FIGURE 4 - UNIT DIMENSIONS & CLEARANCES 15, 20 & 25 TON
RETURN
AIR
SUPPLY
AIR
BOTTOM SUPPLY
AND RETURN
AIR OPENINGS
(See Note)
(B)
POWER WIRING
ENTRY
(A)
CONTROL WIRING
ENTRY
NOTE:
For curb mounted units, refer to the curb hanger
dimensions of the curb for the proper size of the
supply and return air duct connections.
UNIT BASE WITH RAILS
Shown separately to illustrate
Bottom Duct openings and Power
Connection locations
12-1/2"
9-1/4"
8-1/8"
9-3/4"
3-3/4"
(B)
POWER WIRING
ENTRY
(A)
CONTROL WIRING
ENTRY
92"
CONDENSER
COILS
OPTIONAL COIL
GUARD KIT
COMPRESSOR
ACCESS
(See detail "X")
ECONOMIZER / MOTORIZED DAMPER,
FIXED OUTDOOR INTAKE AIR AND
POWER EXHAUST RAIN HOODS
(See detail "Y")
FIELD-SUPPLIED
DISCONNECT SWITCH
LOCATION
BLOWER
ACCESS
BLOWER MOTOR
ACCESS
BLOWER
COMPARTMENT
ACCESS
(Auxiliary)
DOT PLUG
(For pressure
Drop Reading)
FRONT
VIEW
ELECTRIC HEAT
ACCESS
CONTROL BOX
ACCESS
21"
5"
9-3/4"
11-1/2"
2-3/4"
21-1/2"
33"
35"
5-7/8"
RETURN AIR
SUPPLY AIR
OUTDOOR AIR
OUTDOOR AIR
(Economizer)
24-1/4" (15 TON)
36-1/4" (20, 25 TON)
48-5/8" (15TON)
52-5/8" (20, 25 TON)
125-1/4" (15 TON)
136-1/4" (20, 25 TON)
HOLE
OPEN ING
SIZE
(DIA.)
USED FOR
A
1-1/8" KO
Con trol
Wir ing
Front
3/4" NPS (Fem.)
Bot tom
B
3-5/8" KO
Power
Wir ing
Front
3" NPS (Fem.)
Bot tom
C
2-3/8" KO
Gas Piping (Front)
1
D
1-11/16" Hole
Gas Piping (Bot -
tom)
1,2
1
1" piping MPT required.
Opening in the bot tom of the unit can be located by the slice
in the insula tion.
UTILITIES ENTRY DATA
All dimensions are in inches. They are
subject to change without notice. Certified
dimensions will be provided upon request.
2
RETURN
AIR
SUPPLY
AIR
BOTTOM SUPPLY
AND RETURN
AIR OPENINGS
(See Note)
(B)
POWER WIRING
ENTRY
(A)
CONTROL WIRING
ENTRY
NOTE:
For curb mounted units, refer to the curb hanger
dimensions of the curb for the proper size of the
supply and return air duct connections.
UNIT BASE WITH RAILS
Shown separately to illustrate
Bottom Duct openings, Power
and Gas Piping Connection
locations
12-1/2"
9-1/4"
8-1/8"
9-3/4"
3-3/4"
(B)
POWER WIRING
ENTRY
(A)
CONTROL WIRING
ENTRY
92"
CONDENSER
COILS
OPTIONAL
COIL GUARD
KIT
COMPRESSOR
ACCESS
(See detail "X")
ECONOMIZER / MOTORIZED DAMPER,
FIXED OUTDOOR INTAKE AIR AND
POWER EXHAUST RAIN HOODS
(See detail "Y")
FIELD-SUPPLIED
DISCONNECT SWITCH
LOCATION
BLOWER
ACCESS
BLOWER MOTOR
ACCESS
BLOWER
COMPARTMENT
ACCESS
(Auxiliary)
DOT PLUG
(For pressure
Drop Reading)
FRONT
VIEW
CONTROL BOX
ACCESS
21"
5"
9-3/4"
11-1/2"
2-3/4"
21-1/2"
33"
35"
5-7/8"
46-5/8"
7-1/8"
6-3/8"
VENT AIR
OUTLET
HOODS
COMBUSTION
AIR INLET
HOOD
GAS HEAT
ACCESS
(C)
GAS SUPPLY
ENTRY
46-5/8"
11-1/8"
(D)
GAS SUPPLY
ENTRY
12-1/4" (15
TON)
35-1/4" (20, 25
TON)
52-5/8" (20, 25 TON)
RETURN AIR
SUPPLY AIR
OUTDOOR AIR
OUTDOOR AIR
(Economizer)
48-5/8" (15 TON)
125-1/4" (15
TON)
136-1/4" (20, 25
TON)
Front
36"
Back
24" (Less Economizer)
49" (With Economizer)
Left Side (Filter Access)
24" (Less Economizer)
36" (With Economizer)
Right Side (Cond. Coil)
36"
Below Unit
1
2
0"
Above Unit
2
72" With 36" Maximum
Horizontal Overhang
(For Condenser Air
Discharge)
Units (applica ble in U.S.A. only) may be installed on combustible floors
made from wood or class A, B or C roof covering material.
2
Units must be installed outdoors. Overhanging structures or shrubs should
not obstruct condenser air discharge out let.
NOTE:
ELEC/ELEC Mod els: Units and duct work are approved for zero clearance to
combustible materials when equipped with elec tric heat ers.
GAS/ELEC Models: A 1" clearance must be provided between any
combustible material and the supply air duct work for a distance of 3 feet
from the unit.
The products of combustion must not be al lowed to accumulate within a
con fined space and recirculate.
Locate unit so that the vent air outlet hood is at least:
•
Three (3) feet above any forced air inlet located within 10 horizontal feet (ex-
cluding those integral to the unit).
•
Four (4) feet below, 4 horizontal feet from, or 1 foot above any door or grav ity
air inlet into the building.
CLEARANCES