539163-YTG-D-0713
2
Johnson Controls Unitary Products
NOTES:
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
LEFT SIDE
RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
30.25”
28.5”
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
A
B
C
YPLC060A12MP12C
1200
A
14 1/2
13 1/4
10.3
YPLC080B12MP12C
1200
B
17 1/2
16 1/4
11.8
YPLC080C16MP12C
1600
C
21
19 3/4
13.6
YPLC100C16MP12C
1600
C
21
19 3/4
13.6
YPLC100C20MP12C
2000
C
21
19 3/4
13.6
YPLC120C20MP12C
2000
C
21
19 3/4
15.8
Ratings & Physical / Electrical Data
Models
Input
Max/Min
Output
Max/Min
AFUE
Nominal
Airflow
Total
Unit
Amps
Air Temp. Rise
Max Input
Air Temp.
Rise Min Input
MBH
MBH
CFM
°F
°F
YPLC060A12MP12C
60/30
47/24
80.0
1200
7.0
30-60
20-50
YPLC080B12MP12C
80/40
62/32
80.0
1200
7.5
40-70
20-50
YPLC080C16MP12C
80/40
62/32
80.0
1600
10.0
35-65
20-50
YPLC100C16MP12C
100/50
78/40
80.0
1600
10.0
35-65
20-50
YPLC100C20MP12C
100/50
78/40
80.0
2000
12.0
35-65
20-50
YPLC120C20MP12C
120/60
95/48
80.0
2000
12.0
45-75
25-55
Models
Max. Outlet
Air Temp
Blower
Blower
Wheel Size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
Approximate
Operating Weights
°F
HP
Amps
Lbs
YPLC060A12MP12C
160
1/2
4.8
11 x 8
15
14
94
YPLC080B12MP12C
170
1/2
4.8
11 x 8
15
14
103
YPLC080C16MP12C
165
3/4
7.5
11 x 10
15
14
114
YPLC100C16MP12C
165
3/4
7.5
11 x 10
15
14
118
YPLC100C20MP12C
165
1
14.5
11 x 11
20
12
122
YPLC120C20MP12C
175
1
14.5
11 x 11
20
12
129