background image

With the Zone Status Screen, the thermostat Icon now unveils all of your zone 

sensors' statuses.

Access the sensor status by pressing the thermostat icon.

Access the Zone Panel Status by pressing the

Accessories Icon.

Touch ICON

 for a detailed view 

Log

Menu

Refresh

Accessories

Exit Service Mode

Humidifier

ON
UV Lamps

ON

EAC

Not Installed

Heat Pump

OFF

Thermostat

ON

Furnace

ON

11:07AM Thu  21  Jul

Back

Log

Refresh

Accessories

Touch ICON for a detailed view 

Status

Humidifier

ON
UV Lamps

ON

EAC

Not Installed

Heat Pump

OFF

Thermostat

ON

Furnace

ON

Log

resh

Accessories

UV La

ON

EAC

Not In

Furna

ON

Select Zone

10:31AM Wed 04  Jan

Back

Refresh

Touch ICON for a detailed view 

Ventilator

ON

Dehumidifier

ON

Back

Refresh

Accessories

Zone Panel 

ON

Zone 5

ON

Zone 6

ON

Because your system is optimized for airflow in every zone, the continuous 

fan must be controlled differently than a non-zoned system.

The fan can be operated in three different modes:

Auto Mode: 

Only runs the fan when the zone

is calling for condition (heating or cooling).

Manual Mode: 

Will circulate air in the zone

when no other zone is calling for conditioning.

NOTE: 

Any percentage setting selected will

be automatically designated to all zones and

override all zone schedules. This is done to

ensure that there are no conflicting airflows at

a given time.

Schedule Mode: 

Runs the fan according to settings as defined in the programmed sched-

ule assigned for the current day part.

5%

100%

OK

Cancel

Master / Fan Adjust

Always

Run Fan 

Auto

Manual

Function:

23%

Show Fan on

Home

The Communicating Zone System allows for custom names to be created and 

displayed on Touch Screen Communicating Controls.

Selecting descriptive names for each zone allows for easier navigation when making

changes or settings from multiple locations in the home.
Access this feature through the menu settings

screen under "Zoning".
Once at the screen, you can view and change

each installed zone name.
Another feature available in the zone settings

screen is "Not Zoned" mode. This setting allows

you to have the system operate according to

the master zone's temperature and set point

while keeping all zone dampers open.

Zone Mode:

Living Room 

 / Zoning Config

Bedroom 1

Not Zoned

Zoned

Edit

Kitchen

Edit

Bedroom 2

Edit

Master Name:

Zone 2 Name:

Zone 3 Name:

Bedroom 3

Edit

Zone 4 Name:

Bedroom 3

Edit

Zone 4 Name:

OK

Cancel

The Communicating Zone System has the ability to control each zone's 

humidity with separate set points. This allows you to customize your comfort 

throughout your home.

When a Touch Screen Communicating Control is

installed in a zone as a sensor, it is constantly

tracking your humidity levels for the installed

zone. 
The Master Touch Screen uses this information to

control equipment and airflow in that zone to the

settings desired. 
Navigate to the humidity settings screen from the

menu or the short cut humidity icon in the zone (or

from the Master Touch Screen) to view or make

changes to this setting.

Schedule

Emergency

Heat

Close

Alert: Change Filter

Status

Humidity

Fan

Settings

Dealer

Tools

Clean

Manage

Zones

Living Room

72°

Menu

Auto

ON

71

°

72°

11:07AM Thu 21 Jul

55°  

Alert: Change Filter

30%

Humidity

In addition to having the ability to run a schedule as assigned per zone, the 

Communicating Zone System can be easily set up to control every zone to 

the same set point for a predetermined amount of time.

Vacation mode is accessed from the Advanced

Programmable View / Mode home screen. Select

the schedule button and press "Set Vacation".
This will bring up the vacation wizard which will

instruct you to set your "Leave" / "Return" date

and time, Temperature set points, Fan settings

and Humidity settings.
The thermostat will control all zones to these set-

tings without requiring setup at any other zone

sensors.

Menu

View Schedule...

Set Vacation...

Day

8:00AM

78° 

66°

Extend NOW or change to...

Return

5:00PM

73° 

61°

10:00PM

Sleep

80° 

57°

6:00AM

Awake

77° 

55°

8:30AM Thu 05 Jan

NOW

OK

Vacation

Days

Leave

Return

2012

Jan

5

2012

Jan

10

AM

10

AM

10

1

For how long?

Next

Cancel

8

8

6

5

Customizing Your Different Zone Names

Zone Status (System Map) Screen

Continuous Fan in a Zoning System 

Whole Home Humidity Control

Vacation Mode for your Zoning System

Reviews: