1. If the supply cord is damaged, it must be replaced by the manufacturer or its

service agent or a similar quali ed person. The type of connecting wire is

H05RN-F or H07RN-F.

2. If the fuse on PC board is broken please change it with the type of 

T. 3.15A/250V.

3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
5. A breaker should be incorporated into xed wiring. The breaker should be

all-pole switch and the distance between its two contacts should be not less
than 3mm.

Outdoor unit

Indoor unit

A

B

Outdoor unit

Indoor unit

A

B

A

B

Outdoor unit

Indoor unit

Oil trap

Outdoor unit

Install according to

Drawing for the installation of indoor and outdoor units

To bend  a  pipe, give the roundness as large as possible not to crush the pipe ,

and the bending radius should be 30 to 40 mm or longer.

Connecting the pipe of gas side rst makes working easier.
The connection pipe is specialized for R410A.

Use the same method on indoor unit. Loosen the screws on terminal block and

insert the plugs fully into terminal block, then tighten the screws.

Insert the cable according to terminal number in the same manner as the indoor
unit.
If wiring is not correct, proper operation can not be carried out and controller
may be damaged.
Fix the cable with a clamp.

Installation of Outdoor Unit

Half union

Flare nut

Torque wrench

CAUTION

Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
The standard pipe length is 5m. If it is over 7m, the function of the unit will be
affected. If the pipe has to be lengthened, the refrigerant should be charged,

according to 20 g/m. But the charge of refrigerant must be conducted by profes-

sional air conditioner engineer. Before adding additional refrigerant, perform air
purging from the refrigerant pipes and indoor unit using a vacuum pump,then

Spanner

Forced fastening without careful centering may
damage the threads and cause  a  leakage of gas.

Pipe Diameter( )

Fastening torque

Liquid side6.35mm(1/4")

18N.m

Liquid/Gas side9.52mm(3/8")

42 N.m

Gas side 12.7mm(1/2")

55N.m

Gas side 15.88mm(5/8")

60 N.m

Max.Elevation:

In case the elevation A is more
than 5m, oil trap shoud be
installed every 5~7m
Max. Length:
In case the pipe length  B  is
m
diameter is 6.35mm the refrigerant 
should be charged, according to 20g/m
;if the liquid diameter is 6.35mm the
refrigerant should be charged, 
according to 50g/m

ore than 7m, if the liquid pipe 

Connection of pipes

charge additional refrigerant.

Connection

If the drain-elbow is used,

please attach it as gure. (Note:
Only for heat pump unit.)

Detach the service port’s cap of

1.

3-way valve, the valve rod’s cap for 2-way valve

and 3-way’s, connect the service port into the projection of charge hose (Iow)

for gaugemanifold. Then connect the projection of charge hose (center) for gau-

gemanifold into vacuum pump.

Open the handle at Iow in

2.

gaugemanifold, operate vacuum pump. If the scale-

moves of gause (Iow) reach vacuum condition in a moment, check 1. again.

Vacuumize for over 15min.And check the level gauge which should read -0.1MPa

3.

(76 cm Hg) at Iow pressure side. After the completion of vacuumizing, close the

handle ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check

condition of the scale and hold it for 1-2min. If the scale-moves back in spite of

tightening, make aring work again, the return to the beginning of 3 .

Attaching Drain-Elbow

Purging Method:To use vacuum pump

Open the valve rod for the 2-way valve to an angle of

4.

anticlockwise 90 degrees.

After 6 seconds, close the 2-way valve and make the inspection of gas leakage.

Amax=15m

Bmax=25m

Indoor unit

Outdoor unit

2

 3G2.5mm

-mod     18:

2

1

/

POWER
SUPPLY

BL

BR

Y/G

Indoor unit

Outdoor unit

6G0.75mm

Power cable:

3G2.5mm

<+)<+%$+$;

<+)<+%$+$;

<+)<+%$+$;

Power cable:

3G2.5mm

Installations

14

Summary of Contents for YH9FYH24BAH-A-X

Page 1: ...SERVICE MANUAL High Wall Fixed R 410A 60Hz YH9FYH24BAH A X Read this manual before installation and operation Make sure that it is well kept for later reference ...

Page 2: ...on 1 2 Specifications 7 3 Sensors list 8 4 Piping diagrams 9 5 Operation range 10 6 Wiring diagrams 7 Dimensional drawings 8 CHnter of gravity 9 Installations 10 Service Diagnosis 11 Performance and cXrves diagrams 11 21 17 13 12 12 ...

Page 3: ...ling the equipment for a repair Working on the equipment that is connected to a power supply can cause an electrical shook If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits do not touch any electrically charged sections of the equipment If the refrigerant gas discharges during the repair work do not touch the discharging refrigerant gas The refrig...

