York MC Installation Manual Download Page 3

841890-UIM-B-0612

3

TABLE 2: 

Dimensions - FC Coils

Models

Dimensions

 1

Refrigerant 

Connections 

2

Height

Width

Opening Widths

Line Size

A

B

C

D

Liquid

Vapor

FC18A

18

14 1/2

13 3/8

13 1/2

 3/8

 3/4

FC18B

18

17 1/2

16 3/8

16 1/2

FC24A

22

14 1/2

13 3/8

13 1/2

FC24B

22

17 1/2

16 3/8

16 1/2

FC30A

22

14 1/2

13 3/8

13 1/2

FC30B

22

17 1/2

16 3/8

16 1/2

FC32A

20

14 1/2

13 3/8

13 1/2

FC35B

20

17 1/2

16 3/8

16 1/2

FC35C

24 1/2

21

19 7/8

20

FC36A

24 1/2

14 1/2

13 3/8

13 1/2

7/8

FC36B

24 1/2

17 1/2

16 3/8

16 1/2

FC36C

24 1/2

21

19 7/8

20

FC37A

24 1/2

14 1/2

13 3/8

13 1/2

3/4

FC42B

28

17 1/2

16 3/8

16 1/2

7/8

FC42C

28

21

19 7/8

20

FC43B

24 1/2

17 1/2

16 3/8

16 1/2

FC43C

24 1/2

21

19 7/8

20

FC48C

28

21

19 7/8

20

FC48D

28

24 1/2

23 3/8

23 1/2

FC60C

28

21

19 7/8

20

FC60D

28

24 1/2

23 3/8

23 1/2

FC62D

32

24 1/2

23 3/8

23 1/2

FC64D

36

24 1/2

23 3/8

23 1/2

1. All dimensions are in inches.
2. Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

20

3/8”

(Opening)

B

C

3/4” Flange

A

21 1/2”

BOTTOM
OPENING
DIMENSIONS

D

20 1/4”

TABLE 3: 

Dimensions - PC Coils

Models

Dimensions

 1

Refrigerant 

Connections 

2

Height

Width

Opening Widths

Line Size

A

B

C

D

Liquid

Vapor

PC18A

17 3/4

14 1/2

13 3/8

13 1/2

 3/8

 3/4

PC18B

17    

17 1/2

16 3/8

16 1/2

PC24A

21 7/8

14 1/2

13 3/8

13 1/2

PC24B

21 3/8

17 1/2

16 3/8

16 1/2

PC30A

21 7/8

14 1/2

13 3/8

13 1/2

PC30B

21 3/8

17 1/2

16 3/8

16 1/2

PC32A

20    

14 1/2

13 3/8

13 1/2

PC35B

18 7/8

17 1/2

16 3/8

16 1/2

PC35C

18 3/4

21    

19 7/8

20    

PC36A

23 7/8

14 1/2

13 3/8

13 1/2

7/8

PC36B

23 1/8

17 1/2

16 3/8

16 1/2

PC36C

22 7/8

21    

19 7/8

20    

PC37A

23 7/8

14 1/2

13 3/8

13 1/2

3/4

PC42B

27 5/8

17 1/2

16 3/8

16 1/2

7/8

PC42C

27 1/8

21    

19 7/8

20    

PC43B

23 1/8

17 1/2

16 3/8

16 1/2

PC43C

22 5/8

21    

19 7/8

20    

PC48C

25 3/8

21    

19 7/8

20    

PC48D

24 5/8

24 1/2

23 3/8

23 1/2

PC60C

27 1/2

21    

19 7/8

20    

PC60D

26 7/8

24 1/2

23 3/8

23 1/2

1. All dimensions are in inches.
2. Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.

20

3/8”

(Opening)

B

C

(Opening)

12”

A

21 1/2”

BOTTOM
OPENING
DIMENSIONS

20 1/4”

D

Summary of Contents for MC

Page 1: ...hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION...

Page 2: ...MC Coils Only Primary Drain Secondary Drain Bottom Door Panel FIGURE 2 Component Location Coil PC Label Location Coil Access Panel Primary Drain Secondary Drain Bottom Door Panel Alternate Drain Locat...

Page 3: ...See York bulletin 690 01 AD1V for details 20 3 8 Opening B C 3 4 Flange A 21 1 2 BOTTOM OPENING DIMENSIONS D 20 1 4 TABLE 3 Dimensions PC Coils Models Dimensions 1 Refrigerant Connections 2 Height Wid...

Page 4: ...0 1350 42 3 1050 1350 3 1 2 1225 1575 43 3 1050 1350 3 1 2 1225 1575 48 3 1050 1350 3 1 2 1225 1575 4 1400 1800 60 62 64 4 1600 1800 5 1750 2250 For models that have factory installed TXV s take cauti...

Page 5: ...ns and Condensate Drain Connections One mounting plate is provided with the coils COIL FLANGE FOR DOWNFLOW AND HORIZONTAL LEFT KIT INSTALLATION The coils include removable flanges to allow proper fit...

Page 6: ...handled in one of several ways best suited to the installation Upflow horizontal or downflow applications may be used The vast majority of problems encountered with combination heating and cooling sys...

Page 7: ...n it should be piped to a loca tion that will give the occupant a visual warning that the primary drain is clogged If the secondary drain is not used it must be capped DO NOT use TeflonTM tape pipe do...

Page 8: ...il using a portable manometer and static pressure tips To prepare coil for static pressure drop measurements the system should have been recently operational in cooling mode Drill 2 holes one 3 after...

Page 9: ...TXV Bulb positioned correctly Is Bulb Insulated Is Equalizer Line connected FIGURE 16 Drain Traps Secondary Primary 3 Min Were the primary and secondary drains trapped correctly FIGURE 17 Location of...

Page 10: ...change without notice Published in U S A 841890 UIM B 0612 Copyright 2012 by Johnson Controls Inc All rights reserved Supersedes 841890 UIM A 0412 York International Corp 5005 York Drive Norman OK 73...

Reviews: