400034-YTG-B-0708
Johnson Controls Unitary Products
7
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(Min.-max.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL
SENS.
TCGD12S21S2(H)
450 - 750
14,17
FC/MC/PC18
450
12.0
9.1
13.00
11.00
450 - 750
14
HC18
450
12.0
9.1
13.00
11.00
450 - 750
14,17
UC18
450
12.0
9.1
13.00
11.00
TCGD18S21S2(H)
450 - 750
14,17
FC/MC/PC18
600
18.0
12.6
13.00
11.00
450 - 750
14,17
FC/MC/PC24
600
18.0
12.6
13.00
11.00
450 - 750
14
HC18
600
18.0
12.6
13.00
11.00
450 - 750
14,17
UC18
600
18.0
12.6
13.00
11.00
450 - 750
14,17
UC24
600
18.0
12.6
13.00
11.00
TCGD24S21S2(H)
600 - 1000
14
FC/MC/PC32
800
24.0
17.2
13.00
11.00
600 - 1000
17,21
FC/MC/PC35
800
24.0
17.2
13.00
11.00
600 - 1000
14,17,21
FC/MC/PC36
800
24.0
17.2
13.00
11.00
600 - 1000
14
FC/MC/PC37
800
24.0
17.2
13.00
11.00
600 - 1000
17,21
FC/MC/PC43
800
24.0
17.2
13.00
11.00
600 - 1000
14
HC30
800
24.0
17.2
13.00
11.00
600 - 1000
17
HC36
800
24.0
17.2
13.00
11.00
600 - 1000
21
HC42
800
24.0
17.2
13.00
11.00
600 - 1000
14,17,21
UC36
800
24.0
17.2
13.00
11.00
TCGD30S21S2(H)
800 - 1200
14
FC/MC/PC32
1000
29.0
21.2
13.00
11.00
800 - 1200
17,21
FC/MC/PC35
1000
29.0
21.2
13.00
11.00
800 - 1200
14
FC/MC/PC37
1000
29.0
21.2
13.00
11.00
800 - 1200
17,21
FC/MC/PC43
1000
29.0
21.2
13.00
11.00
800 - 1200
17
HC36
1000
29.0
21.2
13.00
11.00
800 - 1200
21
HC42
1000
29.0
21.2
13.00
11.00
TCGD36S21S2(H)
1000 - 1400
14
FC/MC/PC37
1200
35.0
24.4
13.00
11.00
1000 - 1400
17,21
FC/MC/PC43
1200
35.0
24.4
13.00
11.00
1000 - 1400
21,24
FC/MC/PC48
1200
35.0
24.4
13.00
11.00
1000 - 1400
21
HC42
1200
35.0
24.4
13.00
11.00
1000 - 1400
21,24
UC48
1200
35.0
24.4
13.00
11.00
TCGD42S21S2(H)
1200 - 1600
17,21
FC/MC/PC43
1400
42.0
29.4
13.00
11.00
1200 - 1600
21,24
FC/MC/PC48
1400
42.0
29.4
13.00
11.00
1200 - 1600
21
HC42
1400
42.0
29.4
13.00
11.00
1200 - 1600
21,24
UC48
1400
42.0
29.4
13.00
11.00
TCGD48S21S2(H)
1400 - 1800
21,24
FC/MC/PC48
1550
46.0
32.6
13.00
11.00
1400 - 1800
21,24
UC48
1550
46.0
32.6
13.00
11.00
TCGD60S21S2
1600 - 2000
24
FC/MC62
2000
55.0
41.0
13.00
11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.