19
AC application
1. Start the engine and make sure only the output indicator light (green) comes on.
2. Confirm that the appliance to be used is switched off, and plug in the appliance.
■
Substantial overloading that continuously lights the overload indicator light (red) may damage
the generator. Marginal overloading that temporarily lights the overload indicator light (red)
may shorten the service life of the generator.
■
Be sure that all appliances are in good working order before connecting them to the generator.
If an appliance begins to operate abnormally, becomes sluggish, or stops suddenly, turn off
the generator engine switch immediately. Disconnect the appliance and examine it for signs
of malfunction.
3. In order to insure the optimum output and the maximum service life of the generator, the
generator should run at a 50% load for the first 20 hours.
Stop the engine if the overload indicator light (red) comes on and investigate the overload source
■
Before connecting an appliance to the generator, check that it is in good order and that its
electrical rating does not exceed that of the generator. Connect the power cord of the
appliance and start the engine.
Overload light(Red)
Output light(Green)