7. Maintenance 

 

          Warning 

1.  Do not touch the product/pipes with bare hands when touching them or operating the lever or operating 

with lever [14].   
* Failure to follow this notice may result in scalds or injury. 

2.  Do not touch the product unless it is necessary. 

* Failure to follow this notice may result in scalds or injury when fluid is high temperature. 

3.  When checking the operation of the product, wear earplugs and stand clear of exhaust pipe end during 

inspection. Do not look down or touch the open end of the exhaust pipe. 
* Failure to follow this notice may result in injury due to discharge. Be aware that the product makes a 
loud noise at start-up. 

4.  Do not disassemble the product. 

* Please contact us if any abnormal condition is observed. 

 

          Caution 

1.  Before raising fluid pressure, check that no problems have occurred in the equipment on the piping. 

* Failure to follow this notice may damage the equipment. 

2.  Completely discharge fluid from the product and piping before leaving the product not operated for a long 

time. 
* Failure to follow this notice may cause malfunction due to rust generation in the product or piping. 

3.    After leaving the product not operated for a long time, make inspection before start-up. 

Summary of Contents for AL-6

Page 1: ...ates a potentially hazardous situation that if not avoided could result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or modera...

Page 2: ...e seat leakage The product has allowable valve seat leakage and does not close completely valve seat leakage cannot be zero 2 Do not use the product for equipment or device which vibrates excessively...

Page 3: ...sions mm Weight kg d L H1 H 65A 331 9 65 120 120 479 20 2 80A 441 8 75 130 130 132 493 495 24 0 100A 785 4 100 160 150 152 626 628 44 0 125A 1227 2 125 200 205 207 835 837 88 0 150A 1767 2 150 210 215...

Page 4: ...e of the safety relief valve decreases when the fluid is released into the atmosphere by the pop action of the valve 5 the force of fluid lift is lowered At this point the repelling force of the sprin...

Page 5: ...Pa 1 1 1 2 1 3 1 4 1 5 65A 1976 2138 2299 2461 2621 80A 2631 2846 3060 3276 3489 100A 4677 5059 5440 5825 6203 125A 7309 7906 8500 9102 9692 150A Boiler structure standards kg h Nominal size Set press...

Page 6: ...ngs if the product is installed on a place where there is a risk that fluid blowout causes alarm activation or contamination of the peripheral equipment Improper placement may cause contamination of t...

Page 7: ...h the open end of the exhaust pipe Failure to follow this notice may result in injury due to discharge Be aware that the product makes a loud noise at start up 4 Do not disassemble the product Please...

Page 8: ...please contact us for repair at our factory 2 Damage on contact surface between valve 5 and valve seat 4 2 The product needs to be disassembled and its parts need to be replaced Please contact us for...

Page 9: ...nd cleaned Please contact us 4 There is a back pressure at the piping of the product outlet 4 Remove the back pressure In addition change the piping layout not to allow back pressure 5 The product doe...

Page 10: ...pair at our factory After lever operation the product does not stop blowing even if letting go of the lever 1 Scale stuck on contact surface between valve 5 and valve seat 4 1 Remove the scale by oper...