake/cf-90/cf-90_product-manual_3542896005.webp)
‐
5
‐
■
EPDT
-
337a
■
4. Precautions for installation
Caution
(1) Before installing the product, remove foreign substances and scale from the piping,
and note that seal materials must not flow into the inside of the product or piping.
Commingling of foreign substances such as scale or seal material leads to
malfunction of the product.
(2) The product can be installed either horizontally or vertically.
To install the product, check the direction on the label of the product so that the
fluid flowing and the mark on the product are in the same direction.
*
Wrong direction leads to malfunction of the product.
(3) Install pipes so that excessive load, torque or vibration is not applied to the
product.
(4) If component having negative effect on inner parts is included in fluid and
environment, deterioration of rubber parts is accelerated and causes outside
leakage and functional disorder.
(5) Impact by rapid pressure change, such as water hammer, breaks the product or
parts.
(6) If fluid cannot flow due to closed piping situation of the product, fluid temperature
rise expands volume of fluid in the piping and damages the product.
(7) Secure enough space needed for maintenance and inspection of the product.
(8) Do not make dissimilar metal piping which causes difference of electrical potential.
If doing so, the product and parts are corroded.
(9) Consider usage condition (usage frequency or durability) when selection.
(10) Install a strainer (mesh size of 60 or 80) at the inlet side of the product.
* Commingling of foreign substances such as scale material leads to prevent the
product from functioning properly.
(11)
The majority of product failures are happened due to scales such as sands and
dust in the pipeline. Please pay attention to the dust inside the pipeline.
(12)
Be sure to install bypass piping.
*The noise level is greatly affected by the condition of the piping system and indoor
environment. To balance the total flow rate, use a bypass pipe to reduce the flow
velocity or make other adjustments.
(13) The products cannot be used with pipe end core.
Fig.4 Piping example
Stop valve
Stop valve
Stop valve
Bypass
CF-90
Constant Flow Valve
Strainer
Stop valve