Johnson Controls Unitary Products
632151-YTG-A-1010
— = Not applicable.
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
W
STAGE
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENSIBLE
1 PH HP WITH MV - VARIABLE SPEED
YZF02413(C)
MV12B
17
FC/MC35B
800
23.6
17.8
15.00
12.50
MV12B
17
FC/MC43B
800
24.0
18.6
16.00
13.00
YZF03013(C)
MV12B
17
FC/MC43B
1000
28.8
21.8
16.00
13.00
MV16C
21
FC/MC43C
1000
28.8
22.0
16.00
13.00
YZF03613(C)
MV12D
24
FC/MC48D
1160
34.8
26.0
15.00
12.50
MV16C
21
FC/MC48C
1200
34.6
25.8
15.00
12.50
MV12D
24
FC/MC60D
1135
34.6
25.6
15.00
12.50
YZF04213(C)
MV20D
24
FC/MC62D
1400
41.0
28.0
15.00
12.50
YZF04813(C)
MV20D
24
FC/MC62D
1630
46.5
34.8
15.00
12.50
MV20D
24
FC64D
1630
48.0
36.8
15.00
12.50
YZF06013(C)
MV20D
24
FC/MC62D
1
1075
46.5
29.8
15.00
20.80
2
1630
56.0
39.0
11.80
MV20D
24
FC64D
1
1075
48.0
31.2
15.00
21.60
2
1630
57.5
40.5
12.00
1 PH HP WITH AV / SV / F*FV - VARIABLE SPEED
YZF02413(C)
AV*36
21
–
–
725
23.8
17.4
16.00
13.00
YZF03013(C)
AV*36
21
–
–
960
28.8
21.6
16.00
13.00
YZF03613(C)
AV*48
24
–
–
1220
35.2
26.6
15.00
12.50
1 PH HP WITH AHP/ SHP / AHX / F*FP
YZF02413(C)
AHX30
17
–
–
835
23.8
18.1
15.00
12.50
AHX36
21
–
–
820
24.0
18.1
15.00
12.50
F6FP030
17
–
–
850
23.8
17.9
15.00
12.50
F6FP036
21
–
–
855
23.8
18.0
15.00
12.50
YZF03013(C)
AHX36
21
–
–
1005
28.8
22.0
16.00
13.00
YZF03613(C)
AHX42
21
–
–
1200
35.2
26.4
15.00
12.50
AHX48
24
–
–
1255
35.4
27.2
15.00
12.50
F6FP042
24
–
–
1290
35.2
27.2
15.00
12.50
F6FP048
24
–
–
1125
34.8
25.6
15.00
12.50
YZF04213(C)
AHX60
24
–
–
1440
41.5
28.0
15.00
12.50
F6FP060
24
–
–
1475
41.5
28.6
15.00
12.50
YZF04813(C)
AHX60
24
–
–
1570
46.5
35.2
15.00
12.50
F6FP060
24
–
–
1570
46.5
35.0
15.00
12.50
YZF06013(C)
AHX60
24
–
1
1255
48.0
31.6
15.00
20.65
2
1930
57.0
41.5
11.60
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.