![background image](http://html1.mh-extra.com/html/york/ycul0026/ycul0026_manual_4221148003.webp)
YORK INTERNATIONAL
3
FORM 150.63-RP5 (903)
UNIT NOMENCLATURE NAME PLATE ENGINEERING DATA
PART NUMBER – LETTER CODES
BASIC PART NUM BER
55
EXTENDED FIELD WARRANTY
X
B
C
D
E
F
G
H
: Aluminum
: Copper
: Black Fin
: Phenolic
: TEAO Fan
Motors
EVAP. FIELD CONDENSER FIELD CABINET FIELD
: 1st Year Parts Only
: 1st Year Parts & Labor
: 2nd Year Parts Only
: 2nd Year Parts & Labor
: 5 Year Compressor Parts Only
: 5 Year Compressor Parts & Labor Only
: 5 Year Units Parts Only
: 5 Year Unit Parts & Labor
: Wire Condenser Headers Only (factory)
: Wire (Full Unit) Enc. Panels (factory)
: Wire/Louvered Enc. Panels (factory)
: Louvered (Cond. Only) Enc. Panels (factory)
: Louvered (Full Unit) Enc. Panels (factory)
: Acoustic Sound Blanket
: Low Sound Fans
: 1" De
fl
ection
: Seismic
: Neoprene Pads
61
PLANT OF MANUFACTURE
R
: Monterrey
56
REFRIGERANT WARRANTY
X
1
2
5
: No Refrigerant Warranty
: 1 Year Refrigerant
: 2 Year Refrigerant
: 5 Year Refrigerant
NOTES:
1. Q :DENOTES SPECIAL / S.Q.
2. # :DENOTES STANDARD
3. X :w/in OPTIONS FIELD, DENOTES NO OPTION SELECTED
4. Agency Files (i.e. U.L. / ETL; CE; ARI; ETC.) will contain info. based on the
fi
rst 14 characters only.
5. Plant of manufacture to include PIN 56 upon entering the chiller order.
38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
X X X
C 1
X B 3
X P 5
X 7
X B
L
A 1
X X S
N
MP
= Multiple Point
SP
= Single Point
NF
= Non-Fused
TB
= Terminal Block
Ser.
= Service
Ind. Sys. Brkr. & L. Ext. Handles
= Individual
System Breaker & Lockable External Handle
: Low Ambient Kit
: High Ambient Kit
: High and Low Ambient Kits
: BAS/EMS Temp. Reset / Offset
: Spanish LCD & Keypad Display
: French LCD & Keypad Display
: German LCD & Keypad Display
: Italian LCD & Keypad Display
: Discharge Pressure Readout
: Suction Pressure Readout
: Discharge and Suction Pressure Readouts
: N. American Safety Code (cU.L./cETL)
: No Listing (typically 50 HZ non-CE, non-U.L.)
: Suction Temp Sensor
: Motor Current Module
: Remote Control Panel
: OptiView Remote Panel
: No Sequence Control
:Low Temp. Brine (LBrT)
:Thermal Storage
:Chicago Relief Code
:Service Isolation Valve
:Both Chicago & Isolat.
:Standard Valve
:Hot Gas By-Pass
(# circuits)
:Heater (Standard)
: Standard Power Option
: MP NF Disc Switches
: MP Circuit Breakers
: SP NF Disc Switch
: SP Terminal Block
: SP Circuit Breaker
: SP TB w/ Ind Sys Brkr
: SP NF Disc Sw w/ Ind Sys Brkr
: Transformer 115/24V (factory)
: Power Factor Capacitor
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
POWER FIELD CONTROLS FIELD COMPRESSOR / PIPING FIELD
X X L # #
M D H
M B A C
S D T S
S X S B
B X F X
S B G 1
D B I
T R
C S X
B
L
N
T
C
R
O
X
: YORK
: Chiller
: Air Cooled
: Scroll
YCUL
0086
EC
46
XCA
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
BASE PRODUCT TYPE NOMINAL CAPACITY UNIT DESIGNATOR REFRIGERANT VOLTAGE/STARTER DESIGN/DEVELOPMENT LEVEL
Y # # # # E C 1 7 C
C B 2 8
U 4 0 A
L 4 6
5 0
5 8
X
High Ef
fi
ciency
:R-22
:R-407C
:200/3/60
:230/3/60
:380/3/60
:460/3/60
:380-415/3/50
:575/3/60
:Across the Line
:Design Series C
:Engineering
Change
or PIN Level
Tons/Kw
0016 0056
0026 0060
0030 0066
0036 0076
0040 0080
0046 0086
0050 0090
: ASME Pressure Vessel