Page 6
OWNERS MANUAL / GUIDE D' OPERATION
POWER:
All values are in WATTS at 1KHz, except FTC 20Hz-20KHz.
Measurements made with regulated 120 VAC sine wave at line cord.
All values are rounded down to the nearest 25 watts.
BURST AVG.
Measured as a 2 cycle burst at 1KHz, 8:1 duty.
(Continuous measurements may require line currents >15 Amps)
ONE CHANNEL DRIVEN (WATTS)
LOAD CONT, AVG,. BURST AVG
PEAK INSTANT FTC 20-20KHz
8 ohms
900
1250 3000
800
4 ohms 1500 2250 6000
1200
BOTH CHANNELS DRIVEN (WATTS)
LOAD CONT, AVG,. BURST AVG
PEAK INSTANT FTC 20-20KHz
8 ohms 750
1200
3000
650
4 ohms
1200
2175
6000
950
BRIDGED (WATTS)
LOAD CONT, AVG,. BURST AVG PEAK INSTANT FTC 20-20KHz
16 ohms
1500 2400 6000 1300
8 ohms
2400 4350
12000
1900
THD DISTORTION: (
measured at 1 dB below rated power, BW = 80 KHz )
LOAD AT 1 KHz 20 Hz - 20 KHz
8 ohms < 0.003 % < 0.04 %
4 ohms < 0.004 %
< 0.05 %
CROSS TALK:
-75 dB below full power at 1KHz,
-60 dB below full power, 20 Hz - 20 KHz.
INPUT IMPEDANCE:
20K ohms balanced, 10 Kohms unbalanced.
INPUT SENSITIVITY:
1.4 VRMS sine wave = full power. ( 36 dB gain )
CONTROLS:
Rotary gain, MONO sw, special subsonic filter sw.
DISPLAYS:
2x CLIP, 2x ACTIVITY, PROTECT, POWER ON. (LEDS)
FREQUENCY RESPONSE
Within 1dB, 20 Hz to 20 KHz, (50 Hz boost sw out)
SPECIFICATIONS