1

SET TEMPERATURE

( )

AU TO
COO L

DRY

HE AT

FAN

HIGH

ME D

LO W

MODE

FA N SPEE D

ON/OFF

SWIN G

TIMER ON

       AI R

DIRECTION

TIMER OF F

    LE D
DISPLA Y

RESE T L OC K

TEMP

TIMER ON OF F

2

Set the starting & stopping time

1.  Push the TIMER ON button, the remote controller 

will show TIMER ON, the last set time for START 
operation and the signal “h” will be shown on the 
LCD display area.

  You are now ready to readjust the TIMER ON to 

start the operation.

2. Push the TIMER ON button again to set the time 

you want to start the operation.

3.  Push the TIMER OFF button, the remote controller 

will show TIMER OFF, the last set time for STOP 
operation and the signal “h” will be shown on the 
LCD display area. You are now ready to reset the 
time to STOP operation.

4. Push the TIMER OFF button again to set the time 

you want to stop the operation.

5. After setting the TIMER, there will be a one-half 

second delay before the remote controller transmits 
the signal to the Air Conditioner. Then, after approxi

-

mately another 2 seconds, the set temperature will 
re-appear on the digital display.

Notes:

-  The timer setting (TIMER ON or TIMER OFF) that in sequence occurs directly 

after the actual time will be activated  rst.

-  If the same time is set for both TIMER ON and TIMER OFF settings, the 

TIMER OFF time will automatically increase 0.5h (the set time is less than 
10 hours) or  

1

 hour (the set time is more than 10 hours). If the time settings 

for both TIMER ON and TIMER OFF are 24 hours, the TIMER ON settings 
will automatically decrease 1 hour.

Change the TIMER

To change the TIMER ON/OFF time, just press the corresponding TIMER button 
and reset the time.

8

Timer operation

Summary of Contents for R91 BGE

Page 1: ...AIRCONDITIONER REMOTECONTROLLERILLUSTRATION Thank you very much for purchasing our air conditioner Please read thisowner smanual carefully before using your air conditioner OWNER SMANUAL...

Page 2: ...Automatic operation 5 Cooling Heating Fan only operation 6 Drying operation 6 Timer operation 7 Cautions 9 Performance Features 1 Operating Mode AUTO COOL DRY HEAT and FAN 2 Timer Setting Function in...

Page 3: ...L OCK TEMP Speci cations Featuresof remote controller 1 Model R91 BGE R91 BGCE R91A BGE R91 BGCE Rated Voltage 3 0V Lowest Voltage of CPU Emitting Signal 2 0V Reaching Distance 8m when using 3 0 volta...

Page 4: ...the current settings are cancelled and the control will return to the initial settings Use a 1mm little round stick to push the button TURBO Button Push this button on COOL HEAT mode the air condition...

Page 5: ...lay Displaysthetemperaturesetting 17 Cto30 Cor timer setting 0 24h When you set the operat ing mode to FAN ONLY no temperature setting isdisplayed TIMERdisplay This display area shows the settings of...

Page 6: ...e battery compartment o according to the arrow direction then replace the old batteries with new ones 2 Insertthenewbatteriesmakingsure that the and of battery are installed correctly 3 Reattach the c...

Page 7: ...ting underthesameconditionswhenyousimplypush the ON OFFbutton of the remote controller Start Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the in...

Page 8: ...ature themostcomfortabletemperature is between 21 C to 28 C 3 ON OFF button When the remote controller is o push this buttontostarttheairconditioner Nofanspeed indicator displays The Indoor fan speed...

Page 9: ...ioner Then after approximately another 2 seconds the signal h disappears and the set temperature will re appear on the digital display To set the stopping time 1 Push the TIMER OFF button and the remo...

Page 10: ...reset the time to STOP operation 4 Push the TIMER OFF button again to set the time you want to stop the operation 5 After setting the TIMER there will be a one half seconddelaybeforetheremotecontroll...

Page 11: ...when there is no receiving beep from the indoor unit or if the transmission indicator on the remote controller fails to light 4 Be sure there are no barriers between the remote controller and the rec...

Page 12: ...2008 Johnson Controls Inc www johnsoncontrols com Form NO 035M70011 002 Johnson Controls reserve the right to change product features without prior notice...

Reviews: