PHYSICAL DATA 

NOMINAL TONNAGE

MODELS

PCE6B3631

PCE6B4831

PCE6B6031

3.0

4.0

5.0

AHRI Cooling Performance

Gross Capacity @ AHRI A point (MBH)

36.5

49.1

60.0

AHRI net capacity (MBH)

36.0

45.5

58.0

EER

12.5

12.0

12.0

SEER

16.0

16.0

16.0

Nominal CFM

1200

1600

2000

System power (KW)

3.0

3.6

4.6

Refrigerant type

R410A

R410A

R410A

Refrigerant charge (lb-oz)

11-8

13-8

14-00

Dimensions (inches)

Length

51-1/4

51-1/4

51-1/4

Width

45-3/4

45-3/4

45-3/4

Height

49

53

55

Operating WT. (lbs.)

460

483

500

Compressors

Type

Scroll

Scroll

Scroll

Stages

2

2

2

Condenser Coil Data

Face area (Sq. Ft.)

19.5

23.8

25.9

Rows

2

2

2

Fins per inch

22

22

22

Tube diameter

 3/8

 3/8

 3/8

Circuitry Type

Interlaced

Interlaced

Interlaced

Evaporator Coil Data

Face area (Sq. Ft.)

6.3

6.3

6.3

Rows

3

3

4

Fins per inch

16

16

16

Tube diameter

 3/8

 3/8

 3/8

Circuitry Type

Interlaced

Interlaced

Interlaced

Refrigerant control

TXV

TXV

TXV

Condenser Fan Data

Fan diameter (Inch)

26

26

26

Type

Prop

Prop

Prop

Drive type

Direct

Direct

Direct

No. speeds

1

1

1

Motor HP each

 1/3

 1/3

 1/3

RPM

850

850

850

Nominal total CFM

3200

3200

3200

Direct Drive Evaporator Fan Data

Fan Size (Inch)

11 x 10

11 x 10

11 x 10

Type

Centrifugal

Centrifugal

Centrifugal

Motor HP each

 1/2

 3/4

1

RPM

1200 Max

1200 Max

1200 Max

Frame size

48

48

48

Filters

Filter Size

B

B

B

Quantity - Size

Field-supplied external filters must be sized so as not to exceed 300 fpm air velocity through disposable fil-
ters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for 
replacement filter sizes. A=20 x 20, B=20 x 30

Summary of Contents for PCE6x36 THRU 60 Series

Page 1: ...A and tested prior to shipment Test stations using a state of the art computerized process system are used to insure product quality Refrigerant charge and component part numbers are verified via comp...

Page 2: ...st be set to YES and a humidistat is connected from the low volt age R and HUM color coded leads During cooling operation if the humidity level is above the humidistat set point the indoor blower spee...

Page 3: ...t low Nox 3 Cabinet Size A small 35 x 51 B large 45 x 51 8 Generation Level 1 first generation 4 Nominal Air Conditioning Cooling Capacity BTUx1000 24 24 000 BTU etc 9 Revision Level A original releas...

Page 4: ...duct openings on the roof curb Transition is from rectangle to 16 round for the 1AK0108 kit and from rectangle to 18 round for the 1AK0109 kit Roof Curbs S1 1RC0503 S1 1RC0501 NRCA approved curbs prov...

Page 5: ...eated galvanized steel shall provide a better paint to steel bond which resists corrosion and rust creep Powder paint finish shall provide superior corrosion resistance 1000 hour salt spray tested On...

Page 6: ...to control refrigerant flow CONTROLS Simple Control Circuit Field thermostat wiring connects to color coded leads using twist on wire connections Cooling controls use contactor and relays for simple...

Page 7: ...e Interlaced Interlaced Interlaced Evaporator Coil Data Face area Sq Ft 6 3 6 3 6 3 Rows 3 3 4 Fins per inch 16 16 16 Tube diameter 3 8 3 8 3 8 Circuitry Type Interlaced Interlaced Interlaced Refriger...

Page 8: ...6 18 1 15 4 16 6 11 0 18 7 19 4 17 7 18 5 11 7 K W 4 23 4 22 4 19 4 19 4 13 4 17 4 18 4 18 4 15 4 10 4 11 4 14 4 17 4 12 4 07 COOLING PERFORMANCE DATA 3 TON HIGH SPEED PACKAGED UNIT MODEL NO PCE6B36...

Page 9: ...4 17 5 12 5 20 4 11 4 17 9 17 6 11 8 22 3 12 1 K W 3 98 4 10 3 98 3 91 3 89 3 99 4 05 4 00 3 92 3 93 4 00 4 01 4 02 3 93 3 97 COOLING PERFORMANCE DATA 4 TON HIGH SPEED PACKAGED UNIT MODEL NO PCE6B48...

Page 10: ...24 3 27 5 24 6 25 9 18 4 25 1 26 7 25 2 27 5 19 6 K W 4 57 4 38 4 39 4 35 4 32 4 58 4 47 4 49 4 46 4 43 4 58 4 57 4 59 4 56 4 54 COOLING PERFORMANCE DATA 5 TON HIGH SPEED PACKAGED UNIT MODEL NO PCE6B...

Page 11: ...f duct 2 Units must be installed outdoors Overhanging structures or shrubs should not obscure outdoor air discharge outlet 3 Units may be installed on combustible floors made from wood or class A B or...

Page 12: ...Breakers for heaters are included in the 20kW and 25kW heater kits 1 MCA Minimum Circuit Ampacity 2 Maximum Over Current Protection per standard UL 1995 3 Fuse or HACR circuit breaker to be field ins...

Page 13: ...9 0 45 69 0 NOTES Single source power MCA and MOP requirements are given here for reference if the unit is to be installed with a field installed single point power modification Breakers for heaters a...

Page 14: ...nt Wiring Kit Unit Fuse Size A Heater Fuse Size A PCE6B3631 230 3 60 6HK06501025 S1 2SPWK031 30 30 6HK06501525 S1 2SPWK033 30 45 PCE6B4831 230 3 60 6HK06501025 S1 2SPWK032 35 30 6HK06501525 S1 2SPWK03...

Page 15: ...635 582 523 459 Low Cool A 1153 1095 1036 979 899 810 751 697 643 588 B 1015 952 884 802 709 646 582 528 467 402 C 882 805 741 625 556 501 415 359 297 228 D 805 718 642 523 436 376 294 247 193 118 El...

Page 16: ...0 16 1300 0 07 0 03 0 17 1400 0 08 0 04 0 18 48 4 0 1100 0 02 0 02 0 04 1200 0 03 0 02 0 04 1300 0 04 0 02 0 05 1400 0 05 0 03 0 05 1500 0 06 0 04 0 06 1600 0 07 0 04 0 07 1700 0 07 0 04 0 08 1800 0...

Page 17: ...OF CURB INSTALLATION REAR DUCT ROOF CURB INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION A0324 001 UNIT TYPICAL SLAB ON GROUND INSTALLATION A0390 001 SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DU...

Page 18: ...Inc All rights reserved Supersedes 5291656 YTG D 0817 York International Corp 5005 York Drive Norman OK 73069 UNIT TYPICAL ROOF CURB INSTALLATION SUPPLY AIR DUCT TO POWER SUPPLY RETURN AIR DUCT FIELD...

Reviews: