YORKVILLE LP-C12 Service Manual Download Page 2

The exclamation point within an equilatereal triangle is intended to alert the 
user to the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the appliance.

Le point d’exclamation à l’intérieur d’un triangle équilatéral est prévu pour alerter 

l’utilisateur de la présence d’instructions importantes dans la littérature accompagnant 

l’appareil en ce qui concerne l’opération et la maintenance de cet appareil. 

This lightning flash with arrowhead symbol, within 
an equilateral triangle, is intended to alert the user to the presence of 
uninsulated “dangerous voltage” within the product’s enclosure that may be 
of sufficient magnitude to constitute a risk of electric shock to persons.

Ce symbole d’éclair avec tête de flèche dans un triangle équilatéral est prévu pour alerter 
l’utilisateur de la présence d’un « voltage dangereux » non-isolé à proximité de l’enceinte 
du produit qui pourrait être d’ampleur suffisante pour présenter un risque de choque 

_safety-5v0+UL60065-00-1v0 • October 28/2014

CAUTION

: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

THIS DEVICE IS FOR INDOOR USE ONLY!

Instructions pertaining to a risk of fire, electric shock, or injury to a person

Read Instructions: 

The Owner’s Manual should be read and understood before operation of your unit. Please, save these 

instructions for future reference and heed all warnings. 
Clean only with dry cloth.
Packaging: Keep the box and packaging materials, in case the unit needs to be returned for service.
Warning: To reduce the risk or fire or electric shock, do not expose this apparatus to rain or moisture. 

Do not 

use this apparatus near water!

Warning: When using electric products, basic precautions should always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage specified in the owners manual or as marked on the 
unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted. 

Precautions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I 
construction shall be connected to a Mains socket outlet with a protective earthing ground. Where the MAINS plug or an 

appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal 
injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the 
manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting 

accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer
Note: Prolonged use of headphones at a high volume may cause health damage on your ears. 

The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be 

placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals require 

installation by an instructed person or the use of ready made leads or cords.

Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

No naked flame sources, such as lighted candles, should be placed on the apparatus.

Power Cord

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 
other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. The AC supply 
cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched particularly 
at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC 
Mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily 

operable.

Unplug this apparatus during lightning storms or when unused for long periods of time.

Service

The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has been damaged in 

any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

AVIS: 

AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE, N’ENLEVEZ PAS LE COUVERT

(OU LE PANNEAU ARRIERE) 

NE CONTIENT AUCUNE PIECE REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE POUR L’ENTRETIENT

CE PRODUIT EST POUR L’USAGE À L’INTÉREUR SEULEMENT

Instructions relatives au risque de feu, choc électrique, ou blessures aux personnes

Veuillez Lire le Manuel: 

Il contient des informations qui devraient êtres comprises avant l’opération de votre appareil. 

Conservez. Gardez S.V.P. ces instructions pour consultations ultérieures et observez tous les avertissements.   
Nettoyez seulement avec le tissu sec.

Emballage: Conservez la boite au cas ou l’appareil devait être retourner pour réparation.
Avertissement: 

Pour réduire le risque de feu ou la décharge électrique, n'exposez pas cet appareil à la pluie ou à l'humidité. 

N’utilisez pas cet appareil près de l’eau!

Attention: Lors de l’utilisation de produits électrique, assurez-vous d’adhérer à des précautions de bases incluant celle qui suivent:

Alimentation

L’appareil ne doit être branché qu’à une source d’alimentation correspondant au voltage spécifié dans le manuel ou tel 

qu’indiqué sur l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. Ne pas utiliser cet appareil avec un 

cordon de raccordement à moins qu’il soit possible d’insérer complètement les trois lames. Des précautions doivent êtres 
prises afin d’eviter que le système de mise à la terre de l’appareil ne soit désengagé.  Un appareil construit selon les normes 

de CLASS I devrait être raccordé à une prise murale d’alimentation avec connexion intacte de mise à la masse. Lorsqu’une 
prise de branchement ou un coupleur d'appareils est utilisée comme dispositif de débranchement, ce dispositif de 

débranchement devra demeurer pleinement  fonctionnel avec raccordement à la masse.

Risque

Ne pas placer cet appareil sur un chariot, un support, un trépied ou une table instables. L’appareil pourrait tomber et blesser 

quelqu’un ou subir des dommages importants. Utiliser seulement un chariot, un support, un trépied ou une table 

recommandés par le fabricant ou vendus avec le produit. Suivre les instructions du fabricant pour installer l’appareil et utiliser 

les accessoires recommandés par le fabricant. 

Utilisez seulement les attachements/accessoires indiqués par le fabricant

Note: L'utilisation prolongée des écouteurs à un volume élevé peut avoir des conséquences néfastes sur la santé 

sur vos oreilles. . 

Il convient de ne pas placer sur l’appareil de sources de flammes nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des éclaboussures et qu’aucun objet rempli de liquide tel 

que des vases ne doit être placé sur l’appareil.

Assurez que lappareil est fourni de la propre ventilation. Ne procédez pas à l’installation près de source de chaleur tels 

que radiateurs, registre de chaleur, fours ou autres appareils (incluant les amplificateurs) qui produisent de la chaleur.

Les dispositifs marqués d’une symbole “d’éclair” sont des parties dangereuses au toucher et que les câblages 

extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en 
utilisant des cordons déjà préparés.

Cordon d’Alimentation

Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige de mise à la masse du cordon d’alimentation. 

Une prise polarisée dispose de deux lames dont une plus large que l’autre. Une prise avec tige de mise à la masse dispose de 
deux lames en plus d’une troisième tige qui connecte à la masse. La lame plus large ou la tige de mise à la masse est prévu 
pour votre sécurité. La prise murale est désuète si elle n’est pas conçue pour accepter ce type de prise avec dispositif de 
sécurité. Dans ce cas, contactez un électricien pour faire remplacer la prise murale.  Évitez d’endommager le cordon 

d’alimentation. Protégez le cordon d’alimentation. Assurez-vous qu’on ne marche pas dessus et qu’on ne le pince pas en 
particulier aux prises.  N’UTILISEZ PAS L’APPAREIL si le cordon d’alimentation est endommagé. Pour débrancher 
complètement cet appareil de l’alimentation CA principale, déconnectez le cordon d’alimentation de la prise d’alimentation 

murale. Le cordon d’alimentation du bloc d’alimentation de l’appareil doit demeurer pleinement fonctionnel.

Débranchez cet appareil durant les orages ou si inutilisé pendant de longues périodes.

Service

Consultez un technicien qualifié pour l’entretien de votre appareil. L'entretien est nécessaire quand l'appareil a été endommagé de 
quelque façon que se soit. Par exemple si le cordon d’alimentation ou la prise du cordon sont endommagés, si il y a eu du liquide 
qui a été renversé à l’intérieur ou des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à l'humidité, si il ne 

fonctionne pas normalement, ou a été échappé.

S2125A

Caution: hot surface

Attention: surface chaude

IEC 60417-5041

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS (UL60065)

FOLLOW ALL INSTRUCTIONS

SUIVEZ TOUTES LES INSTRUCTIONS

The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated 
"dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the product

 

 

1. Read these instructions. 
2. Keep these instructions. 
3. Heed all warnings. 
4. Follow all instructions. 
5. Do not use this apparatus near water. 
6. Clean only with dry cloth. 
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A 
grounding type plug has two blades and a third grounding prong. The wide blade or the third prongs are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit 
from the apparatus. 
11. Only use attachments/accessories specified by the manufacturer. 
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution 
when moving the cart/apparatus combination to avoid injury from tip-over. 
13. Unplug this apparatus during lightning storms or when unused for long periods of time. 
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 
power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or 
moisture, does not operate normally, or has been dropped. 

WARNING: 

• To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be 
placed on this apparatus. 
• To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle. 
• The mains plug of the power supply cord or appliance coupler shall remain readily accessible. 

