IMPORTANT SAFETY INSTRUCTIONS

safety-4v3.eps • Oct. 26/05

CAUTION

:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

INSTRUCTIONS PERTAINING TO A

RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS

Read Instructions

The Owner’s Manualshould be read and understood 
before operation of your unit. Please, save these instruc-
tions for future reference.

Packaging

Keep the box and packaging materials, in case the unit 
needs to be returned for service.

Warning

When using electric products, basic precautions should 
always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage 
specified in the owners manual or as marked on the unit. This unit has a 
polarized plug. Do not use with an extension cord or receptacle unless 
the plug can be fully inserted. Precautions should be taken so that the 
grounding scheme on the unit is not defeated.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or 
table. The product may fall, causing serious personal injury and serious 
damage to the product. Use only with cart, stand, tripod, bracket, or 
table recommended by the manufacturer or sold with the product. 
Follow the manufacturer’s instructions when installing the product and 
use mounting accessories recommended by the manufacturer.

The apparatus should not be exposed to dripping or splashing water; 

no objects filled with liquids should be placed on the apparatus.

Terminals marked with the “lightning bolt” are hazardous live; the 

external wiring connected to these terminals require installation by an 
instructed person or the use of ready made leads or cords.

Ensure that proper ventilation is provided around the appliance.
No naked flame sources, such as lighted candles, should be 

placed on the apparatus.

Power Cord

The AC supply cord should be routed so that it is unlikely that it will be 
damaged. If the AC supply cord is damaged DO NOT OPERATE THE UNIT.

Service

The unit should be serviced only by qualified service personnel.

AVIS:

AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,

N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU ARRIERE)

 

NE CONTIENT AUCUNE PIECE

REPARABLE PAR L’UTILISATEUR.

CONSULTEZ UN TECHNICIEN QUALIFIE

POUR L’ENTRETIENT

INSTRUCTIONS RELATIVES AU RISQUE

DE FEU, CHOC ÉLECTRIQUE, OU

BLESSURES AUX PERSONNES

Veuillez Lire le Manuel

Il contient des informations qui devraient êtres comprises 
avant l’opération de votre appareil. Conservez S.V.P. ces 
instructions pour consultations ultérieures.

Emballage

Conservez la boite au cas ou l’appareil devait être 
retourner pour réparation.

Attention:

Lors de l’utilisation de produits électrique, assurez-
vous d’adhérer à des précautions de bases incluant 
celle qui suivent:

Alimentation

L’appareil ne doit être branché qu’à une source d’alimentation 
correspondant au voltage spécifié dans le manuel ou tel qu’indiqué sur 
l’appareil. Cet appareil est équipé d’une prise d’alimentation polarisée. 
Ne pas utiliser cet appareil avec un cordon de raccordement à moins 
qu’il soit possible d’insérer complètement les trois lames. Des 
précautions doivent êtres prises afin d’eviter que le système de mise à 
la terre de l’appareil ne soit désengagé.

Risque

Ne pas placer cet appareil sur un chariot, un support, un trépied ou une 
table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir 
des dommages importants. Utiliser seulement un chariot, un support, 
un trépied ou une table recommandés par le fabricant ou vendus avec 
le produit. Suivre les instructions du fabricant pour installer l’appareil et 
utiliser les accessoires recommandés par le fabricant.

Il convient de ne pas placer sur l’appareil de sources de flammes 

nues, telles que des bougies allumées.

L’appeil ne doit pas être exposé à des égouttements d’eau ou des 

éclaboussures et qu’aucun objet rempli de liquide tel que des vases 
ne doit être placé sur l’appareil.

Assurez que lappareil est fourni de la propre ventilation.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties 

dangereuses au toucher et que les câblages extérieurs connectés à 
ces dispositifs de connection extérieure doivent être effectivés par un 
opérateur formé ou en utilisant des cordons déjà préparés.

Cordon d’Alimentation

Évitez d’endommager le cordon d’alimentation. N’UTILISEZ PAS 
L’APPAREIL si le cordon d’alimentation est endommagé.

Service

Consultez un technicien qualifié pour l’entretien de votre appareil.

Summary of Contents for Coliseum CA12

Page 1: ... Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS WEB ACCESS http www yorkville com CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Quality and Innovation Since 1963 Printed in Canada SERVICE MANUAL CA12 MODEL TYPE YS1048 ...

Page 2: ...CTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT INSTRUCTIONS RELATIVES AU RISQUE DE FEU CHOC ÉLECTRIQUE OU BLESSURES AUX PERSONNES Veuillez Lire le Manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces instructions pour c...

Page 3: ...OURCE SELECTION AVC CONTROL SSM2164 LIMITER CONTROL NJM2761 POWER AMPLIFIER TDA8920BTH OUTPUT SELECTION SW OUTPUT TRANSFORMER OUTPUT TRANSFORMER ZONE 3 AUTO POWER ON OFF CONTROL CH INPUT VOLUME LIMITER SW BRIDGE SW POWER SW REMOTE VOLUME JACK SOURCE SELECTION AVC CONTROL SSM2164 LIMITER CONTROL NJM2761 POWER AMPLIFIER TDA8920BTH OUTPUT SELECTION SW OUTPUT TRANSFORMER OUTPUT TRANSFORMER ZONE 4 AUTO...

Page 4: ...127S01 SCH BUS PW C110 10u 25V D101 1N4148 Q103 2N4401 D111 1N4148 CLIP 1 D106 1N4148 BUS L BUS R D109 1N4148 OutA 2 VCC 1 VREF 5 IN A 3 Sense 6 SW 7 INT 4 IN B 8 OutB 9 GND 10 IC104 NJM2761 3 2 4 IC105A SSM2164 3 2 9 7 8 4 5 1 6 JK103 3 2 1 IC103A TL072 R137 30K C119 100P R133 30K C117 1uF 50V R135 499 C115 560P 6 7 5 IC105B SSM2164 5 6 7 IC103B TL072 R138 30K C120 100P R134 30K C118 1uF 50V R136...

Page 5: ...8 8 4 IC201C 4558 C207 100uF 25V C208 100uF 25V 15V 15V L IN 2 R IN 2 BUS PW C210 10u 25V D201 1N4148 Q203 2N4401 D211 1N4148 CLIP 2 D206 1N4148 D209 1N4148 OutA 2 VCC 1 VREF 5 IN A 3 Sense 6 SW 7 INT 4 IN B 8 OutB 9 GND 10 IC204 NJM2761 11 10 12 IC105C SSM2164 3 2 9 7 8 4 5 1 6 JK203 3 2 1 IC203A TL072 R237 30K C219 100P R233 30K C217 1uF 50V R235 499 C215 560P 14 15 13 IC105D SSM2164 5 6 7 IC203...

Page 6: ...100uF 25V 15V 15V L IN 3 R IN 3 BUS PW C310 10u 25V D301 1N4148 Q303 2N4401 D311 1N4148 CLIP 3 D306 1N4148 D309 1N4148 OutA 2 VCC 1 VREF 5 IN A 3 Sense 6 SW 7 INT 4 IN B 8 OutB 9 GND 10 IC304 NJM2761 3 2 9 7 8 4 5 1 6 JK303 3 2 1 IC303A TL072 R337 30K C319 100P R333 30K C317 1uF 50V R335 499 C315 560P 6 7 5 IC106B SSM2164 5 6 7 IC303B TL072 R338 30K C320 100P R334 30K C318 1uF 50V R336 499 C316 56...

Page 7: ... Q403 2N4401 D411 1N4148 CLIP 4 D406 1N4148 D409 1N4148 OutA 2 VCC 1 VREF 5 IN A 3 Sense 6 SW 7 INT 4 IN B 8 OutB 9 GND 10 IC404 NJM2761 11 10 12 IC106C SSM2164 3 2 9 7 8 4 5 1 6 JK403 3 2 1 IC403A TL072 R437 30K C419 100P R433 30K C417 1uF 50V R435 499 C415 560P 14 15 13 IC106D SSM2164 5 6 7 IC403B TL072 R438 30K C420 100P R434 30K C418 1uF 50V R436 499 C416 560P 8 4 IC403C TL072 C428 0 22uF 50V ...

Page 8: ... 100uF 25V 15V 15V L IN 5 R IN 5 BUS PW C510 10u 25V D501 1N4148 Q503 2N4401 D511 1N4148 CLIP 5 D506 1N4148 D509 1N4148 OutA 2 VCC 1 VREF 5 IN A 3 Sense 6 SW 7 INT 4 IN B 8 OutB 9 GND 10 IC504 NJM2761 3 2 4 IC107A SSM2164 3 2 9 7 8 4 5 1 6 JK503 3 2 1 IC503A TL072 R537 30K C519 100P R533 30K C517 1uF 50V R535 499 C515 560P 6 7 5 IC107B SSM2164 5 6 7 IC503B TL072 R538 30K C520 100P R534 30K C518 1u...

Page 9: ...07 100uF 25V C608 100uF 25V 15V 15V L IN 6 R IN 6 BUS PW C610 10u 25V D601 1N4148 Q603 2N4401 D611 1N4148 CLIP 6 D606 1N4148 D609 1N4148 OutA 2 VCC 1 VREF 5 IN A 3 Sense 6 SW 7 INT 4 IN B 8 OutB 9 GND 10 IC604 NJM2761 11 10 12 IC107C SSM2164 3 2 9 7 8 4 5 1 6 JK603 3 2 1 IC603A TL072 R637 30K C619 100P R633 30K C617 1uF 50V R635 499 C615 560P 14 15 13 IC107D SSM2164 5 6 7 IC603B TL072 R638 30K C62...

Page 10: ...C51 HEF4047BT R55 9 1K C53 100PF NPO C52 0 1uF ZD52 OPEN R54 10R External Clock BACKUP 5V CLOCK C22 4700U 35V C21 4700U 35V VCC VEE GND C18 4700U 35V C17 4700U 35V C20 4700U 35V C19 4700U 35V VEE VCC VEE VCC SWX2 SW115V 230V CX2 0 15UF 275V FUSE 1 T 10A 250V L AC 120V 60Hz AC 230V 50Hz TP 1 TP TP 3 TP TP 2 TP WL 4 TP WL 3 TP WL 2 TP WL 1 TP AC SOCKET L AC SOCKET G AC SOCKET N WL 8 TP WL 7 TP WL 11...

Page 11: ...43 47u 63V 25V 25V GND C740 0 1uF C739 0 1uF 3 2 1 IC701A 4558 R709 10K 5 6 7 IC701B 4558 R701 20K R703 20K R711 10K C701 0 22uF 50V 5 6 7 IC702B 4558 R704 20K R702 20K C702 0 22uF 50V 3 2 1 IC702A 4558 R712 10K R710 10K 1 2 3 4 5 6 7 8 9 10 CNA702 CON10 15V GND Clock L CH IN R CH IN 15V GND R717 1K 15V 8 4 IC701C 4558 C703 100uF 25V C704 100uF 25V 8 4 IC702C 4558 Clock R CH POWER AMPLIFIER GND 1 ...

Page 12: ...5 VCR 5 POW 6 CLIP 6 VCL 6 VCR 6 CLIP 5 POW 5 5V 5V 1 3 2 VR502 B50K FR GAIN 1 3 2 VR501 B50K FL GAIN ZONE 5 R543 4K7 15V LED501 RED GREEN GREEN POWER ON RED CLIP 5V 5V 1 3 2 VR604 B50K FR GAIN 1 3 2 VR603 B50K FL GAIN ZONE 6 R643 4K7 15V LED601 RED GREEN GREEN POWER ON RED CLIP 5V 5V CLIP 4 POW 4 1 3 2 VR102 B50K FR GAIN 1 3 2 VR101 B50K FL GAIN ZONE 1 R143 4K7 15V LED101 RED GREEN GREEN POWER ON...

Page 13: ...712 IC702 R704 R710 Q702 R730 R728 R726 R702 D704 C702 C701 Q701 R729 R727 R725 D703 R715 R733 R713 C715 C716 R731 C713 R714 R716 R732 C722 R734 C751 C754 C714 C721 C753 C739 C735 C736 C740 C727 C718 C729 C719 C731 C728 C724 C725 C730 C732 C737 C738 ...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: