Johnson Controls Unitary Products
5
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
WIDTH
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.
14 SEER HP WITH AIR HANDLERS
YHJD42S41S7
MX20DN21
24.5
FC/MC48D
1375
41.5
31.6
14.00
12.00
YHJD42S41S7
MX20DN21
24.5
FC/MC60D
1375
40.5
31.8
14.00
12.00
YHJD48S41S7
AHE48D
24.5
–
1600
46.0
35.2
14.00
12.00
YHJD48S41S7
AHE60D
24.5
–
1550
48.0
35.6
14.00
12.00
YHJD48S41S7
AHV48D
24.5
–
1300
46.0
32.4
14.00
12.00
YHJD48S41S7
AHV60D
24.5
–
1340
47.0
33.4
14.00
12.00
YHJD48S41S7
MV16C
21.0
FC60C
1400
46.0
35.0
14.00
12.00
YHJD48S41S7
MV20D
24.5
FC/MC60D
1400
46.0
33.4
14.00
12.00
YHJD48S41S7
MV20D
24.5
FC/MC62D
1400
47.5
33.2
14.00
12.00
YHJD48S41S7
MX16CN21
21.0
FC60C
1400
46.0
33.2
14.00
11.75
YHJD48S41S7
MX20DN21
24.5
FC/MC60D
1375
46.0
33.2
14.00
12.00
YHJD48S41S7
MX20DN21
24.5
FC/MC62D
1400
47.5
34.0
14.00
12.00
YHJD60S41S7
AHE60D
24.5
–
1835
57.0
42.5
14.00
12.00
YHJD60S41S7
AHV60D
24.5
–
1635
57.0
40.5
14.00
12.00
YHJD60S41S7
MV20D
24.5
FC/MC62D
1855
57.0
42.5
14.00
12.00
YHJD60S41S7
MV20D
24.5
FC64D
1855
57.0
42.0
14.00
12.00
YHJD60S41S7
MX20DN21
24.5
FC/MC62D
1750
57.0
43.5
14.00
12.00
YHJD60S41S7
MX20DN21
24.5
FC64D
1750
57.0
43.0
14.00
12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at
those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the to-
tal electric power input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
571209-YTG-F-0615