Page 4: ...n enclosed room can cause oxygen deficiency 1 1 2 Cautions Regarding Products after Repair Warning Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to conduct repair work Never attempt to modify the equipment The use of inappropriate parts or tools can cause an electrical shock excessive heat generation or fire When relocating the equipment make s...

Page 5: ...cable can cause an electrical shock or fire Placing heavy items on the power cable and heating or pulling the power cable can damage the cable Do not mix air or gas other than the specified refrigerant R 410A R22 in the refrigerant system If air enters the cooling system an excessively high pressure results causing equipment damage and injury If the refrigerant gas leaks be sure to locate the leak...

Page 6: ...l shock or fire If the power cable and lead wires have scratches or deteriorated be sure to replace them Damaged cable and wires can cause an electrical shock excessive heat generation or fire Warning Do not use a joined power cable or extension cable or share the same power outlet with other electrical appliances since it can cause an electrical shock excessive heat generation or fire Caution Che...

Page 7: ...f the reader to specific information The meaning of each icon is described in the table below 1 2 5 Using Icons List Icon Type of Information Description Note Note A note provides information that is not indispensable but may nevertheless be valuable to the reader such as tips and tricks Caution Caution A caution is used when there is danger that the reader through incorrect manipulation may damag...

Page 8: ...evel B d r e w o p d n u o S ELECTRICAL SPECIFICATIONS g n i t a e h g n i l o o c 10 9 A t n e r r u c g n i n n u r l a n i m o N Maximum running current A 14 6 TECHNICAL SPECIFICATIONS PARTS g n i t a e h g n i l o o c Compressor r o s s e r p m o C y r a t o R e p y T ASH232SN l e d o M 2350 W t u p t u o r o t o M Oil type HAF68D1 or equivalent L e m u l o v e g r a h c l i O Fan n a f l a i ...

Page 9: ...erence m 15 Chargeless m Amount of Additional Charge of Refrigerant g m Note the data are based on the conditions shown in the table below h t g n e l g n i p i P g n i t a e h g n i l o o c Indoor WB Outdoor WB 3 Sensors list type Description Qty 1 i t c e t e d r o f d e s u s t I r o s n e s t n e i b m A e d i s r o o d t u o f o e r u t a r e p m e t g n Suction sensor Its used for detecting ...

Page 10: ...Piping diagrams 8 ...

Page 11: ...Operation range 9 ...

Page 12: ...Wiring diagrams 6 Wiring diagrams 10 ...

Page 13: ...Dimensinal drawings 7 Dimensional drawings 8 Center of gravity 730mm 308mm 810mm 860mm 308mm 860mm 730mm 308mm 338 3mm 284 8mm 113 7mm 11 ...

Page 14: ... wall place where the indoor unit can receive signals when the uorescent lamps in the room are lightened Outdoor Unit Place which is less affected by rain or direct sunlight and is suf ciently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is availabl...

Page 15: ... unit and pull it out on the front side then connect them 3 Coat the aring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure xing with adhesive tape Fixing the indoor unit body Hang surely the unit body onto the upper notches of the mounting plate Move the body from side to side to verify its secure xing In order to x th...

Page 16: ...orm air purging from the refrigerant pipes and indoor unit using a vacuum pump then Spanner Forced fastening without careful centering may damage the threads and cause a leakage of gas Pipe Diameter Fastening torque Liquid side6 35mm 1 4 18N m Liquid Gas side9 52mm 3 8 42 N m Gas side 12 7mm 1 2 55N m Gas side 15 88mm 5 8 60 N m Max Elevation In case the elevation A is more than 5m oil trap shoud ...

Page 17: ...type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker 4 Flare pipe Lean Damage of are Crack Partial Too outside t c e r r o c n I t c e r r o C On Drainage It becomes high midway The gap with the ground is too smal There is the bad smell from a ditch It waves The end is imm ersed in water Please install the drain hose so as to be downward slope without fail Please don t do the drain...

Page 18: ...port pressure and operating current Check for insufficient gas Large operating noise and vibrations Check the installation condition Check to make sure that the required spaces for installation specified in the Technical Guide etc are provided 10 Service Diagnosis Service diagnosis 16 10 2 Parameter of primary electronic appliance Picture Parameter Name NO 1 Rated voltage 208 230V 2 Compressor Rat...

Page 19: ...e sensor failure Method of The temperatures detected by the thermistors are used to determine thermistor errors Malfunction Detection Malfunction when the thermistor input is more than 4 92V or less than 0 08V during compressor n o i t a r e p o n o i s i c e D Conditions Note The values vary slightly in some models Supposed Ŷ Faulty connector connection Causes Ŷ Faulty thermistor Ŷ Faulty PCB Tro...

Page 20: ... to turn off power switch before connect or disconnect connector or parts damage may be occurred 10 3 3 Indoor AC fan motor malfunction Indoor Display E14 Method of The rotation speed detected by the Hall IC during fan motor operation is used to determine Malfunction abnormal fan motor operation Detection Malfunction when the detected rotation feedback signal don t received in 2 minutes Decision C...

Page 21: ...5 on the indoor PCB the voltage is about 90 220vac check whether motor can run when turn on the unit the indoor motor is damaged and need replace Yes Measure whether there is voltage pulse 0 5VDC between the positions middle wire and black wire of Terminal CN2 on the indoor PCB the indoor pcb is damaged and need replace Pull out the terminals on the indoor mainboard and reinsert them Is it ok ...

Page 22: ... 25 18ć 5423 5273 8647 8153 7394 7005 6771 5062 27 19ć 5574 5373 8812 8400 7628 7238 6927 5182 30 22ć 5925 5875 9470 9059 8328 8017 7783 5845 32 23ć 5976 5925 9635 9223 8484 8095 7861 5905 32 24ć 6076 6026 9800 9388 8639 8250 8017 6026 outdoor temp humidity 46 cooling value temerature table performance curves 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 cooling capacity W cooling capac...

Page 23: ...356 1697 25 18ć 1105 1118 2781 3005 3117 3292 3452 1760 27 19ć 1158 1138 2845 3069 3164 3324 3516 1776 30 22ć 1172 1185 2957 3196 3308 3548 3708 1901 32 23ć 1192 1165 2989 3292 3356 3612 3756 2121 32 24ć 1212 1145 3037 3356 3404 3676 3804 2279 outdoor temp humidity 46 power consumption value temp table performance curves 100 600 1100 1600 2100 2600 3100 3600 4100 power consumption w indoor tempe D...

Page 24: ...7 6ć 8499 7917 7179 15ć 6954 6597 5615 20ć 6394 6171 5136 25ć 6596 6384 5287 indoor temp humidity 46 heating capacity and indoor outdoor temp table performance curves 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 heating capacity W heating capacity and indoor outdoor temp curves 15ć 20ć 25ć outdoor temp DB WD 22 ...

Page 25: ...655 2923 3192 15ć 1524 1670 1816 20ć 1123 1171 1271 25ć 1129 1182 1277 indoor temp humidity 46 power consumption value temp table performance curves 0 200 400 600 800 1000 1200 1400 1600 1800 2000 15ć 5ć 5ć 7 6ć 15ć 20ć 25ć cooling capacity w outdoor tempe DB WB heating capacity and indoor outdoor temp curves 15ć 20ć 25ć 23 ...

Page 26: ...02 6616 25ć 8280 8366 8536 30ć 8280 8451 8536 35ć 8366 8536 8793 40ć 8451 8878 8878 45ć 6528 6528 6779 performance curves cooling discharge pressure table indoor temp 1500 2000 2500 3000 3500 4000 15ć 25ć 30ć 35ć 40ć 45ć DISCHARGE PRESSURE Outdoor Temp COOLING DISCHARGE PRESSURE 16ć 19ć 22ć ...

Page 27: ...277 2353 25ć 2945 2975 3036 30ć 2945 3005 3036 35ć 2975 3036 3127 40ć 3005 3157 3157 45ć 2321 2321 2411 performance curves cooling suction pressure table indoor temp 350 850 1350 1850 2350 2850 3350 15ć 25ć 30ć 35ć 40ć 45ć SUCTION PRESSURE Outdoor Temp COOLING SUCTION PRESSURE 16ć 19ć 22ć ...

Page 28: ... 5ć 7530 7727 7964 0ć 7648 7806 8043 5ć 7806 7885 8122 10ć 7553 7779 7892 15ć 6333 6521 6584 20ć 6067 6185 6243 performance curves Heating discharge pressure table indoor temp 1000 1500 2000 2500 3000 3500 4000 15ć 10ć 5ć 0ć 5ć 10ć 15ć 20ć DISCHARGE PRESSURE Outdoor Temp HEATING DISCHARGE PRESSURE 15ć 20ć 25ć 26 ...

Page 29: ...04 2888 10ć 2686 2766 2807 15ć 2252 2319 2341 20ć 2157 2199 2220 performance curves heating discharge pressure table indoor temp 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 15ć 10ć 5ć 0ć 5ć 10ć 15ć 20ć SUCTION PRESSURE Outdoor Temp HEATING SUCTION PRESSURE 15ć 20ć 25ć 27 ...

Page 30: ...2015 Johnson Controls Inc www johnsoncontrols com Doc No MH9FYHAH 151103 24 ...

Reviews: