ENGLISH
7
EN
OUTDOOR UNIT PICTURES
285
290
530
110
62
590
750
RVJC 18
RVJC 07-12
335
125
560.1
141.5
135
351.2
694.5
301.5
843
313
235
PARTS INSTALLATION
NOTES
CAUTIONS
•
Ensure that the space around the left and right of the
indoor unit is more than 12cm.
The indoor unit should be installed allowing a minimum
clearance of 15cm from the ceiling.
•
Use a stud
fi
nder to locate studs to prevent unnecessary
damage to the wall.
•
A minimum pipe run of 3 metres is required to minimise
vibration & excessive noise.
•
The indoor unit should be installed on the wall at a height
of 2.3 metres or more from the
fl
oor.
•
A, B and C directions should be free from obstructions.
NOTES
•
This illustration is for explanation purposes only.
•
Copper lines must be insulated independently.
C
B
A
1
2
3
5
4
7
6
Self-tapping screw B
ST3.9X10
Loop the
connective
cable.
Remote Controller
Air F
ilter
Remote Controller
holder
30cm m
inim
um
200cm
minimu
m
60cm mi
nimum
30cm minimu
m
12cm minimum
12cm mini
mum
15cm m
inimum
60cm minimum
Except the above parts provided, the other parts needed
during installation you must purchase.
Number
Name of part
Q’ty
1
Installation plate
1
2
Clip anchor
8
3
Self-tapping screw A ST3.9X25
8
4
Connecting
pipe
assembly
Liquid side ø 6.35
Parts you
must
purchase
Gas side
ø 9.53 (<12000Btu/h model)
ø 12.7 (
f
12000Btu/h model)
5
Remote controller
1
6
Self-tapping screw B ST3.9X10
2
7
Remote controller holder
1
8
Seal
1
9
Drain joint
1
J355-EN.indd 7
J355-EN.indd 7
1/12/07 3:20:57 PM
1/12/07 3:20:57 PM