background image

5

Specifications

Amplifier class

H

Coninuous Average Power @ 8 ohms BCD (Watts)

1250 (x2)

Coninuous Average Power @ 4 ohms BCD (Watts)

2000 (x2)

Coninuous Average Power @ 2 ohms BCD (Watts)

NA

Continuous Average Power Bridged BCD (Watts)

NA

Burst Average Power @ 8 ohms BCD (Watts)

2000 (x2)

Burst Average Power @ 4 ohms BCD (Watts)

3625 (x2)

Burst Average Power @ 2 ohms BCD (Watts)

NA

Burst Average Power Bridged BCD (Watts)

NA

Frequency Response (Hz, +/- 1dB)

20-20,000

Hum and Noise (un / Aweighted -dB)

0.971698113

THD -1kHz- 4 ohms

0.01%

THD - 20Hz-20kHz, 4 ohms

less than 0.1%

Slew Rate (V/uS)

50

Damping Factor (30 Hz - 400 Hz @ 8 ohms)

600

Crosstalk (1kHz / 20Hz-20kHz)

-75 / -60 dB

Input Impedance - Bal/Unbal (ohms)

20,000/10,000

Input Sensitivity (Vrms) For Full Power Out

1.4 V

Max Voltage Gain (dB)

41

CMRR @ 60Hz (min/typ)

48/56 dB

Stereo / Mono / Bridge (S/M/B)

S/M

Protection

DC,Load,Thermal

Limiter

Peak

High Pass Filter

40Hz, 12dB Octave

Cooling

Dual Internal Fans

Cooling Path

Front to Rear

Fan Filter

2x User Serviceable

Inputs - XLR

2

Inputs - 1/4 inch Jacks

2

Outputs - Speakon 4-pin

2

Outputs - Binding Post

2

Power Consumption (typ/max)

1800/3000 Watts

Rack Spaces

3

Transformer Type

Toroidal

Exterior Finish

Baked, Black Painted

Dimensions (DWH /D fm ears, inches)

19 x 18.5 x 25 x 17.6

Dimensions (DWH /D fm ears, cm)

48.3 x 47 x 13.3 x 44.7

Weight (lbs / kg)

67 / 31

AP 6040

Summary of Contents for AP 6040 Professional Series

Page 1: ...AP6040 MODEL TYPE YS6040 ...

Page 2: ... spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped AVIS AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT Instructions relatives au risque de feu choc élect...

Page 3: ...ONE plugs may be used to connect unbalanced signals IMPORTANT NOTE Such plugs effectively connect the ring terminal to sleeve ground so they work correctly However if you use a Stereo 1 4 inch PHONE plug on an unbalanced line you MUST short the Ring terminal to the sleeve terminal oth erwise the sensitivity will be 6dB lower than is specified The same applies to the XLR input To connect an unbal a...

Page 4: ...witch to the IN position completely disables both limiters Protect LED In the event of a shorted load or a load which is of too low an impedance for the amplifier to handle the PROTECT LED will flash alternately on and off at about 3 second intervals The sound may come on and off at second intervals In this case the fault is in the speakers or the speaker cables and should be located and remedied ...

Page 5: ...ry equipped with fan filters mounted on the air intake grills located on the amplifier s front panel Regular cleaning of these filters will increase the amplifier s long term reliability The filters should be removed and washed at the first sign of visible clogging This will typically occur every four to six weeks depend ing on use and environment Replacement filters are inexpensive and can be ord...

Page 6: ...0 3600 All values are in WATTS Measurements were made at the 0 1 distortion point Some CONTINUOUS AVERAGE POWER measurements required line currents greater than 30 Amps The amplifier under test was plugged into an IDEAL POWER LINE consisting of a REGULATED 120 VAC RMS 60 Hz pure sine wave Ordinary AC wall outlet lines will always exhibit varying and unpredictable amounts of sag To produce objectiv...

Page 7: ... 50 Damping Factor 30 Hz 400 Hz 8 ohms 600 Crosstalk 1kHz 20Hz 20kHz 75 60 dB Input Impedance Bal Unbal ohms 20 000 10 000 Input Sensitivity Vrms For Full Power Out 1 4 V Max Voltage Gain dB 41 CMRR 60Hz min typ 48 56 dB Stereo Mono Bridge S M B S M Protection DC Load Thermal Limiter Peak High Pass Filter 40Hz 12dB Octave Cooling Dual Internal Fans Cooling Path Front to Rear Fan Filter 2x User Ser...

Page 8: ... la prise sur chaque canal est branchée à la tige 2 de la prise XLR du canal correspondant la couronne à la tige 3 et le manchon à la tige 1 La tige 2 est en phase la tige 3 est en opposition de phase et la tige 1 est branché à la masse L utilisation des entrées symétriques vous permettra d obtenir une meilleure performance signal bruit particulièrement lors de montage à plusieurs amplificateurs E...

Page 9: ...n désengage completement chaque limiteur DEL Protectrice Lorsqu une charge court circuitée ou une charge dont l impédance est inférieure à ce que l amplificateur peut supporter se présente à celui ci la DEL protectrice clignote à des intervalles d environ 7 secondes Le son peut être coupé à la même fréquence Dans ce cas on doit localiser et régler le problème qui réside dans les haut parleurs ou d...

Page 10: ...rer sans filtre mais devrait être net toyé par un technicien qualifié lorsque la poussière devient visible sur les nageoires du dissipateur de chaleur Note Dans un emplacement exceptionnellement pous sièreux si vous ne prévoyez pas faire d inspections régulière du filtre enlevez le Cela prolongera le temps de fonctionnement avant fermeture thermique Branchemments de Sorties AVERTISSEMENT Plus de 1...

Page 11: ...1dB 20 20 000 Bruit et Bourdonnement non A Pondéré dB 0 971698113 DHT 1kHz 4 ohms 0 01 DHT 20Hz 20kHz 4 ohms Moins de 0 1 Vitesse de propagation V µS 50 Facteur d Amortissement 30 Hz 400 Hz 8 ohms 600 Couplage parasite 1kHz 20Hz 20kHz 75 60 dB Impédance d Entrée symétrique asymétrique ohms 20 000 10 000 Sensibilité d Entrée Vrms pour pleine puissance à la sortie 1 4 V Gain maximum de voltage dB 41...

Page 12: ...10 ...

Page 13: ...re de faire enregistrer votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception d...

Page 14: ...ial Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners ap6040 00 3v8 Feb 5 2009 ...

Reviews: