background image

036-21121-002 Rev. A (0602)

Unitary Products Group

19

MATCHING INDOOR COMPONENTS

G1UA
1/2 CASED
UPFLOW

G1HD
HORIZONTAL DUCT

G2FD*
MULTI-POSITION
(UPFLOW, HORIZONTAL
AND DOWNFLOW)

* Available with factory installed horizontal drain pan.

ADD-ON COILS - FOR FURNACE APPLICATIONS

G1NA
UNCASED
UPFLOW

G1FA
FULL CASED
UPFLOW

G2FD090 is upflow only.

AIR HANDLERS -

FOR NON-FURNACE APPLICATIONS

N1AH OR N1VS
MODULAR BLOWER
(UPFLOW, HORIZONTAL
AND DOWNFLOW)

F2RC / F2FC OR
F2RC / F2FP
FAN COIL UNITS
(UPFLOW, HORIZONTAL)

G2FD
COIL

LIGHT COMMERCIAL
APPLICATIONS

Summary of Contents for THRU H*RA018 THRU 060

Page 1: ...re and temperature This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating condi tions occur A...

Page 2: ...3 6 3 11 3 14 3 15 5 4 7 5 6 2 Charge Per Foot Oz 4 0 66 0 66 0 68 0 68 0 68 0 70 070 Operating Weight Lbs 118 123 135 137 161 176 188 Physical and Electrical Data 3 Phase MODEL H1RA 036S25 H1RA 042S...

Page 3: ...8 10 15 18 1000 28 4 21 0 10 00 9 50 F2RP F2FP036 5 8 10 15 19 21 1000 28 0 20 0 10 00 9 00 H2RA036S06 F2RC F2FC036 5 8 10 15 21 1200 33 6 21 5 10 00 9 10 F2RP F2FP036 5 8 10 15 19 21 1200 34 4 25 2...

Page 4: ...24 4 18 5 10 50 9 55 17 G2FD030S17 850 25 0 18 5 10 60 9 65 14 G2FD035S14 850 25 0 18 9 10 60 9 65 17 G2FD036S17 850 25 6 18 9 10 70 9 70 H2RA030S06 875 1125 14 G1FA030S14 1000 28 0 20 7 10 00 9 30 1...

Page 5: ...9 5 29 2 10 00 9 00 17 G2FD046S17 1380 40 0 29 6 10 00 9 05 21 24 G2FD048S21 24 1450 41 0 30 3 10 10 9 15 H1RA048S06 1400 1800 17 G1FA048S17 1500 44 5 33 5 10 00 9 15 21 24 G1FA048S21 24 1600 45 5 33...

Page 6: ...7 4 32 56 9 5 38 50 2 5 61 H2RA030S06 35 61 5 25 1 2 68 20 3 2 97 17 0 3 17 H1RA060S 25 46 35 61 5 54 4 4 46 50 5 4 74 46 3 5 08 40 68 5 27 4 2 70 23 1 3 04 19 7 3 30 40 68 5 60 1 4 44 56 0 4 83 51 6...

Page 7: ...ase for 1H 1C 1H 1C manual change over electronic non programmable thermostat 1H 1C auto manual changeover electronic programmable deluxe 7 day thermostat 1H 1C auto manual changeover electronic progr...

Page 8: ...ER TERMINAL BLOCK ROOM THERMOSTAT CONDENSING UNIT ALL OUTDOOR WIRING MUST BE WEATHERPROOF USE COPPER CONDUCTORS ONLY TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT ALL FIELD WIRING TO BE IN ACCORDAN...

Page 9: ...13 3 12 8 14 5 14 1 13 6 K W 1 97 1 91 1 90 2 02 1 96 1 95 2 05 2 00 1 99 105 T C 18 4 16 6 14 2 18 9 17 1 15 0 19 2 17 4 15 4 S C 12 5 11 8 10 7 13 6 12 8 12 0 14 4 13 7 12 8 K W 1 82 1 77 1 75 1 88...

Page 10: ...4 19 5 18 3 24 8 21 6 20 9 18 6 23 8 22 8 21 1 17 9 S C 16 8 16 8 15 3 16 9 17 9 16 9 17 3 17 9 17 6 18 4 17 6 17 5 K W 2 52 2 37 2 15 2 14 2 54 2 30 2 29 2 17 2 43 2 43 2 30 2 07 115 T C 22 0 19 9 17...

Page 11: ...3 16 3 10 2 99 105 T C 29 3 26 7 24 6 22 0 29 5 27 0 25 0 22 4 29 7 27 2 25 2 23 1 S C 19 9 19 9 19 2 20 0 21 0 21 0 20 1 21 1 22 1 22 1 21 1 22 2 K W 3 27 3 17 3 09 2 98 3 37 3 27 3 19 3 07 3 45 3 37...

Page 12: ...20 7 24 8 23 7 21 6 K W 4 22 4 06 3 90 4 29 4 13 3 94 4 33 4 18 4 00 125 T C 28 7 24 8 20 2 28 9 25 6 21 1 29 0 25 7 21 0 S C 22 5 20 2 18 4 23 2 21 6 19 6 24 2 22 7 20 2 K W 4 47 4 28 4 09 4 56 4 35...

Page 13: ...34 2 29 6 S C 26 8 25 1 23 3 29 0 27 2 25 4 31 1 29 4 27 4 K W 4 81 4 62 4 45 4 96 4 78 4 62 5 10 4 95 4 79 125 T C 33 7 28 4 24 5 35 1 29 4 25 0 36 4 30 4 25 4 S C 25 5 23 5 21 5 28 0 25 7 23 5 30 5...

Page 14: ...45 6 41 6 38 4 34 3 46 0 42 2 39 0 35 0 46 2 42 5 39 3 36 2 S C 30 5 30 6 29 5 30 9 32 6 32 8 31 5 32 8 34 1 34 2 32 7 34 5 K W 5 18 4 96 4 76 4 54 5 30 5 07 4 88 4 67 5 39 5 18 4 99 4 83 115 T C 41 8...

Page 15: ...7 50 3 S C 45 7 43 5 40 8 42 4 40 2 38 0 39 2 37 0 35 2 K W 6 19 6 10 6 00 6 09 5 99 5 87 5 98 5 88 5 74 105 T C 57 2 53 4 48 4 56 6 52 3 47 4 56 0 51 1 46 4 S C 44 6 42 1 39 3 41 3 39 0 36 6 38 0 35...

Page 16: ...5 08 5 27 5 14 5 10 5 28 5 15 5 11 95 T C 60 0 57 4 53 7 60 7 58 5 54 8 61 4 59 0 55 8 S C 37 5 37 1 35 9 40 3 39 8 38 8 43 1 42 6 41 6 K W 5 86 5 70 5 65 5 87 5 71 5 67 5 88 5 72 5 68 105 T C 58 1 5...

Page 17: ...60 3 K W 6 53 6 42 6 37 6 86 6 74 6 70 7 18 7 07 7 04 95 T C 73 8 71 1 67 2 76 1 73 5 69 9 78 4 75 9 72 6 S C 47 1 46 7 45 4 54 0 53 6 52 4 60 9 60 4 59 4 K W 7 08 6 94 6 90 7 43 7 30 7 26 7 79 7 65 7...

Page 18: ...8 97 8 86 8 75 9 01 8 90 8 79 9 04 8 94 8 84 95 T C 94 0 87 7 81 5 95 8 89 0 82 1 97 5 90 1 82 7 S C 68 6 63 8 59 0 69 3 64 0 58 7 70 0 64 2 58 5 K W 9 64 9 50 9 37 9 68 9 55 9 41 9 72 9 59 9 45 105...

Page 19: ...DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATIONS G1NA UNCASED UPFLOW G1FA FULL CASED UPFLOW G2FD090 is upflow only AIR HANDLERS FOR NON FURNACE APPL...

Page 20: ...e without notice Printed in U S A 036 21121 002 Rev A 0602 Copyright by York International Corp 2002 All rights reserved Supersedes 036 21121 001 Rev A 301 Unitary 5005 Norman Products York OK Group D...