Le symbole représentant un éclair avec une flèche à l’intérieur d’un triangle équilatéral est utilisé pour prévenir l’utilisateur de la 
présence d’une tension électrique dangereuse non isolée à l’intérieur de l’appareil. Cette tension est d’un niveau suffisamment 
élevé pour représenter un risque d’électrocution

Le symbole représentant un point d’exclamation à l’intérieur d’un triangle équilatéral, signale à l’utilisateur la présence d’instructions 
importantes relatives au fonctionnement et à l’entretien de l’appareil dans cette notice d’installation

  

1. Lisez ces instructions. 
2. Conservez ces instructions. 
3. Respecter tous les avertissements. 
4. Suivez toutes les instructions. 
5. N'utilisez pas l'appareil près de l'eau. 
6. Nettoyer uniquement avec chiffon sec. 
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les instructions du fabricant. 
8. Ne pas installer près des sources de chaleur telles que radiateurs, bouches de chaleur, four ou autres appareils (y compris les amplificateurs) 
produisant de la chaleur. 
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de mise à la terre. Une fiche polarisée possède deux lames avec une plus 
large que l'autre. Une prise avec mise à la terre possède deux lames et une troisième tige. La lame large ou la troisième tige sont fournis pour 
votre sécurité. Si la fiche n'entre pas dans votre prise, consultez un électricien pour remplacer la prise obsolète. 
10. Protéger le cordon d'alimentation des piétinements ou pincements en particulier près des fiches, des prises de courant et au point de 
sortie de l'appareil. 
11. Utilisez uniquement les accessoires spécifiés par le fabricant. 
12. Utiliser uniquement avec un charriot, stand, trépied ou une table spécifiée par le fabricant, ou vendus avec l'appareil. 
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé pendant de longues périodes de temps. 
14. Confiez toute réparation à un technicien qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon que ce 
soit;  comme lorsque le cordon d'alimentation ou la fiche est endommagé, lorsque du liquide a été renversé ou des objets sont tombés à l'intérieur, 
lorsque l'appareil a été exposé à la pluie ou l'humidité, ne fonctionne pas normalement, ou est tombé. 

AVERTISSEMENT: 

• Pour réduire les risques d'incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets contenant 
des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débranchez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez un comme dispositif de débranchement, doit rester facilement accessible

CAUTION 

TO PREVENT ELECTRIC SHOCK HAZARD, 

DO NOT CONNECT TO MAINS POWER SUPPLY

WHILE GRILLE IS REMOVED. 

AVIS

POUR PRÉVENIR LES RISQUES D'ÉLECTROCUTION, 

NE PAS RACCORDER A L’ALIMENTATION ÉLECTRIQUE ALORS 

QUE LA GRILLE EST RETIRÉE. 

Summary of Contents for LP-C12

Page 1: ...ada SERVICE MANUAL LP C12 TYPE YS1086 SMT Disclaimer Due to the complex nature of the use of SMT installed components in Yorkville equipment we highly caution all service technicians in attempting to repair or replace SMT factory installed components Many of these components may be glued prior to initial soldering Replacing SMT components requires expensive specialized de soldering equipment and t...

Page 2: ...a propre ventilation Ne procédez pas à l installation près de source de chaleur tels que radiateurs registre de chaleur fours ou autres appareils incluant les amplificateurs qui produisent de la chaleur Les dispositifs marqués d une symbole d éclair sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés pa...

Page 3: ...cene 3 Scene 4 Scene 5 Lights 9 12 5 8 1 4 Lights Lights push to flash push to flash push to flash Scenes Ch 1 4 9 12 Strobe Ch 5 8 9 12 Audio Chase Color Fade ALL CHANNELS Channels 1 4 Blue Channels 5 8 Colors Channels 9 12 White Ch 1 4 5 8 Bar 1 2 3 TMB Bar 1 2 3 TBb Bar 1 2 Ch 9 12 Ch 3 4 5 6 9 12 3 Bands Fast Flash Colors Flash All Colors Flash All RED Red Chase Audio 4 Bands Slow Ch 1 2 7 8 P...

Page 4: ...d Ring 1 8 k Sleeve to GND Audio Input Connector 1 4 inch TRS Data to Lights Connector 3 pin XLR male Communication Protocol Yorkville propietary 31 5 kBits s Power for Controller 24 Volts provided by Yorkville light fixture Maximum Cable Length at least 600 ft Dimensions DWH 13 3 inches x 7 2 inches x 4 inches 33 7 cm x 18 3 cm x 10 1 cm Weight lbs kg 6 5 3 ...

Page 5: ...DETENT P32 3 8 8393 KNOB STYLE 1 GREY 3 9 8806 6 32 X 1 2 PAN PH TAPTITE JS500 10 10 4135 XLR MALE PCB MT VERT 24MM BA SERIES 3 11 4063 1 4IN ISO JCK PCMT VT STER RT SWT 4 12 3389 DPDT PUSH SW PCMT H MOMENTARY 1 13 8649 BUTTON KNOB FLAT BLACK 1 14 4583 ROT GRY 18MM 5BIT ENCODER P33 12 15 4593 ROT SWT 12MM INCR ENCODER P45 12 16 8403 KNOB LED LIGHTS GRAY BODY GRAY TOP 12 17 8522 RUBBER BUMPER WITH ...

Page 6: ...1G 10V0 0W2 5 SMT ZEN 7 7838 MMBT3904 NPN SOT 23 SMT 6 7853 W250 100R 5 1206 SMT RES 9 7854 W125 47R 5 0805 SMT RES 1 7856 W125 470R 5 0805 SMT RES 1 7859 W125 2K2 5 0805 SMT RES 1 7860 W125 4K7 5 0805 SMT RES 5 7866 W125 1M 5 0805 SMT RES 1 7874 _10N 50V 5 CAP 1206 SMT NPO 2 7890 LM2671 3V3 REG 0A5 SMT SO8 1 7901 1W00 22R 5 2512 SMT RES 1 7902 1W00 1K8 5 2512 SMT RES 1 7917 _33U 25V 20 CAP 6 3X5 ...

Page 7: ...NG DIODE P13 4606 ROT GRY 12P 18MM 4BIT ENCODER P23 R56 7676 1 8W 2K0 1 0805 SMT RES C53 7925 22P 50V 5 CAP SMT NPO D51 7947 BAS21DW5T1 SWITCHING DIODE P14 4606 ROT GRY 12P 18MM 4BIT ENCODER P23 R57 7676 1 8W 2K0 1 0805 SMT RES C54 7925 22P 50V 5 CAP SMT NPO D52 7947 BAS21DW5T1 SWITCHING DIODE P15 4434 _10K B LIN 9MM DETENT P32 R58 7621 1 8W 1K0 1 0805 SMT RES C58 5979 100N 25V 5 CAP 0805 SMT X7R ...

Page 8: ... 0805 10K 3V3 R78 W25 0805 10K 10V0 D76 0W2 R57 1 8W 0805 2K0 W125 10K R17 0805 R22 W25 0805 10K GND MMBT3904 Q7 7838 SOT 23 R68 W25 0805 10K C59 50V 10N R7 W250 1206 100R TO LIGHT BARS 25V C25 10U 24V R94 1 8W 0805 1K0 D79 8080 150V 25V C20 10U W125 10K R88 0805 W125 10K R91 0805 C1 100V 100N W125 10K R83 0805 R3 1 8W 1206 619K C3 16V 33U R1 W125 0805 10K00 1 8W 2K0 R6 0805 50V C18 22P 20 PTC R27...

Page 9: ...C71 10U 3V3 CONNECTOR ON MAIN PCB ALL FILTER CAPS CLOSE TO CPU POWER PIN 3V3 N C N C 3V3_FILT TMS BKPT TRST DSCLK QSPI_CS0 R21 W125 0805 470R PTA2 PTA0 2 4 W5 B PTC2 NET00009 NET00010 3V3 GND BAS21DW5T1 D73 A N C CAPS CLOSE TO CPU T B M B P17 A 4434 10K AUTO ADV SCENE EDSI R60 W125 0805 47R QSPI_CS3 PNQ7 GND MCF52252 ALL FILTER CAPS CLOSE TO CPU POWER PIN 16V C61 330N 3V3 VDDPLL In Com Out S14 B F...

Page 10: ...WT PS1 A CH 1 4593 5 4 ROT SWT 12MM INCR ENCODER P45 PS1 B BAS21DW5T1 D37 B BAS21DW5T1 D38 B BAS21DW5T1 D39 B BAS21DW5T1 D40 A BAS21DW5T1 D41 B 5 4 ROT SWT 12MM INCR ENCODER P45 PS10 B 5 4 ROT SWT 12MM INCR ENCODER P45 PS2 B BAS21DW5T1 D44 A BAS21DW5T1 D43 B COM B2 B1 2BIT SWT PS11 A CH 11 4593 5 4 ROT SWT 12MM INCR ENCODER P45 PS11 B COM B2 B1 2BIT SWT PS3 A CH 3 4593 BAS21DW5T1 D45 B BAS21DW5T1 ...

Page 11: ...O 25V C23 100U NC NO COM DOWN UP S17 A 3439 EFFECTS NC NO COM DOWN UP S1 A 3439 SCENE 6 NC NO COM DOWN UP S18 A 3439 ALL WHITE NC NO COM DOWN UP S2 A 3439 SCENE 7 MBRA340T3 D61 Watts 6V3 C24 680U NC NO COM DOWN UP S21 A 3439 BLACK OUT NC NO COM DOWN UP S5 A 3439 SCENE 10 NC NO COM DOWN UP S22 A 3439 AUTO ADV NC NO COM DOWN UP S6 A 3439 SCENE11 NC NO COM DOWN UP S9 A 3439 SCENE 1 NC NO COM DOWN UP ...

Page 12: ...ED DRIVER CONTROL 3V3 GRN LD24 SCENE 2 5908 GRN LD21 SCENE 1 5908 YEL LD11 CH3 INTENSITY 5907 YEL LD9 CH1 INTENSITY 5907 GND C79 50V 100N R11 W125 0805 10K GRN LD25 SCENE 8 5908 LD32 GRN 5908 YEL LD10 CH2 INTENSITY 5907 GRN LD15 SCENE11 5908 GRN LD18 ALL WHT 5908 YEL LD12 CH4INTENSITY 5907 4 SCLK 29 NC 1 GND 32 VCC 2 BLANK 3 XLAT 30 MODE 31 IREF 5 SIN 28 SOUT TLC5922 U16 B 7961 GRN LD31 AUTO ADV 5...

Page 13: ... 39R SI1308EDL 100N 10K 10K 470R 10K TLV2474 619K 100R 1K0 2K0 2N2 100R 33U 10K00 619K 47P MAX5414EUD 4K7 BAS21DW5T1 GRN GRN 10K BLK B 10K SN74AHC138 100U B 10K LM2671M ADJ MBRA340T3 GRN BLU GRN BLU GRN BLU BAS21DW5T1 GRN BLU BAS21DW5T1 GRN BLU BAS21DW5T1 GRN BLU BAS21DW5T1 GRN BLU BAS21DW5T1 BAS21DW5T1 BAS21DW5T1 BLK TLC5922 BAS21DW5T1 BAS21DW5T1 BAS21DW5T1 BAS21DW5T1 BAS21DW5T1 2BIT SWT 2BIT SWT...

Page 14: ...L Changed encoder numbers on SCH to match PCB ML PC8748 Replace 7960 Q1 Q2 Q3 with 8276 GG M1480 PCB_DATABASE_HISTORY LP C12 01APR2011 V01 RELEASED FOR PRODUCTION V02 PC8317 PC8318 add delete move change parts GG 22 SEP 2011 16 FEB 2012 PC8386 Add C27 8105 100n 250V GG PC8748 Remove D62 D64 D66 GG PC8747 Remove D72A and D72B GG FUNCTION KNOB REF MODEL S PART R R R R R R R R F F F F F F F F P P P P...

Reviews: