Johnson Controls Ducted Systems
Nomenclature
Z W TA5 N 16 A 2 A A C 2 1 B A 9
Product Category
Z = A/C, Single Pkg., R-410A
Product Generation
8 = Eighth Generation
9 = Ninth Generation
06 = 60 MBH Input (TA3, TA4)
08 = 80 MBH Input (TA3, TA4, TA5)
11 = 120 MBH Input (TA3, TA4, TA5)
16 = 160 MBH Input (TA5)
03 = 3 KW (TA3)
06 = 6 KW (TA3, TA4, TA5)
08 = 9 KW (TA3, TA4, TA5)
15 = 15 KW (TA3, TA4, TA5)
20 = 20 KW (TA4, TA5)
23 = 24 KW (TA5)
Natural Gas Heat Options
Electric Heat Options
Nominal Cooling Capacity
TA3 = 3 Ton
TA4 = 4 Ton
TA5 = 5 Ton
Product Identifier
Voltage
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
VFD Options
A = None
B = VFD,VAV
C = VFD, w/Bypass, VAV
D = Cust Sup VFD,VAV
E = VFD, IntelliSpeed
F = VFD ,w/Bypass, Intellispeed
G = Cust Sup VFD, Intellispeed
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options
Filter Options
1 = 2" Throwaway Filters
2 = 2" Pleated Filters (Merv 8)
3 = 2" Cleanable Filters
4 = 4" Pleated Filters (Merv 13)
A = None
C = BACnet MSTP,Modbus,N2 COM Card
E = Verasys Single Zone
G = Verasys Change Over Bypass
H = Hnywll Excel 10 Ctrl, DFS, APS
J = Verasys VAV
N = Novar UCM Ctrl, DFS, APS
P = CPC Control, DFS, APS
Control Options
3-12.5 Ton Model Number Nomenclature
W = 12.2 EER
Airflow
A = Std. Motor
D = Std. Motor/Motorized Damper (Downflow Only)
H = Std Motor/Low Leak Econ/Barometric Relief (Downflow
& Horizontal End Return Only)
J = Std Motor/Low Leak Econ/Power Exhaust (Downflow
& Horizontal End Return Only)
N = Hi Static
R = Hi Static/Motorized Damper (Downflow Only)
V = Hi Static Mtr/Low Leak Econ/Barometric Relief
(Downflow & Horizontal End Return Only)
W = Hi Static Mtr/Low Leak Econ/Power Exhaust
(Downflow & Horizontal End Return Only)
Heat Type
C = Cooling Only. No heat installed
N = Alum Steel, Two Stage
S = Stainless Steel Two Stage
Nominal Heat Capacity (Unit Size Allowed)
Cooling
00 = Cooling Only
Configuration Options
1 = Bottom Drain Composite-STD
2 = Hot Gas Bypass
3 = SS Drain Pan No/HGB
4 = SS Drain Pan W/HGB
5 = Reverse Drain Pan No/HGB
6 = Reverse Drain Pan W/HGB
A = No Options
B = Phase Monitor (PM)
C = Coil Guard (CG)
D = Dirty Filter Switch (DFS)
E = PM & CG
F = PM & DFS
G = CG & DFS
H = PM, CG, & DFS
Additional Options
Coated Coils
A = Un-Coated
B = E-Coat Cond & Evap Coils
C = E-Coat Condenser Coil
D = E-Coat Evaporator Coil