background image

TECHNICAL GUIDE 

MODELS: MV

MODULAR VARIABLE SPEED AIR HANDLERS
FOR USE WITH SPLIT SYSTEM 
COOLING & HEAT PUMP

1200 - 2000 CFM BLOWERS

3 - 5 TON COILS
OPTIONAL 1 & 3

φ

 ELECTRIC HEATERS

Due to continuous product improvement, specifications 
subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at 
www.ari.org/aridirectory

ISO 9001

Certified Quality

Management System

255427-YTG-F-1006

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

DESCRIPTION

This unique modular system allows the flexibility to handle any
application. These versatile coils and blowers may be used for
upflow, downflow, or horizontal left or right applications. They
may be combined to function as a cooling only unit or with a heat
pump including electric heat for 1 and 3 phase applications. The
blower and electric heater could be used as stand alone electric
furnaces.

FEATURES

BLOWERS - Models to match any air flow or voltage require-
ment. The compact size allows easy installation. Blowers are
sized to deliver design air quantity both efficiently and quietly.
The motors provide a selection of air quantities to match any
application. All models include a one-minute blower off delay as
standard to enhance system efficiency ratings. The durable, pre-
painted steel protects the unit against rust and corrosion. All
models have 1 inch foil face fiber glass insulation, providing a
thermal insulation value of R-4.2. 

COILS - Staggered rows of rifled copper tubes are mechanically
expanded into enhanced surface aluminum fins to provide high
heat transfer and long-lasting quality. The MC multi-position
coils may be used for upflow, downflow, and horizontal left or
right applications. Coil cabinets are insulated with 3/4" foil face
insulation to prevent sweating.

ELECTRIC HEATERS - Both single and three phase electric
heater models are available to match any requirement. All heat-
ers include nickel-chromium elements with a 5-year limited war-
ranty on 1 Ø heating elements and 1 year limited warranty on 3
Ø heating elements. Sequential operation is provided to control
heaters in all models. Circuit breakers are used in 208/230 volt,
single-phase heaters of 15 KW and larger.

Models equipped with circuit breakers may be altered in the field 
to use multi-source power supply. Over-temperature limit 
switches provide protection from airflow loss with fusible link 
backup protection.

ACCESSORIES - A full line of matching accessories available
for use with the blower and coils to allow any type application.

LIMITATIONS - These units must be wired and installed in 
accordance with all national and local safety codes.

Voltage limits are as follows:

AIR HANDLER VOLTAGE

NORMAL OPERATING 

VOLTAGE RANGE*

208/230-1-60

187 - 253

* Rated in accordance with ARI Standard 110, utilization range “A”.
Air flow must be within the minimum and maximum limits approved for electric
heat, evaporator coils and outdoor units.

Summary of Contents for MC18A2AH1

Page 1: ... 1 inch foil face fiber glass insulation providing a thermal insulation value of R 4 2 COILS Staggered rows of rifled copper tubes are mechanically expanded into enhanced surface aluminum fins to provide high heat transfer and long lasting quality The MC multi position coils may be used for upflow downflow and horizontal left or right applications Coil cabinets are insulated with 3 4 foil face ins...

Page 2: ...Depending on combination 16 1 2 14 19 32 7 8 1 2 1 3 8 1 1 23 32 1 1 4 7 8 1 2 MV12D 25 24 1 2 23 1 2 21 19 32 MV16C 25 21 20 18 3 32 MV20D 25 24 1 2 23 1 2 21 19 32 MC24B H 26 1 2 17 1 2 16 1 2 16 3 8 3 8 3 4 MC30B H 26 1 2 17 1 2 16 1 2 16 3 8 MC35B H 22 17 1 2 16 1 2 16 3 8 MC35C H 26 1 2 21 20 19 7 8 MC36B H 26 1 2 17 1 2 16 1 2 16 3 8 7 8 MC36C H 26 1 2 21 20 19 7 8 MC42B H 32 17 1 2 16 1 2 1...

Page 3: ...C60D H 1275 85 72 53 7 48 4 43 5 37 5 80 67 43 0 38 0 33 3 27 7 75 62 33 1 28 1 24 5 22 4 70 57 28 8 26 5 24 5 22 4 MC61D H 1450 85 72 91 7 78 4 68 1 52 3 80 67 73 4 61 5 52 0 38 6 75 62 57 3 45 6 38 4 31 2 70 57 49 2 43 0 38 4 31 2 MV16C MC42C H 1400 85 72 88 4 76 0 63 3 50 0 80 67 70 8 59 4 48 4 37 0 75 62 55 2 43 9 35 8 29 9 70 57 47 4 41 5 35 8 29 9 MC48C H 1650 85 72 100 5 86 4 72 0 56 8 80 6...

Page 4: ... Pump Sweat 3 40 2 14 2 14 x 17 5 1 x 0 866 3 8 Enhanced None 53 MC18A2AH1 2A MC18B3XH1 3 40 2 14 2 14 x 17 5 None 53 MC18B2AH1 2A MC24A3XH1 4 38 2 14 2 18 x 17 5 None 56 MC24A2AH1 2A MC24B3XH1 4 38 2 14 2 18 x 17 5 None 56 MC24B2AH1 2A MC30A3XH1 4 38 2 14 2 18 x 17 5 None 56 MC30A2AH1 2A MC30B3XH1 4 38 2 14 2 18 x 17 5 None 56 MC30B2AH1 2A MC35B3XH1 3 90 3 12 2 16 x 17 5 None 65 MC35C3XH1 None MC...

Page 5: ...7 6 45 1 60 1 3 3 4 4 6 6 8 8 13 2 17 6 4HK16502006 0 5 Heat D 14 4 19 2 49 2 65 5 3 6 4 8 7 2 9 6 14 4 19 2 MV20D 4HK 6501006 0 5 Heat D 7 2 9 6 24 6 32 8 3 6 4 8 7 2 9 6 7 2 9 6 4HK16501506 0 5 Heat D 10 8 14 4 36 9 49 1 3 6 4 8 7 2 9 6 10 8 14 4 4HK16501806 0 5 Heat D 13 2 17 6 45 1 60 1 3 3 4 4 6 6 8 8 13 2 17 6 4HK16502006 0 5 Heat D 14 4 19 2 49 2 65 5 3 6 4 8 7 2 9 6 14 4 19 2 4HK16502506 0...

Page 6: ...8 133 75 125 150 1 1 0 1 30 KW 3 phase not approved for single source power supply 2 OCP Over Current Protection device must be HACR type Circuit Breaker or Time Delay fuse May be 0 no breaker or 1 with breaker ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY COPPER WIRE 208 230 3 60 Models Heat Kit Three Phase Heater Amps 240V Field Wiring Min Circuit Ampacity Max O C P 1 Amps Type 75 C Wire Size A...

Page 7: ...lay fuse KW MBH CONVERSIONS FOR 208 VOLT OPERATION MULTIPLY 240 VOLT TABULATED KW MBH BY 751 230 VOLT 240 VOLT 918 ELECTRICAL DATA COOLING UNIT ONLY 60 Hz MODEL Total Motor Amps Minimum Circuit Ampacity Max O C P 1 Amps Type Minimum Wire Size AWG 75 C 60 Hertz 60 Hertz 208V 230V 208V 230V MV12B 4 7 4 3 5 9 5 4 15 14 MV12D 4 7 4 3 5 9 5 4 15 14 MV16C 6 1 5 0 7 6 6 9 15 14 MV20D 7 8 7 0 9 7 8 8 15 1...

Page 8: ...If an electric heat accessory which is rated for greater than zero clearance to combustible surfaces is installed in these air handlers in the downflow operating positions on a combustible floor one of the follow ing combustible floor base accessories is required 1FB1817 1FB1821 or 1FB1824 FILTER RACK ACCESSORY 1 2 22 C 19 7 8 B D 1 1 2 3 1 2 A 22 21 1 2 All four sides 2 Max Thick Filter 3 4 1 2 3...

Page 9: ...10 47 64 PLENUM 12 1 2 FLOOR OPENING APPROX 1 2 CLEARANCE ALL AROUND FLOOR A AIR HANDLER WIDTH COMBUSTIBLE FLOOR BASE 1 1 APPROX 1 2 CLEARANCE ALL AROUND C FLOOR OPENING B PLENUM All dimensions are in inches They are subject to change without notice Certified dimensions will be provided upon request Floor Base Model Used with Dimensions A B C D 1FB1817 MV12B 19 9 18 0 14 9 16 9 1FB1821 MV16C 23 4 ...

Page 10: ...tic pressure From 0 6 to 1 0 static pressure CFM is reduced by 2 per 0 1 increase in static Operation on duct systems with greater than 1 0 w c external static pressure is not recommended NOTE At some settings LOW COOL and or LOW HEAT airflow may be lower than what is required to operate an airflow switch on certain models of electronic air cleaners Consult the instructions for the electronic air ...

Page 11: ... AIR CONDITIONING R R G Y W1 W2 C G W1 W2 Y C Y Y2 Y1 O HUM X L COM HUMIDISTAT THERMOSTAT AIR HANDLER BOARD 1 STAGE AIR CONDITIONING R R G Y W1 W2 C G W1 W2 Y C Y Y2 Y1 O HUM X L COM HUMIDISTAT MA SERIES Air Handler Control Wiring Typical A C with Electric Heat Applications CONTROL WIRING MV SERIES CONTROL WIRING MA Series Air Handler New UPG HP Systems Two Stage H P with York Guard VI Board Copel...

Page 12: ...to change without notice Printed in U S A 255427 YTG F 1006 Copyright by York International JCI 2006 All rights reserved Supersedes 255427 YTG E 0906 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...