background image

 2

5. SA218S Level Control

This control adjusts the volume level of the SA218S relative to the input signal level. Mixers and other audio 

sources connected to the SA218S tend to have different output voltages, which mean the level control on the 

SA218S is used to fine tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set 

the SA218S Level above or below the center 0 dB setting.

6. Clip, X-Max, VC-Therm, Activity Indicators

The Clip and Limit LED indicators illuminate to guide the user to proper operating levels.

Illumination either of the yellow Limit LEDs indicates that a level has been reached where the SA218S limit-

ers are reducing the signal internally to prevent damage or distortion. It also indicates that further increases in 

input level or increasing the SA218S Level control position will not appreciably increase acoustic output. 

The red Clip LED indicates that the input level is excessive and further increases in level will cause severe 

distortion The input signal should be reduced at the source until Clip activity ceases. The clip indicator comes 

on at 12 Vrms,16 volts peak. The input clips at 17 Vrms, 24 volts peak.

The activity Indicator comes on at 5 mVrms or -45 dBV.

7. Line Current Limit Control

The Line Current Limit control allows the power to be reduced to allow operation on limited power availability. 

Full power transients will be allowed through but if the average power is excessive then the power will be lim-

ited. This control works by advancing the limiter that limits the voice coil temperature and by monitoring the cur-

rent draw. In the 10 amp (5 amp CE) position the average power is limited only by the voice coil temperature. 

In the 8 amp (4 amp CE) position with most music, the limiter will be only active occasionally depending on the 

music content. In the 7 amp (3.5 amp CE) position certain types of music will not be limited, primarily music 

without deep bass or where the bass is unprocessed. The 5 amp (2.5 amp CE) position will significantly reduce 

the output when the music content has continuous bass content below 45 Hz. The green power on indicator will 

dim to indicate when the line current limiter is active. A small amount of dimming indicates that the advanced 

thermal limiter is active while significant dimming indicates that the line current monitoring system has detected 

excessive line current. Low line voltage typically due to long power supply cables may cause excessive line 

current, the line current monitoring system will prevent this from tripping the power source circuit breakers.

Summary of Contents for synergy SA218S

Page 1: ...OWNER S MANUAL MANUEL DE L UTILISATEUR SA218S SA218S...

Page 2: ...nt de la chaleur Les dispositifs marqu s d une symbole d clair sont des parties dangereuses au toucher et que les c blages ext rieurs connect s ces dispositifs de connection ext rieure doivent tre eff...

Page 3: ...ned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if...

Page 4: ...the Average Power limiter is advanced With many types of music the effect of the VC therm limiter will be minimal 1 Power Switch and Indicator The green power LED illuminates when the power switch is...

Page 5: ...dicator comes on at 5 mVrms or 45 dBV 7 Line Current Limit Control The Line Current Limit control allows the power to be reduced to allow operation on limited power availability Full power transients...

Page 6: ...surveillant attentivement ces voyants de limiteur lorsque la commande est modifi e pendant le fonctionnement en limite Le voyant VC therm s allume plus t t lorsque le limiteur de Puissance Moyenne es...

Page 7: ...doit tre r duit la source jusqu ce que l activit d cr tage cesse La DEL CLIP s allume 12 Vrms 16 volts cr te L entr e s cr te 17 Vrms 24 volts cr te L indicateur d activit s allume 5 mVrms ou 45 dBV 7...

Page 8: ...passif Actif Puissance du programme watts 6000 watts Programme 12000 watts cr te NPA maximum mesur pond r C maintien maximum 130dB Cont 142 dB cr te R ponse en fr quence Hz 3dB 30 Hz 100 Hz Fr quence...

Page 9: ...6...

Page 10: ...uivalent heavy duty cord supplied by the manufacturer 4 The AC supply cord should be routed so that it is unlikely that it will be damaged Protect the power cord from being walked on or pinched If the...

Page 11: ...alent usage intensif fourni par le fabricant 4 Le cordon d alimentation CA doit tre achemin de mani re qu il soit peu probable qu il soit endommag Prot gez le cordon d alimentation pour qu il ne soit...

Page 12: ...C T U R E D B Y Y O R K V I L L E S O U N D block diagram SYNERGY SA218S 00 1v0PR01 Output Input XLR Sub Level 50Hz LP AC Line Current Sense Line Current Limit Microcontroller DSP ADC DAC 2 3 1 2 3 1...

Page 13: ...pr s de Yorkville Sound ou de votre d taillant Si pour une raison quelconque ce produit devient d fectueux durant les deux ann es qui suivent la date d achat initial dix ans pour l b nisterie retourne...

Page 14: ...alls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 839 5776 REA...

Reviews: