105
FORM 150.63-NM8 (1020)
3
SYS 1
COMP 1
SYS 1
COMP 1
TB7-2
SYS 1
COMP 2
TB7-4
SYS 1
COMP 3
TB7-5
TB7-3
LLSV 1
TB7
SYS 2
HGSV
TB10-7
SYS 2 FAN 2
LOW AMBIENT
SYS 2
FAN 2
TB10-8
TB10-9
TB10-10
SYS 2
FAN 4
TB10
TB10
SYS 2
COMPR 1 (4)
TB10-2
LLSV 2
TB10-3
SYS 2
COMPR 2 (5)
TB10-4
SYS 2
COMPR 3 (6)
TB10-5
TB7
SYS 1
HGSV
TB7-7
SYS 1
FAN 3
TB7-9
SYS 1
FAN 1 LOW
AMBIENT
TB7-10
TB7-8
SYS 1
FAN 1
SYS 1
COMP 2
SYS 1
COMP 3
LLSV 1
SYS 2
HGSV
SYS 2 FANS
2 & 4
SYS 2
FAN 8
SYS 2
FAN 6
SYS 2
COMPR 1 (4)
LLSV 2
SYS 2
COMPR 2 (5)
SYS 2
COMPR 2 (6)
SYS 1
HGSV
SYS 1
FAN 5
SYS 1
FANS 1 & 3
SYS 1
FAN 7
YCUL 0016-0090
YCUL0096-0130
Chiller I/O BOARD
TB2
TXD
DSR
GND
2 RD
5 CTS
7 SG
Printer
Do not connect
shield at printer end
Shield (connect shield to Pin 5
of the connector)
LD03843A
The micro panel is capable of supplying a printout of
chiller conditions or fault shutdown information at any
given time. This allows operator and service personnel
to obtain data and system status with the touch of the
keypad. In addition to manual print selection, the micro
panel will provide an automatic printout whenever a
fault occurs. Detailed explanation of the print function
is given under “Print Key” located in the Keypad and
Display section.
Johnson Controls recommends the field tested WEIGH-
TRONIX model 1220 printer (or former IMP 24). This
is a compact low cost printer that is ideal for service
work and data logging.
The WEIGH-TRONIX printer can be obtained by con
-
tacting WEIGH-TRONIX for purchase information at:
WEIGH-TRONIX
2320 Airport Blvd.
Santa Rosa, CA 95402
Phone: 1-800-982-6622 or 1-707-527-5555
(International
Orders
Only)
The part number for the printer that is packaged specifi
-
cally for YORK is P/N 950915576. The cable to connect
the printer can either be locally assembled from the parts
listed, or ordered directly from WEIGH-TRONIX under
part number 287-040018.
PARTS
The following parts are required:
1. WEIGH-TRONIX model 1220 printer.
2. 2.25" (5.7cm) wide desk top calculator paper.
3. 25 ft. (7.62m) maximum length of Twisted Pair
Shielded Cable (minimum 3 conductor), #18 AWG
stranded, 300V minimum insulation.
4. One 25 pin Cannon connector and shell.
Connector: Cannon P/N DB-25P or equivalent.
Shell: Cannon P/N DB-C2-J9.
ASSEMBLY AND WIRING
All components should be assembled and wired as
shown in Figure 17. Strip the outside insulation back
several inches and individual wires about 3/8" (9.5 mm)
to connect the cable at the I/O Board. Do not connect
the shield at the printer-end of the cable.
Obtaining a Printout
A printout is obtained by pressing the “PRINT” key on
the keypad and then pressing either the “OPER DATA”
key or “HISTORY” key.
FIG. 17 –
PRINTER TO I/O BOARD ELECTRICAL CONNECTIONS
OPTIONAL PRINTER INSTALLATION
Summary of Contents for YCUL0045E
Page 8: ...JOHNSON CONTROLS 8 FORM 150 63 NM8 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 113: ...JOHNSON CONTROLS 113 FORM 150 63 NM8 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 115: ...JOHNSON CONTROLS 115 FORM 150 63 NM8 1020 4...
Page 119: ...JOHNSON CONTROLS 119 FORM 150 63 NM8 1020 4...
Page 121: ...JOHNSON CONTROLS 121 FORM 150 63 NM8 1020 4...
Page 125: ...JOHNSON CONTROLS 125 FORM 150 63 NM8 1020 4...
Page 127: ...JOHNSON CONTROLS 127 FORM 150 63 NM8 1020 4...
Page 129: ...JOHNSON CONTROLS 129 FORM 150 63 NM8 1020 4...
Page 131: ...JOHNSON CONTROLS 131 FORM 150 63 NM8 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 133: ...JOHNSON CONTROLS 133 FORM 150 63 NM8 1020 4...
Page 135: ...JOHNSON CONTROLS 135 FORM 150 63 NM8 1020 4...
Page 137: ...JOHNSON CONTROLS 137 FORM 150 63 NM8 1020 4...
Page 139: ...JOHNSON CONTROLS 139 FORM 150 63 NM8 1020 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 141: ......
Page 142: ...NOTES...
Page 143: ...NOTES...