background image

The Lightning Flash with arrowhead symbol within an 

equilateral triangle, is intended to alert the user to the 

presence of uninsulated "dangerous voltage" within the 

product enclosure that may be of sufficient magnitude to 

constitute a risk of shock to persons
The exclamation point within an equilateral triangle is 

intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in the 

literature accompanying the product

 

 

 

 
 

 

IMPORTANT SAFETY INSTRUCTIONS (UL60065) 

1. Read these instructions. 
2. Keep these instructions. 
3. Heed all warnings. 
4. Follow all instructions. 
5. Do not use this apparatus near water. 
6. Clean only with dry cloth. 
7. Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions. 
8. Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat. 
9. Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. A 

grounding type plug has two blades and a third grounding prong. The 

wide blade or the third prongs are provided for your safety. If the provided 

plug does not fit into your outlet, consult an electrician for replacement of 

the obsolete outlet. 
10. Protect the power cord from being walked on or pinched particu-

larly at plugs, convenience receptacles, and the point where they 

exit from the apparatus. 
11. Only use attachments/accessories specified by the manufacturer. 
12. Use only with the cart, stand, tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. When a cart is used, use caution 

when moving the cart/apparatus combination to avoid injury from tip-over. 
13. Unplug this apparatus during lightning storms or when unused for 

long periods of time. 
14. Refer all servicing to qualified service personnel. Servicing is required 

when the apparatus has been damaged in any way, such as power-

supply cord or plug is damaged, liquid has been spilled or objects have 

fallen into the apparatus, the apparatus has been exposed to rain or 

moisture, does not operate normally, or has been dropped. 

WARNING: 

• To reduce the risk of fire or electric shock, do not expose this apparatus 

to rain or moisture and objects filled with liquids, such as vases, should 

not be placed on this apparatus. 
• To completely disconnect this apparatus from the ac mains, disconnect 

the power supply cord plug from the ac receptacle. 
• The mains plug of the power supply cord or appliance coupler shall 

remain readily accessible. 

Le symbole représentant un éclair avec une flèche à l’intérieur 

d’un triangle équilatéral est utilisé pour prévenir l’utilisateur de la 

présence d’une tension électrique dangereuse non isolée à 

l’intérieur de l’appareil. Cette tension est d’un niveau suffisam-

ment élevé pour représenter un risque d’électrocution
Le symbole représentant un point d’exclamation à l’intérieur 

d’un triangle équilatéral, signale à l’utilisateur la présence 

d’instructions importantes relatives au fonctionnement et à 

l’entretien de l’appareil dans cette notice d’installation

 

 
 

1. Lisez ces instructions. 
2. Conservez ces instructions. 
3. Respecter tous les avertissements. 
4. Suivez toutes les instructions. 
5. N'utilisez pas l'appareil près de l'eau. 
6. Nettoyer uniquement avec chiffon sec. 
7. Ne bloquez pas les ouvertures de ventilation. Installer en suivant les 

instructions du fabricant. 
8. Ne pas installer près des sources de chaleur telles que radiateurs, 

bouches de chaleur, four ou autres appareils (y compris les amplifica-

teurs) produisant de la chaleur. 
9. N'annulez pas l'objectif sécuritaire de la fiche polarisée ou de la tige de 

mise à la terre. Une fiche polarisée possède deux lames avec une plus 

large que l'autre. Une prise avec mise à la terre possède deux lames et 

une troisième tige. La lame large ou la troisième tige sont fournis pour 

votre sécurité. Si la fiche n'entre pas dans votre prise, consultez un 

électricien pour remplacer la prise obsolète. 
10. Protéger le cordon d'alimentation des piétinements ou pince-

ments en particulier près des fiches, des prises de courant et au 

point de sortie de l'appareil. 
11. Utilisez uniquement les accessoires spécifiés par le fabricant. 
12. Utiliser uniquement avec un charriot, stand, trépied ou une table 

spécifiée par le fabricant, ou vendus avec l'appareil. 
13. Débranchez l'appareil durant un orage ou lorsqu'il reste inutilisé 

pendant de longues périodes de temps. 
14. Confiez toute réparation à un technicien qualifié. Une réparation est 

nécessaire lorsque l'appareil a été endommagé de quelque façon que ce 

soit;  comme lorsque le cordon d'alimentation ou la fiche est endom-

magé, lorsque du liquide a été renversé ou des objets sont tombés à 

l'intérieur, lorsque l'appareil a été exposé à la pluie ou l'humidité, ne 

fonctionne pas normalement, ou est tombé. 

AVERTISSEMENT: 

• Pour réduire les risques d'incendie ou de choc électrique, ne pas 

exposer cet appareil à la pluie ou à l'humidité et ne placez pas d’objets 

contenant des liquides, tels que des vases, sur l’appareil.
• Pour isoler totalement cet appareil de l'alimentation secteur, débran-

chez totalement son cordon d'alimentation du réceptacle CA.
• La prise du cordon d’alimentation ou du prolongateur, si vous en utilisez 

un comme dispositif de débranchement, doit rester facilement accessible

UL60065 Safety Instructions Page-2v0

CAUTION 

TO PREVENT ELECTRIC SHOCK HAZARD, 

DO NOT CONNECT TO MAINS POWER SUPPLY

WHILE GRILLE IS REMOVED. 

AVIS

POUR PRÉVENIR LES RISQUES 

D'ÉLECTROCUTION, 

NE PAS RACCORDER A L’ALIMENTATION ÉLEC-

TRIQUE ALORS QUE LA GRILLE EST RETIRÉE. 

Summary of Contents for AP4K YS1112

Page 1: ...OWNER S MANUAL MANUELDEL UTILISATEUR 4K PROFESSIONAL POWER AMPLIFIER TYPE YS1112 ...

Page 2: ...ed or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped AVIS AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT CE PRODUIT EST POUR L USAGE À L INTÉREUR SEULEMENT Instr...

Page 3: ...résence d une tension électrique dangereuse non isolée à l intérieur de l appareil Cette tension est d un niveau suffisam ment élevé pour représenter un risque d électrocution Le symbole représentant un point d exclamation à l intérieur d un triangle équilatéral signale à l utilisateur la présence d instructions importantes relatives au fonctionnement et à l entretien de l appareil dans cette noti...

Page 4: ...ed source via the XLR input you must connect the signal to Pin 2 and ground BOTH Pin 1 and Pin 3 Remote Referencing You can approach balanced performance with unbalanced sources by utilizing the remote reference feature of the AP4K Connect a balanced cable to the AP4K just as you would if you were running a balanced line At the other end connect Pin 3 and Pin 1 together or connect ring to sleeve i...

Page 5: ...4K is required to restore proper operation The PROTECT CLIP LED will stay on if the amplifier has overheated Check the speaker load impedance and any restrictions to air flow at the air intake or exhaust vents of the amplifier 2 ohm 4 ohm Mode The AP4K is equipped with the capability of working in two different modes If the amplifier is connected to speaker loads of 4 ohms or above the switch on t...

Page 6: ...e end of the post or you can insert the wire into the side of the binding post There are two Speakon connectors The Speakons are connected to the amplifier s outputs whether the amplifier is in stereo mono or bridge modes Each Speakon output connector output A and output B is wired in parallel with it s respective binding posts for two channel two cable connections figure 1 Speakon output A also d...

Page 7: ...edance Bal Unbal ohms 10 000 5 000 10 000 5 000 Input Sensitivity Vrms For Full Power Out V 4 1 V 0 1 Max Voltage Gain dB 36 CMRR 60Hz min typ 48 56 dB Stereo Bridge S B S B Protection DC Load Thermal Limiter Peak High Pass Filter 50Hz 18dB Octave Cooling Internal Fans Cooling Path Front to Rear Fan Filter User Serviceable Inputs XLR 2 Inputs 1 4 inch Jacks 4 Outputs Speakon 4 pin 2 Outputs Bindin...

Page 8: ...e XLR du canal correspondant la bague à la tige 3 et le manchon à la tige 1 La tige 2 est en phase la tige 3 est en opposition de phase à 180 degrés et la tige 1 est branchée à la masse Utilisation De Câble De Pouce Asymétrique Des prises phono à circuit simple peuvent être utilisées pour raccorder des câbles de pouce avec signaux asymétriques NOTE IMPORTANTE Pour assurer un bon fonctionnement l u...

Page 9: ...t parleurs ou dans le câblage des haut parleurs Aucun réglage au AP4K n est requis pour restaurer le mode d opération Si l amplificateur a surchauffé la DEL PROTECT CLIP reste allumé Vérifier l impédance de charge et toute restriction aux prises d air ou aux orifices d échappement Mode 2 ohm 4 ohm Le AP4K dispose de la capacité de travailler dans deux modes différents Si l amplificateur est connec...

Page 10: ...ixe avec moniteurs de studio de 4 ou 8 ohms est sans parallèle Branchements de Sorties AVERTISSEMENT Lorsqu utilisé à pleine puissance en mode En Pont il y a plus de 200 Vrms entre les bornes de sortie Ceci représente un risque considérable de choc électrique Il est donc très important de faire bien attention lorsque vous y branchez des haut parleurs Assurez vous qu aucun brin exposé de conducteur...

Page 11: ... Sensibilité d Entrée Vrms pour pleine puissance à la sortie 1 0 V 1 4 V Gain maximum de voltage dB 36 Rapport de réjection en mode commun 60Hz min typ 48 56 dB Stéréo En Pont S P S P Protection CC Charge ThermiqueL Limiteur Pointe Filtre Passe Haut 50Hz 18dB Octave Refroidissement Ventilateurs InternesA Acheminement du Refroidissement Devant à Arrière Filtre du Ventilateur Entretient par l Utilis...

Page 12: ...9 ...

Page 13: ... votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de la série de moniteurs...

Page 14: ...al Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners AP4K 1v2 September 30 2014 ...

Reviews: